Winsen ME3-C2H4 electrochemical sensor for ethylene (C2H4) detection in industrial and environmental protection applications, with a 0-100 ppm measurement range.
Pressure rangestandard atmosphere ±10%
Humidity range15%—90%RH
Detection range0-100ppm, Max 200ppm
Max Range200ppm
Tem. range-20°C-50°C
Anticipated using life2 years in air
Product overview
Overview. The Winsen ME3-C2H4 electrochemical gas sensor is a gas detector for measuring ethylene (C2H4) concentration. It relies on an electrochemical oxidation process at the working electrode of an electrolytic cell: the current produced is directly proportional to the target gas concentration, following Faraday's law.
Main characteristics. Detection range of 0-100 ppm, with a maximum of 200 ppm, and a resolution of 0.5 ppm. Sensitivity is (0.070±0.015) µA/ppm, reproducibility is less than 2% of signal output and monthly stability is less than 5%. Response time T90 is less than or equal to 20 s. Zero drift is 10 ppm between -20 °C and 40 °C. The sensor offers linearity output, low consumption and good anti-interference ability. Size: φ20×16.4.
Operating conditions. Temperature range from -20 °C to 50 °C and humidity range from 15% to 90% RH without condensation. Pressure range is standard atmosphere ±10%. Anticipated service life is 2 years in air; the working conditions specify 3 years.
Typical uses. Ethylene detection in industrial and environmental protection applications.
Winsen ME3-C2H4 electrochemical sensor for ethylene (C2H4) detection in industrial and environmental protection applications, with a 0-100 ppm measurement range.
Pressure rangestandard atmosphere ±10%
Humidity range15%—90%RH
Detection range0-100ppm, Max 200ppm
Max Range200ppm
Tem. range-20°C-50°C
2. Datasheet extract (recorded values)
Parameter
Value
Pressure range
standard atmosphere ±10%
Humidity range
15%—90%RH
Anticipated using life
2 years in air
Bias voltage
0mV
Characteristics
Use for ethylene detection in industrial and environmental protection fields
Detection Gas
C2H4
Detection Principle
Electrochemical
Detection range
0-100ppm, Max 200ppm
Load Resistance
10&Omega
Max Range
200ppm
Model
ME3-C2H4
Output
Linearity output
Reproducibility
<2% of signal output
Resolution
0.5ppm
Response Time (T90)
≤ 20S
Sensitivity
(0.070±0.015)µA/ppm
Size
φ20×16.4
Stability per month
<5﹪
Target
C2H4
Tem. range
-20°C-50°C
Working Conditions
Resolution ratio 0.5ppm; Response time<20s; Anticipated using life 3 years
Zero drift(-20°C-40°C)
10ppm
Applications and use cases
Architectures in which ME3-C2H4 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
Associated system blocks
Air sensorsGateway
Need a complete solution?
Send a request for ME3-C2H4 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details