The Winsen ME4-CO electrochemical sensor measures carbon monoxide (CO) concentration in air, from 0 to 1000 ppm, for gas detection in industrial and environmental protection applications.
Temperature range-20℃~50℃
Pressure rangeStandard atmospheric pressure ±10%
Humidity range15%~90% RH
Detection range0-1000ppm, Max 1500ppm
Max Range1500ppm
Bias voltage0mV
Product overview
Overview. The Winsen ME4-CO carbon monoxide gas sensor is a constant potential electrolysis type electrochemical sensor. Oxidation-reduction reactions of carbon monoxide and oxygen take place on the working electrode and the counter electrode; the generated current is proportional to the carbon monoxide concentration.
Main characteristics. Detection range of 0-1000 ppm (maximum 1500 ppm), resolution of 1 ppm, sensitivity of (0.080±0.02) µA/ppm, linear output, repeatability below 2% of output and stability below 5% per month. Response time T90 is at most 25 s and zero drift is 9 ppm between -20 and 40 °C.
Power and environment. Operating temperature range of -20 to 50 °C, humidity range of 15% to 90% RH, standard atmospheric pressure ±10%. Bias voltage of 0 mV and recommended load resistance of 10 Ω. Size φ32 × 14.5 mm. Life span of 2 years in air.
Typical uses. Carbon monoxide detection on industrial sites such as petroleum and petrochemical plants, metallurgy and mining, and in environmental protection fields.
The Winsen ME4-CO electrochemical sensor measures carbon monoxide (CO) concentration in air, from 0 to 1000 ppm, for gas detection in industrial and environmental protection applications.
Temperature range-20℃~50℃
Pressure rangeStandard atmospheric pressure ±10%
Humidity range15%~90% RH
Detection range0-1000ppm, Max 1500ppm
Max Range1500ppm
2. Datasheet extract (recorded values)
Parameter
Value
Pressure range
Standard atmospheric pressure ±10%
Humidity range
15%~90% RH
Bias voltage
0mV
Characteristics
Petroleum and petrochemical, metallurgy, mining and other industrial sites and environmental protection fields
Detection Gas
Carbon monoxide (CO)
Detection Principle
Electrochemical
Detection range
0-1000ppm, Max 1500ppm
Life span
2 years (in air)
Load resistance(recommended)
10&Omega
Max Range
1500ppm
Model
ME4-CO
Output Linearity
Linear
Repeatability
<2% Output
Resolution
1ppm
Response Time (T90)
≤ 25S
Sensitivity
(0.080±0.02) µA/ppm
Size
φ32×14.5
Stability (/month)
<5%
Target
CO
Temperature range
-20℃~50℃
Working Conditions
Resolution ratio 1ppm; Response time≤25s; Anticipated using life 2 years
Zero drift (-20~40℃)
9ppm
Applications and use cases
Architectures in which ME4-CO can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
Associated system blocks
Air sensorsGateway
Need a complete solution?
Send a request for ME4-CO and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Urban atmosphere and enterprise environmental monitoring, unorganized emission pollution gas monitoring in factories, emergency monitoring, environmental assessment and monitoring
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details