00382
RS-485 Modbus optical dissolved oxygen sensor

- Operating Temperature
- 0°C to 45°C (unfrozen)
- Signal Interface
- Modbus RS-485
- Cable
- 10m (standard),100m(optional)
- Ingress Protection
- IP68/NEMA6P
RS-485 Modbus optical dissolved oxygen sensor
Online optical dissolved oxygen sensor for monitoring dissolved oxygen in regulating pools, biochemical ponds, effluents and aquaculture, with Modbus RS-485 output.
Overview. The SUP-DO7017 is an optical dissolved oxygen sensor from manufacturer Supmea, designed for online measurement of dissolved oxygen in industrial processes. It is intended for continuous dissolved oxygen monitoring in regulating pools, biochemical ponds and effluents of sewage treatment plants.
Main characteristics. The sensor measures dissolved oxygen from 0 to 20 mg/L or 0 to 200% saturation, and temperature from 0 to 45 °C. Accuracy is ±3% or ±0.3 mg/L for dissolved oxygen and ±0.5 °C for temperature. Repeatability is ±0.3 and resolution is 0.01. The maximum pressure is 0.1 MPa. The body is made of 316L stainless steel.
Interfaces and connectivity. The output signal is Modbus RS-485, allowing connection to a PLC or a supervision system. The standard cable is 10 m long, and a 100 m version is available as an option.
Power and environment. The sensor is powered from 10 to 25 VDC. Its ingress protection rating is IP68 / NEMA 6P. The operating temperature is 0 °C to 45 °C, unfrozen, and the storage temperature is -15 °C to +60 °C.
Typical uses. The sensor suits dissolved oxygen monitoring in surface water, water treatment installations, aquaculture and industrial processes using water.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 00382, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accuracy | Dissolved oxygen: measured value ±3% or ±0.3mg/L; Temperature: ±0.5℃ |
| Cable | 10m (standard),100m(optional) |
| Ingress Protection | IP68/NEMA6P |
| Material | Stainless steel 316L |
| Maximum Pressure | 0.1 MPa |
| Measure range | Dissolved oxygen: (0~20) mg/L or 0~200% saturation; Temperature: (0~45)℃ |
| Model | SUP-DO7017 |
| Operating Temperature | 0°C to 45°C (unfrozen) |
| Power supply | (10-25) VDC |
| Repeatability | ±0.3 |
| Resolution | 0.01 |
| Signal Interface | Modbus RS-485 |
| Stocking temperature | -15°C to + 60°C |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for 00382. For a missing document or a specific revision, our experts send it to you.
Online optical dissolved oxygen sensor for monitoring dissolved oxygen in regulating pools, biochemical ponds, effluents and aquaculture, with Modbus RS-485 output.
| Parameter | Value |
|---|---|
| Accuracy | Dissolved oxygen: measured value ±3% or ±0.3mg/L; Temperature: ±0.5℃ |
| Cable | 10m (standard),100m(optional) |
| Ingress Protection | IP68/NEMA6P |
| Material | Stainless steel 316L |
| Maximum Pressure | 0.1 MPa |
| Measure range | Dissolved oxygen: (0~20) mg/L or 0~200% saturation; Temperature: (0~45)℃ |
| Model | SUP-DO7017 |
| Operating Temperature | 0°C to 45°C (unfrozen) |
| Power supply | (10-25) VDC |
| Repeatability | ±0.3 |
| Resolution | 0.01 |
| Signal Interface | Modbus RS-485 |
| Stocking temperature | -15°C to + 60°C |
Points to check before using 00382 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Power supply | (10-25) VDC |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of 00382 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Signal Interface": Modbus RS-485.
Yes — recorded under "Signal Interface": Modbus RS-485.
0°C to 45°C (unfrozen) (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
RS-485 Modbus optical dissolved oxygen sensor

SUP-DO7013 Electrochemical dissolved oxygen sensor

SUP-DO7018 Optical dissolved oxygen sensor

Advanced Drinking Water Dissolved Oxygen Sensor & Probe

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 00382 |
| Manufacturer | Supmea |
Oxygen Sensors
Fluorescence dissolved oxygen sensor with RS-485 and 4-20mA · Ref. : WQ-DO-4A
Price on request
Oxygen Sensors
Drinking Water Dissolved Oxygen Sensor Probe
Price on request
Oxygen Sensors
Wall-Mounted Oxygen Transmitter with RS485 Output
Price on request
Oxygen Sensors
Industrial dissolved oxygen sensor, 0-20 mg/L range · Ref. : DOG-209FA
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details