Winsen ME4-CO-E4 electrochemical carbon monoxide (CO) gas sensor for urban air, environmental and industrial emission monitoring.
Temperature range-30℃~50℃
Pressure range80-120kPa
Humidity range15%~90% RH
Detection range0-1000ppm, Max 2000ppm
Max Range2000ppm
Detection GasCarbon monoxide (CO)
Product overview
Overview. The Winsen ME4-CO-E4 is an electrochemical carbon monoxide gas sensor of the constant potential electrolysis type. An oxidation-reduction reaction between carbon monoxide and oxygen generates a current proportional to the target gas concentration, which is measured to determine the concentration. A fourth auxiliary electrode compensates the zero current.
Main characteristics. Detection range of 0 to 1000 ppm, maximum 2000 ppm, resolution below 10 ppb and sensitivity of 0.3 to 0.5 µA/ppm. T90 response time is below 30 s, stability is below 10% per month and zero drift is below ±100 ppb between -20 and 40 °C. The output is linear.
Operating conditions. Temperature range from -30 °C to 50 °C, pressure range 80 to 120 kPa and humidity 15% to 90% RH. Recommended load resistance 33 to 100 Ω. Size φ32 × 14.5 mm. Anticipated service life of 2 years in air.
Typical uses. Urban atmospheric monitoring, enterprise environmental monitoring, unorganized emission gas monitoring in factories, emergency monitoring and environmental assessment.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for ME4-CO-E4, with where it comes from. Use the filters to find one quickly.
All specifications (20)
Characteristic
Value
Pressure range
80-120kPa
Humidity range
15%~90% RH
Characteristics
Urban atmosphere and enterprise environmental monitoring, unorganized emission pollution gas monitoring in factories, emergency monitoring, environmental assessment and monitoring
Detection Gas
Carbon monoxide (CO)
Detection Principle
Electrochemical
Detection range
0-1000ppm, Max 2000ppm
Life span
2 years (in air)
Load resistance(recommended)
33-100Ω (Recommended)
Max Range
2000ppm
Model
ME4-CO-E4
Output Linearity
Linear
Resolution
<10ppb
Response Time (T90)
< 30S
Sensitivity
0.3~0.5µA/ppm
Size
φ32×14.5
Stability (/month)
<10%
Target
CO
Temperature range
-30℃~50℃
Working Conditions
Resolution ratio <10ppb; Response time<30s; Anticipated using life 2 years
Zero drift (-20~40℃)
<±100ppb
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for ME4-CO-E4. For a missing document or a specific revision, our experts send it to you.
Winsen ME4-CO-E4 electrochemical carbon monoxide (CO) gas sensor for urban air, environmental and industrial emission monitoring.
Temperature range-30℃~50℃
Pressure range80-120kPa
Humidity range15%~90% RH
Detection range0-1000ppm, Max 2000ppm
Max Range2000ppm
2. Datasheet extract (recorded values)
Parameter
Value
Pressure range
80-120kPa
Humidity range
15%~90% RH
Characteristics
Urban atmosphere and enterprise environmental monitoring, unorganized emission pollution gas monitoring in factories, emergency monitoring, environmental assessment and monitoring
Detection Gas
Carbon monoxide (CO)
Detection Principle
Electrochemical
Detection range
0-1000ppm, Max 2000ppm
Life span
2 years (in air)
Load resistance(recommended)
33-100Ω (Recommended)
Max Range
2000ppm
Model
ME4-CO-E4
Output Linearity
Linear
Resolution
<10ppb
Response Time (T90)
< 30S
Sensitivity
0.3~0.5µA/ppm
Size
φ32×14.5
Stability (/month)
<10%
Target
CO
Temperature range
-30℃~50℃
Working Conditions
Resolution ratio <10ppb; Response time<30s; Anticipated using life 2 years
Zero drift (-20~40℃)
<±100ppb
Applications and use cases
Architectures in which ME4-CO-E4 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
Associated system blocks
Air sensorsGateway
Need a complete solution?
Send a request for ME4-CO-E4 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productWinsen
ME4-CO-E4
Electrochemical carbon monoxide CO gas sensor 0-1000 ppm
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details