Winsen ME3-CO electrochemical sensor measuring carbon monoxide (CO) concentration from 0 to 1000 ppm, for leak detection in industrial sites and environmental protection applications.
Pressure rangeStandard atmospheric pressure ±10﹪
Detection range0-1000ppm, Max 2000ppm
Measurement Range0~1000ppm
Storage humidity15%~90% RH
Storage Temperature-20℃~50℃
Anticipated using life3 years (in air)
Product overview
Winsen ME3-CO gas sensor. The Winsen ME3-CO electrochemical sensor measures carbon monoxide (CO) concentration by detecting the current produced by the electrochemical oxidation of the target gas on the working electrode. This current is proportional to the concentration according to Faraday's law.
Main characteristics. Measurement range 0 to 1000 ppm, maximum detection concentration 2000 ppm, resolution 0.5 ppm, sensitivity (0.070±0.015) µA/ppm and linear output. T90 response time is under 20 s, stability is under 5% per month and repeatability is under 2% of the output value. Zero drift is at most 10 ppm between -20 and 40 °C. Size φ20×16.4.
Power and environment. Bias voltage 0 mV, recommended load resistance 10 Ω, standard atmospheric pressure ±10%. Storage temperature -20 to 50 °C and storage humidity 15% to 90% RH. Anticipated service life of 3 years in air.
Typical uses. Detection of CO leaks in industrial sites such as petroleum and petrochemical, metallurgy and mining, as well as environmental protection applications.
Integration. Low-consumption sensor with good anti-interference ability, high precision and high sensitivity. Available on quotation from Atlas Electronics.
Winsen ME3-CO electrochemical sensor measuring carbon monoxide (CO) concentration from 0 to 1000 ppm, for leak detection in industrial sites and environmental protection applications.
Pressure rangeStandard atmospheric pressure ±10﹪
Detection range0-1000ppm, Max 2000ppm
Measurement Range0~1000ppm
Storage humidity15%~90% RH
Storage Temperature-20℃~50℃
2. Datasheet extract (recorded values)
Parameter
Value
Pressure range
Standard atmospheric pressure ±10﹪
Anticipated using life
3 years (in air)
Bias voltage
0mV
Characteristics
Petroleum and petrochemical, metallurgy, mining and other industrial sites and environmental protection fields
Detection Gas
Carbon Monoxide (CO)
Detection Principle
Electrochemical
Detection range
0-1000ppm, Max 2000ppm
Load resistance(recommend)
10&Omega
Max detecting concentration
2000ppm
Measurement Range
0~1000ppm
Model
ME3-CO
Output Linearity
Linear
Repeatability
<2% output value
Resolution ratio
0.5ppm
Response Time (T90)
<20S
Sensitivity
(0.070±0.015) µA/ppm
Size
φ20×16.4
Stability (/month)
<5%
Storage humidity
15%~90% RH
Storage Temperature
-20℃~50℃
Target
CO
Working Conditions
Resolution ratio 0.5ppm; Response time<20s; Anticipated using life 3 years
Zero drift (-20~40℃)
≤ 10ppm
Applications and use cases
Architectures in which ME3-CO can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
Associated system blocks
Air sensorsGateway
Need a complete solution?
Send a request for ME3-CO and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Urban atmosphere and enterprise environmental monitoring, unorganized emission pollution gas monitoring in factories, emergency monitoring, environmental assessment and monitoring
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.