Product overview
Overview. The Winsen ZH09 laser dust sensor is a module that detects airborne particulate matter using the laser scattering principle. It measures PM1.0, PM2.5 and PM10 particles and provides real-time, consistent readings.
Main characteristics. The T90 response time is below 45 s, with a 1 s detection interval and a 30 s preheating time. The effective range extends from 0 to 1000 µg/m³. Accuracy is ±15 µg/m³ from 0 to 100 µg/m³ and ±15% of reading from 101 to 1000 µg/m³, under test conditions of 25 ± 2 °C and 50 ± 10% RH. The minimum particle diameter resolution is 0.3 µm.
Interfaces and power. The output is UART TTL at 3.3 V level. The sensor operates at 4.9 V to 5.5 V DC, with a working current below 120 mA and a dormancy current below 20 mA.
Environment and dimensions. The module operates between −10 and 60 °C and between 0 and 80% RH without condensation, and can be stored between −30 and 70 °C. Its dimensions are 47×37×12.2 mm (L×W×H) for a weight below 30 g. The MTTF is greater than 10,000 h in continuous operation.
Typical uses and integration. Its small size allows integration into air purifiers, ventilation systems, air conditioners, air quality monitoring equipment and smart home devices. Its UART output facilitates connection to a microcontroller or data acquisition system.