MW-O101
Galvanic dissolved oxygen sensor for water quality

- Temperature range
- 0~40℃
- Detection range
- 0~20 mg/L
- Measure range
- 0~20 mg/L
- Interface
- 2 connection wires
Galvanic dissolved oxygen sensor for water quality
MW-O101 galvanic dissolved oxygen sensor for water quality measurement in laboratory, aquaculture and environmental applications, with a range of 0 to 20 mg/L.
Overview. The Winsen MW-O101 is a galvanic battery type sensor for measuring dissolved oxygen in solutions. Oxygen molecules pass through the sensor's selective membrane and generate a current proportional to the dissolved oxygen concentration.
Main characteristics. Measurement range 0 to 20 mg/L, measurement error less than or equal to ±0.1 mg/L, repeatability less than or equal to ±0.10 mg/L, stability ±0.03 mg/L, minimum graduation value 0.01 mg/L and sensitivity 0.6-1 mV/mg/L (O2). Response time T90 is less than 20 s.
Output and interface. Current output of 0.93 µA to 1.33 µA, output impedance about 15 kΩ, 2 connection wires. The sensor has no temperature compensation.
Power and environment. Operating temperature range 0 to 40 °C. Low power consumption. No need to replace the breathable membrane or the electrolyte.
Typical uses. Dissolved oxygen measurement in laboratory research, aquaculture and environmental protection.
Integration. The sensor is delivered uncalibrated; ageing and calibration are recommended once stable, according to the programme and conditions of use of the whole device. Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for MW-O101, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Response time | <20 s |
| Characteristics | Low power consumption, high precision, linear output, no need to replace the breathable membrane, no need to replace the electrolyte. |
| Detection Principle | It is a galvanic battery type dissolved oxygen water quality detection sensor. |
| Detection range | 0~20 mg/L |
| Interface | 2 connection wires |
| Measure range | 0~20 mg/L |
| Measurement Error | ≤ ±0.1 mg/L |
| Minimum graduation value | 0.01 mg/L |
| Model | MW-O101 |
| Output | 0.93 μ A -1.33 μ A |
| Output Impedance | About 15 K&Omega |
| Repeatability | ≤ ±0.10 mg/L |
| Resolution and accuracy | Minimum graduation value 0.01 mg/L; Sensitivity 0.6-1 mV/mg/L(O2) |
| Response Time (T90) | <20 s |
| Sensitivity | 0.6-1 mV/mg/L(O2) |
| Stability | ±0.03 mg/L |
| Target | Solution |
| Temperature Compensation | without |
| Temperature range | 0~40℃ |
| Zero Error | ≤ 0.1 mg/L |
| Zero point output (oxygen-free water) | <0.06 μ A (2% Na2SO3, 22℃) |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for MW-O101. For a missing document or a specific revision, our experts send it to you.
MW-O101 galvanic dissolved oxygen sensor for water quality measurement in laboratory, aquaculture and environmental applications, with a range of 0 to 20 mg/L.
| Parameter | Value |
|---|---|
| Response time | <20 s |
| Characteristics | Low power consumption, high precision, linear output, no need to replace the breathable membrane, no need to replace the electrolyte. |
| Detection Principle | It is a galvanic battery type dissolved oxygen water quality detection sensor. |
| Detection range | 0~20 mg/L |
| Interface | 2 connection wires |
| Measure range | 0~20 mg/L |
| Measurement Error | ≤ ±0.1 mg/L |
| Minimum graduation value | 0.01 mg/L |
| Model | MW-O101 |
| Output | 0.93 μ A -1.33 μ A |
| Output Impedance | About 15 K&Omega |
| Repeatability | ≤ ±0.10 mg/L |
| Resolution and accuracy | Minimum graduation value 0.01 mg/L; Sensitivity 0.6-1 mV/mg/L(O2) |
| Response Time (T90) | <20 s |
| Sensitivity | 0.6-1 mV/mg/L(O2) |
| Stability | ±0.03 mg/L |
| Target | Solution |
| Temperature Compensation | without |
| Temperature range | 0~40℃ |
| Zero Error | ≤ 0.1 mg/L |
| Zero point output (oxygen-free water) | <0.06 μ A (2% Na2SO3, 22℃) |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Galvanic dissolved oxygen sensor for water quality

dissolved oxygen water quality detection sensor

SUP-DO7019 Liquid analyzing meter dissolved oxygen transmitter

RS485 MODBUS Dissolved Oxygen Sensor, Fluorescence DO Meter, Water Quality Monitoring

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | MW-O101 |
| Manufacturer | Winsen |
Dissolved Oxygen Sensors
RS485 Modbus Dissolved Oxygen Sensor, Fluorescence Method
Price on request
Dissolved Oxygen Sensors
Portable digital dissolved oxygen meter · Ref. : FT-SS8
Price on request
Dissolved Oxygen Sensors
Online dissolved oxygen controller for wastewater
Price on request
Dissolved Oxygen Sensors
Online optical dissolved oxygen sensor with transmitter
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details