OPD700
Fluorescence Dissolved Oxygen Sensor with RS485 Modbus-RTU Output

- Accuracy
- Dissolved Oxygen: ±0.3 mg/L
- Communication
- RS485 Modbus-RTU
- Power supply
- 6~12VDC
- Saturation
- 0~200% (Resolution: ±0.01%)
Fluorescence Dissolved Oxygen Sensor with RS485 Modbus-RTU Output
Fluorescence dissolved oxygen sensor for continuous oxygen measurement in fresh and seawater, notably for water treatment and aquaculture.
Overview. The Daruifuno OPD700 fluorescence dissolved oxygen sensor is an instrument designed to monitor dissolved oxygen levels in various aquatic environments. Its fluorescence method provides precise and stable oxygen readings for water quality control.
Measurement characteristics. Dissolved oxygen is measured from 0.00 to 20.00 mg/L with a resolution of ±0.01 mg/L and an accuracy of ±0.3 mg/L. Saturation ranges from 0 to 200% (resolution ±0.01%), with an accuracy of ±3%. Temperature is measured from 0 to 45°C (resolution ±0.01°C) with an accuracy of ±0.5°C.
Construction. The titanium alloy body provides high corrosion resistance. The sensor measures Φ22 × 155 mm, supports a working pressure of 6 Bar or less and installs through an M22 × 1.5 mm threaded connection.
Connectivity and power. The sensor communicates over RS485 using the Modbus-RTU protocol and runs on a 6 to 12 VDC supply, allowing integration into water quality monitoring systems.
Typical uses. Freshwater and seawater treatment, and aquaculture systems, where dissolved oxygen monitoring supports aquatic life and effective water treatment.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for OPD700, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accuracy | Dissolved Oxygen: ±0.3 mg/L |
| Body Material | Titanium Alloy for high corrosion resistance |
| Communication | RS485 Modbus-RTU |
| Installation | M22*1.5 mm threaded connection for easy installation |
| Measurement Range | Dissolved Oxygen: 0.00~20.00 mg/L (Resolution: ±0.01 mg/L) |
| Power supply | 6~12VDC |
| Saturation | 0~200% (Resolution: ±0.01%) |
| Size | Φ22*155 mm |
| Temperature | 0~45°C (Resolution: ±0.01°C) |
| We will contact you immediately | Fill in more information so that we can get in touch with you faster |
| Working Pressure | ≤6 Bar |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for OPD700. For a missing document or a specific revision, our experts send it to you.
Fluorescence dissolved oxygen sensor for continuous oxygen measurement in fresh and seawater, notably for water treatment and aquaculture.
| Parameter | Value |
|---|---|
| Accuracy | Dissolved Oxygen: ±0.3 mg/L |
| Body Material | Titanium Alloy for high corrosion resistance |
| Communication | RS485 Modbus-RTU |
| Installation | M22*1.5 mm threaded connection for easy installation |
| Measurement Range | Dissolved Oxygen: 0.00~20.00 mg/L (Resolution: ±0.01 mg/L) |
| Power supply | 6~12VDC |
| Saturation | 0~200% (Resolution: ±0.01%) |
| Size | Φ22*155 mm |
| Temperature | 0~45°C (Resolution: ±0.01°C) |
| We will contact you immediately | Fill in more information so that we can get in touch with you faster |
| Working Pressure | ≤6 Bar |
Answers to the questions that the recorded characteristics of OPD700 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication": RS485 Modbus-RTU.
Yes — recorded under "We will contact you immediately": Fill in more information so that we can get in touch with you faster.
Yes — recorded under "Communication": RS485 Modbus-RTU.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Fluorescence Dissolved Oxygen Sensor with RS485 Modbus-RTU Output

Md Series Analog Dissolved Oxygen Sensor

SUP-DO7013 Electrochemical dissolved oxygen sensor

SUP-DO7017 Optical dissolved oxygen sensor

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | OPD700 |
| Manufacturer | Daruifuno |
Oxygen Sensors
Fluorescence dissolved oxygen sensor with RS-485 and 4-20mA · Ref. : WQ-DO-4A
Price on request
Oxygen Sensors
Drinking Water Dissolved Oxygen Sensor Probe
Price on request
Oxygen Sensors
Wall-Mounted Oxygen Transmitter with RS485 Output
Price on request
Oxygen Sensors
Industrial dissolved oxygen sensor, 0-20 mg/L range · Ref. : DOG-209FA
Price on request