ZE07-CH2O
Electrochemical formaldehyde CH2O sensor module 0-5 ppm

- Operating temperature
- 0℃~50℃
- Detection range
- 0~5ppm
- Storage Temp
- 0℃~50℃
- Response time
- ≤ 60s
Electrochemical formaldehyde CH2O sensor module 0-5 ppm
Winsen ZE07-CH2O electrochemical sensor module for measuring formaldehyde (HCHO) in air over a 0 to 5 ppm range, for portable detectors and air-quality monitoring systems.
Overview. The Winsen ZE07-CH2O is a miniaturised electrochemical formaldehyde (HCHO, CH2O) sensor module. It measures CH2O concentration in air over a range of 0 to 5 ppm with a resolution of 0.01 ppm, based on the electrochemical principle.
Main characteristics. The sensor offers high sensitivity and resolution as well as good stability. Its response time is less than or equal to 60 s and its warm-up time less than or equal to 3 minutes. Its working life is 2 years in air.
Outputs and interfaces. The output data is DAC type, with a standard voltage output of 0.4 to 2 V.
Power and environment. The working voltage is between 3.7 V and 9 V, with no reverse-connection protection. The module operates between 0 °C and 50 °C, storage temperature being the same, and between 15% and 90% RH without condensation.
Selectivity. The sensor is affected by interfering gases such as alcohol and CO.
Typical uses. Portable detectors, air-quality monitors, air fresheners, fresh air ventilation systems, air conditioning and smart home devices.
Integration. The module design must take into account the voltage, temperature and humidity ranges stated above. A quotation can be requested from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for ZE07-CH2O, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Response time | ≤ 60s |
| Operating temperature | 0℃~50℃ |
| Characteristics | High sensitivity & resolution& Good stability |
| Detection Principle | Electrochemical,Modle |
| Detection range | 0~5ppm |
| Interference Gas | Alcohol, CO &etc. |
| Model | ZE07-CH2O |
| Model No. | ZE07-CH2O |
| Operating Hum | 15%RH-90%RH (No condensation) |
| Output data | DAC(0.4~2V standard voltage output) |
| Resolution | 0.01ppm |
| Resume Time | ≤ 60s |
| Storage Temp | 0℃~50℃ |
| Target | CH2O, HCHO, Formaldehyde |
| Target gas | CH2O |
| Warm-Up Time | ≤ 3 minutes |
| Working Life | 2 years(in air) |
| Working voltage | 3.7V~9V (No voltage reverse connect protection) |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for ZE07-CH2O. For a missing document or a specific revision, our experts send it to you.
Winsen ZE07-CH2O electrochemical sensor module for measuring formaldehyde (HCHO) in air over a 0 to 5 ppm range, for portable detectors and air-quality monitoring systems.
| Parameter | Value |
|---|---|
| Response time | ≤ 60s |
| Operating temperature | 0℃~50℃ |
| Characteristics | High sensitivity & resolution& Good stability |
| Detection Principle | Electrochemical,Modle |
| Detection range | 0~5ppm |
| Interference Gas | Alcohol, CO &etc. |
| Model | ZE07-CH2O |
| Model No. | ZE07-CH2O |
| Operating Hum | 15%RH-90%RH (No condensation) |
| Output data | DAC(0.4~2V standard voltage output) |
| Resolution | 0.01ppm |
| Resume Time | ≤ 60s |
| Storage Temp | 0℃~50℃ |
| Target | CH2O, HCHO, Formaldehyde |
| Target gas | CH2O |
| Warm-Up Time | ≤ 3 minutes |
| Working Life | 2 years(in air) |
| Working voltage | 3.7V~9V (No voltage reverse connect protection) |
Points to check before using ZE07-CH2O in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Working voltage | 3.7V~9V (No voltage reverse connect protection) |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of ZE07-CH2O can answer. A question is not asked when nothing is recorded to answer it.
0℃~50℃ (source: Operating temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Electrochemical formaldehyde CH2O sensor module 0-5 ppm

Electrochemical HCHO Formaldehyde Sensor Module

Electrochemical HCHO Formaldehyde Sensor

Explosion-proof Formaldehyde Detector Gas Sensor

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | ZE07-CH2O |
| Manufacturer | Winsen |
Formaldehyde Sensors
Digital formaldehyde (HCHO) sensor with I²C interface · Ref. : IAGM1
Price on request
Formaldehyde Sensors
Formaldehyde MEMS sensor, breakout, 0-3 ppm range · Ref. : SEN0563
Price on request
Formaldehyde Sensors
4-in-1 Indoor Air Quality Monitor with Touchscreen, HCHO and TVOC · Ref. : SFD-02
Price on request
Formaldehyde Sensors
Electrochemical formaldehyde CH2O sensor, UART output · Ref. : ZE510-CH2O
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details