The MC106B is a Winsen catalytic flammable gas sensor measuring 0 to 100%LEL. It detects natural gas, LPG, coal gas, CH4 and C3H8.
Detection range0-100%LEL
Working current(mA)150±10
Storage Environment-25~+70℃ <95%RH
Detection Principlecatalytic combustion
Life span5 years
Linearity≤ 5%
Product overview
Overview. The Winsen MC106B is a catalytic flammable gas sensor. Its detection principle is catalytic combustion, with a measuring range of 0 to 100%LEL.
Main characteristics. Sensitivity is between 15 and 45 mV, linearity is 5% or less, response time (90%) is 10 s or less and recovery time is 30 s or less. The sensor provides linear output with fast response, good repeatability and selectivity. Its life span is 5 years.
Target gases. The MC106B detects combustible gases such as non-industrial natural gas, LPG, coal gas, CH4 and C3H8.
Power and environment. The sensor operates at 2.5 ±0.1 V with a working current of 150 ±10 mA. Working environment is -40 to +70 °C below 95%RH, and storage environment is -25 to +70 °C below 95%RH.
Package. The standard plastic encapsulation measures φ12×9.5.
Integration. The MC106B uses a test element and a compensation element forming two arms of a bridge. The bridge output voltage changes in proportion to gas concentration, while the compensation element corrects for temperature and humidity.
The MC106B is a Winsen catalytic flammable gas sensor measuring 0 to 100%LEL. It detects natural gas, LPG, coal gas, CH4 and C3H8.
Detection range0-100%LEL
Working current(mA)150±10
Storage Environment-25~+70℃ <95%RH
Detection Principlecatalytic combustion
Life span5 years
2. Datasheet extract (recorded values)
Parameter
Value
Characteristics
Bridge output voltage in linear, fast response, good repeatability and selectivity
Detection Principle
catalytic combustion
Detection range
0-100%LEL
Life span
5 years
Linearity
≤ 5%
Measuring range(%LEL)
0~100
Model
MC106B
Recovery Time (90%)
≤ 30s
Response time (90%)
≤ 10s
Sensitivity (mV)
15~45
Sensor Type
Catalytic type
Size
φ12×9.5
Standard Encapsulation
Plastic
Storage Environment
-25~+70℃ <95%RH
Target
Combustible gases such as non-industrial natural gas,LPG,coal gas,CH4,C3H8 and so on
Working Conditions
Working voltage:2.5±0.1V; Working current:150±10mA
Working current(mA)
150±10
Working Environment
-40~+70℃ <95%RH
Working Voltage (V)
2.5±0.1
Applications and use cases
Architectures in which MC106B can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
Associated system blocks
Air sensorsGateway
Need a complete solution?
Send a request for MC106B and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details