The Winsen ME3-O3 electrochemical sensor measures ozone (O3) concentration by amperometric detection. It is intended for industrial and environmental protection gas detection applications.
Pressure rangeStandard atmosphere pressure±10%
Detection range0-10/20ppm, Max 50/100ppm
Measurement Range0~10ppm
Storage humidity15﹪~90﹪RH
Storage Temperature-20℃~50℃
Anticipated using life2years(In air)
Product overview
Overview. The Winsen ME3-O3 is an electrochemical gas sensor for ozone (O3) detection. It measures gas concentration from the current produced by electrochemical oxidation of the target gas on the working electrode inside the electrolytic cell, this current being proportional to concentration according to Faraday's law.
Main characteristics. The measurement range is 0 to 10 ppm, with a detection range of 0 to 10/20 ppm and a maximum detecting concentration of 50 ppm. Resolution is 0.05 ppm and sensitivity is (1.2 ± 0.3) µA/ppm. The output is linear, the T90 response time is at most 120 s, repeatability is below 5% of the output value and monthly stability is below 2%. Zero drift is at most 0.2 ppm between -20 and 40 °C. Anticipated service life is 2 years in air.
Power and environment. Bias voltage is 0 mV and the recommended load resistance is 10 Ω. The sensor can be stored between -20 °C and 50 °C, at a storage humidity of 15% to 90% RH. Its size is φ20 × 16.4. It offers low consumption and good anti-interference ability.
Typical uses. The ME3-O3 is designed for ozone detection in industrial and environmental protection fields. A humidity between 15% and 90% RH, without condensation, is required to preserve the sensor's life.
Integration. The sensor can be integrated into a measurement system using the recommended load resistance. It is available on quotation from Atlas Electronics.
The Winsen ME3-O3 electrochemical sensor measures ozone (O3) concentration by amperometric detection. It is intended for industrial and environmental protection gas detection applications.
Pressure rangeStandard atmosphere pressure±10%
Detection range0-10/20ppm, Max 50/100ppm
Measurement Range0~10ppm
Storage humidity15﹪~90﹪RH
Storage Temperature-20℃~50℃
2. Datasheet extract (recorded values)
Parameter
Value
Pressure range
Standard atmosphere pressure±10%
Anticipated using life
2years(In air)
Bias voltage
0mV
Characteristics
Use for O3 detection in industrial and environmental protection fields
Detection Gas
O3
Detection Principle
Electrochemical
Detection range
0-10/20ppm, Max 50/100ppm
Load Resistance
10Ω (recommended)
Max detecting concentration
50ppm
Measurement Range
0~10ppm
Model
ME3-O3
Output Linearity
linear
Repeatability
<5﹪output value
Resolution ratio
0.05ppm
Response Time (T90)
≤ 120S
Sensitivity
(1.2±0.3)µA/ppm
Size
φ20×16.4
Stability (/month)
<2﹪
Storage humidity
15﹪~90﹪RH
Storage Temperature
-20℃~50℃
Target
O3
Working Conditions
Resolution ratio 0.05ppm; Response time≤120s; Anticipated using life 2 years
Zero drift (-20~40℃)
≤ 0.2ppm
Applications and use cases
Architectures in which ME3-O3 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
Associated system blocks
Air sensorsGateway
Need a complete solution?
Send a request for ME3-O3 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details