Fuel-cell type electrochemical sensor for measuring ozone (O3) concentration in industrial and environmental protection applications.
Pressure rangeStandard atmosphere pressure ±10%
Detection range0-10/100ppm,Max 200ppm
Measurement Range0~10/0~100ppm
Storage humidity15%~90%RH (no condensation)
Storage Temperature-20℃~50℃
Anticipated using life2 years(In air)
Product overview
Manufacturer and reference. The Winsen ME2-O3 is an electrochemical O3 ozone gas sensor for measuring ozone concentration.
Measurement principle. The sensor works on the fuel-cell electrochemical principle: electrochemical oxidation of ozone on the working electrode produces a current proportional to the gas concentration, following Faraday's law. The concentration is derived from this current measurement.
Main characteristics. Measurement range 0-10/0-100 ppm, maximum detecting concentration 200 ppm, resolution ≤0.02 ppm and sensitivity ≥30 nA/ppm. T90 response time ≤120 s, repeatability below 5% of output value and stability below 2% per month. Zero drift (-20 to 40 °C) ≤0.2 ppm and linear output.
Power and environment. Standard atmosphere pressure ±10%. Recommended load resistance 200 Ω. Storage temperature -20 to 50 °C and storage humidity 15% to 90% RH without condensation. Anticipated using life 2 years in air.
Typical uses. Measurement of ozone concentration in industrial and environmental protection applications.
Integration. Size φ20 × 16.4. Low consumption, good anti-interference ability, and excellent repeatability and stability.
Fuel-cell type electrochemical sensor for measuring ozone (O3) concentration in industrial and environmental protection applications.
Pressure rangeStandard atmosphere pressure ±10%
Detection range0-10/100ppm,Max 200ppm
Measurement Range0~10/0~100ppm
Storage humidity15%~90%RH (no condensation)
Storage Temperature-20℃~50℃
2. Datasheet extract (recorded values)
Parameter
Value
Pressure range
Standard atmosphere pressure ±10%
Anticipated using life
2 years(In air)
Characteristics
Use for industrial and environmental protection fields
Detection Gas
O3
Detection Principle
Electrochemical
Detection range
0-10/100ppm,Max 200ppm
Load Resistance
200Ω (recommended)
Max detecting concentration
200ppm
Measurement Range
0~10/0~100ppm
Model
ME2-O3
Output Linearity
linear
Repeatability
<5% output value
Resolution ratio
≤ 0.02ppm
Response Time (T90)
≤ 120S
Sensitivity
≥ 30nA/ppm
Size
φ20×16.4
Stability (/month)
<2%
Storage humidity
15%~90%RH (no condensation)
Storage Temperature
-20℃~50℃
Target
O3
Working Conditions
Resolution ratio ≤0.02ppm; Response time<120s; Anticipated using life 2 years
Zero drift (-20~40℃)
≤ 0.2ppm
Applications and use cases
Architectures in which ME2-O3 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
Associated system blocks
Air sensorsGateway
Need a complete solution?
Send a request for ME2-O3 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details