The Winsen ZE12A electrochemical detection module measures carbon monoxide, sulphur dioxide, nitrogen dioxide and ozone. It is intended for environmental monitoring and portable gas detectors.
Storage Temperature0~20℃
Response time≤ 120 Sec
Detection PrincipleModule, electrochemical
DimensionΦ 39×44 mm
Life span2 years (in air)
ModelZE12A
Product overview
Overview. The Winsen ZE12A is an electrochemical gas detection module measuring CO (0-10 ppm), SO2 (0-1 ppm), NO2 (0-1 ppm) and O3 (0-1 ppm), with a resolution of 10 ppb or less. A built-in temperature sensor provides temperature compensation.
Main characteristics. Response time of 120 s or less, service life of 2 years in air, operating voltage of 5.0 ± 0.1 V DC, weight of 75 g and dimensions Φ39 × 44 mm.
Interfaces and outputs. UART output and standard DAC analog voltage output of 0.4 to 2 V, allowing digital or analog integration depending on the board architecture.
Environment. Operating temperature range of -20 to 50 °C, storage temperature of 0 to 20 °C.
Typical uses. Urban atmospheric monitoring, enterprise environmental monitoring, unorganised emission monitoring in factory areas, emergency monitoring, portable gas detectors and various equipment for detecting toxic or hazardous gases.
Integration. The manufacturer states that the sensor has no sleep mode, which can be set in the program if needed. The module is calibrated before shipment, but ageing and recalibration are recommended after storage and transport, depending on the application. Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for ZE12A, with where it comes from. Use the filters to find one quickly.
All specifications (18)
Characteristic
Value
Response time
≤ 120 Sec
Characteristics
City atmospheric environmental monitoring, enterprise environment monitoring, Factory area unorganized emission monitoring, emergency monitoring, environment evaluation monitoring, Portable gas detector, various gas detection equipment and smart home ap
Detection Principle
Module, electrochemical
Detection range
CO (0-10ppm), SO2 (0-1ppm), NO2 (0-1ppm), O3 (0-1ppm)
Dimension
Φ 39×44 mm
Life span
2 years (in air)
Model
ZE12A
Model No.
ZE12A
Operating Environment
Temperature: -20~50℃
Output data
DAC (0.4~2V) standard voltage signal
Resolution
≤ 10ppb
Size
Φ39×44 mm
Storage Temperature
0~20℃
Target
CO, SO2, NO2, O3
Target gas
CO, SO2, NO2,O3, H2S
Weight
75g
Working Conditions
Resolution≤10ppb; Response time≤120S; Working life 2 year (Normal in the air)
Working voltage
DC 5.0±0.1V
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for ZE12A. For a missing document or a specific revision, our experts send it to you.
The Winsen ZE12A electrochemical detection module measures carbon monoxide, sulphur dioxide, nitrogen dioxide and ozone. It is intended for environmental monitoring and portable gas detectors.
Storage Temperature0~20℃
Response time≤ 120 Sec
Detection PrincipleModule, electrochemical
DimensionΦ 39×44 mm
Life span2 years (in air)
2. Datasheet extract (recorded values)
Parameter
Value
Response time
≤ 120 Sec
Characteristics
City atmospheric environmental monitoring, enterprise environment monitoring, Factory area unorganized emission monitoring, emergency monitoring, environment evaluation monitoring, Portable gas detector, various gas detection equipment and smart home ap
Detection Principle
Module, electrochemical
Detection range
CO (0-10ppm), SO2 (0-1ppm), NO2 (0-1ppm), O3 (0-1ppm)
Dimension
Φ 39×44 mm
Life span
2 years (in air)
Model
ZE12A
Model No.
ZE12A
Operating Environment
Temperature: -20~50℃
Output data
DAC (0.4~2V) standard voltage signal
Resolution
≤ 10ppb
Size
Φ39×44 mm
Storage Temperature
0~20℃
Target
CO, SO2, NO2, O3
Target gas
CO, SO2, NO2,O3, H2S
Weight
75g
Working Conditions
Resolution≤10ppb; Response time≤120S; Working life 2 year (Normal in the air)
Working voltage
DC 5.0±0.1V
Applications and use cases
Architectures in which ZE12A can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
Associated system blocks
Air sensorsGateway
Need a complete solution?
Send a request for ZE12A and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productWinsen
ZE12A
Electrochemical gas detection module CO, SO2, NO2, O3
Urban atmosphere and enterprise environmental monitoring, unorganized emission pollution gas monitoring in factories, emergency monitoring, environmental assessment and monitoring
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details