NBL-WQ-DO-4A – Fluorescence dissolved oxygen sensor with RS-485 and 4-20mA

Fluorescence dissolved oxygen sensor with RS-485 and 4-20mA

Oxygen Sensors

  • 0.2W @12V / 12~24V DC
  • ±2% of reading;±0.3℃
  • Power negative (GND)
  • RS485-A
Manufacturer part number
WQ-DO-4A
Manufacturer
Niubol
Accuracy
±2% of reading;±0.3℃
Black Wire
Power negative (GND)

Online fluorescence dissolved oxygen sensor with RS-485 Modbus-RTU digital output and optional 4-20mA output, for aquaculture and industrial wastewater monitoring.

Product overview

Niubol NBL-WQ-DO-4A, fluorescence dissolved oxygen sensor — This online sensor from Niubol measures dissolved oxygen by the fluorescence method, using physical quenching, with no electrolyte and no oxygen consumption. It covers a range of 0 to 20.00 mg/L or 0 to 200% saturation, with a resolution of 0.01 mg/L and a minimum detection limit of 0.08 mg/L.

Accuracy and compensation. Accuracy is ±2% of reading and ±0.3 °C. Automatic temperature compensation by Pt1000 and built-in salinity compensation correct measurement deviations caused by water quality. The response time T90 is less than 30 s.

Connectivity and outputs. The sensor provides an RS-485 output with Modbus-RTU protocol, using the RS485-A (blue wire) and RS485-B (white wire) lines, and an optional 4-20mA current output on the yellow wire, to be insulated and left floating if not used.

Power and environment. Power supply of 12 to 24 V DC (red wire positive, black wire GND), consumption of 0.2 W at 12 V. Protection rating IP68, POM and ABS/PC alloy housing, working conditions of 0 to 50 °C and up to 0.2 MPa. The fluorescent membrane head has a life of approximately one year under normal use.

Typical uses. Its Modbus-RTU protocol allows integration into a supervisory system or a PLC, for dissolved oxygen monitoring in aquaculture, industrial wastewater treatment and environmental monitoring.

See all specifications

Highlights

  • Accuracy: ±2% of reading;±0.3℃
  • Black Wire: Power negative (GND)
  • Blue Wire: RS485-A
  • Housing Material: POM, ABS/PC alloy
  • Measurement Principle: Fluorescence Method
  • Membrane Head Life: Approximately 1 year (under normal use)