SEN0564
MEMS Carbon Monoxide (CO) Gas Detection Sensor, Breakout Module

- Operating Temperature
- -10-50℃
- Detection range
- 5-5000ppm
- Operating Current
- <20 mA
- Dimension
- 13×13 x 2.5mm/0.0.51×0.51x0.1"
MEMS Carbon Monoxide (CO) Gas Detection Sensor, Breakout Module
Educational STEM Coding & Sensor Starter Packs
MEMS carbon monoxide gas sensor in a breakout format for CO leak alarms and portable CO detectors, with an analog voltage output.
Overview. The DFRobot SEN0564 is a MEMS carbon monoxide (CO) gas detection sensor in a 13 x 13 x 2.5 mm breakout format. It measures CO concentrations qualitatively and is suitable for carbon monoxide leak alarms and portable CO detectors.
Main characteristics. The detection range spans 5 to 5000 ppm. Power consumption is below 20 mA, with minimal heat generation, a short preheating time and fast response recovery. The sensitivity ratio R0 (in air) / Rs (in 150 ppm CO) is greater than or equal to 3.
Power and environment. The operating voltage is 3.3 to 5 V. The operating temperature ranges from -10 to 50 °C and the operating humidity from 15 to 90 %RH, non-condensing. The lifespan is at least 5 years in air.
Output signal and integration. The sensor delivers an analog voltage signal, allowing direct connection to an analog input of a microcontroller such as an Arduino UNO, following the wiring diagram provided by the manufacturer.
Typical uses. Carbon monoxide detection in petrochemical, metallurgy and mining applications, and environmental protection. The manufacturer specifies that this sensor is for qualitative measurement only; for quantitative measurement it recommends a factory-calibrated electrochemical CO sensor.
Precautions for use. Remove the protective film before use. Avoid volatile silicon compound vapours, high concentrations of corrosive gases, alkalis, water, condensation and freezing, and excessive vibration or impact. Preheat the module for at least 24 hours after prolonged non-use. The manufacturer advises against using this module in systems involving personal safety.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for SEN0564, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Detection range | 5-5000ppm |
| Dimension | 13×13 x 2.5mm/0.0.51×0.51x0.1" |
| Fermion | MEMS Carbon Monoxide CO Gas Detection Sensor (Breakout, 5-5000ppm) |
| Gas detected | CO |
| Lifespan | ≥5 years (in air) |
| Operating Current | <20 mA |
| Operating Humidity | 15-90%RH (non-condensing) |
| Operating Temperature | -10-50℃ |
| Operating Voltage | 3.3-5V |
| Output signal | Analog voltage |
| Sensitivity | R0(in air)/Rs(in 150ppm CO) ≥ 3 |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for SEN0564. For a missing document or a specific revision, our experts send it to you.
MEMS carbon monoxide gas sensor in a breakout format for CO leak alarms and portable CO detectors, with an analog voltage output.
| Parameter | Value |
|---|---|
| Detection range | 5-5000ppm |
| Dimension | 13×13 x 2.5mm/0.0.51×0.51x0.1" |
| Fermion | MEMS Carbon Monoxide CO Gas Detection Sensor (Breakout, 5-5000ppm) |
| Gas detected | CO |
| Lifespan | ≥5 years (in air) |
| Operating Current | <20 mA |
| Operating Humidity | 15-90%RH (non-condensing) |
| Operating Temperature | -10-50℃ |
| Operating Voltage | 3.3-5V |
| Output signal | Analog voltage |
| Sensitivity | R0(in air)/Rs(in 150ppm CO) ≥ 3 |
Points to check before using SEN0564 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Operating Current | <20 mA |
| Operating Voltage | 3.3-5V |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of SEN0564 can answer. A question is not asked when nothing is recorded to answer it.
-10-50℃ (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
MEMS Carbon Monoxide (CO) Gas Detection Sensor, Breakout Module

Fermion: MEMS Odor Smell Gas Detection Sensor (Breakout, 0.5-50ppm)

Fermion: MEMS Hydrogen H2 Gas Detection Sensor (Breakout, 0.1-1000ppm)

5pcs 1.5V-6V Type Miniature DC Motors

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | SEN0564 |
| Manufacturer | DFRobot |
Educational STEM Coding & Sensor Starter Packs
5 V Power Booster and Charger Module for Single-Cell Lithium Battery · Ref. : DFR0446
Price on request
Educational STEM Coding & Sensor Starter Packs
30 kg·cm magnetic encoder bus servo 360° · Ref. : 21100250
Price on request
Educational STEM Coding & Sensor Starter Packs
ROS2 Omnidirectional Mecanum Wheel Mobile Robot · Ref. : 3000200901
Price on request
Educational STEM Coding & Sensor Starter Packs
ESP32 robot chassis expansion shield
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details