SEN0572
MEMS Hydrogen H2 Gas Sensor, Analog Voltage Output

- Operating Temperature
- -10-50℃
- Detection range
- 0.1-1000ppm
- Operating Current
- <20mA
- Dimension
- 13×13 x 2.5mm/0.0.51×0.51x0.1"
MEMS Hydrogen H2 Gas Sensor, Analog Voltage Output
Educational STEM Coding & Sensor Starter Packs
Compact MEMS sensor for qualitative detection of hydrogen (H2) with analog voltage output, intended for hydrogen leakage alarms and industrial safety applications.
Overview. The SEN0572 from DFRobot is a MEMS hydrogen (H2) gas sensor supplied as a breakout module. It detects hydrogen concentration qualitatively and suits hydrogen leakage alarms. Its advanced MEMS technology gives it compact dimensions of 13 × 13 × 2.5 mm.
Main characteristics. Detection range of 0.1 to 1000 ppm. Sensitivity R0 (in air) / Rs (in 200 ppm H2) greater than or equal to 5. Fast response and recovery, with short preheating time and minimal heat generation. Lifespan of 5 years or more in air.
Output and power. Analog voltage output. Operating voltage of 3.3 to 5 V and operating current below 20 mA, for low power consumption.
Environmental conditions. Operating temperature of -10 to 50 °C and operating humidity of 15 to 90 %RH, non-condensing. The manufacturer advises avoiding contact with water, condensation and freezing, as well as volatile silicon compound vapours, high concentrations of corrosive gases, and contamination by alkalis and halogens.
Typical uses. Ambient air quality monitoring, hydrogen emission monitoring in fuel cell vehicles, and detection of hydrogen or other flammable gas leaks in industrial processes and workplaces. The manufacturer specifies that this module must not be used in systems where personal safety is at stake.
Integration. The module connects to an Arduino UNO-type board following the manufacturer's wiring diagram. For quantitative measurements, the manufacturer refers to its factory-calibrated Gravity electrochemical gas sensor series.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for SEN0572, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Detection range | 0.1-1000ppm |
| Dimension | 13×13 x 2.5mm/0.0.51×0.51x0.1" |
| Fermion | MEMS Hydrogen H2 Gas Detection Sensor (Breakout, 0.1-1000ppm) |
| Gas detected | Hydrogen (H2) |
| Lifespan | ≥5 years (in air) |
| Operating Current | <20mA |
| Operating Humidity | 15-90%RH (non-condensing) |
| Operating Temperature | -10-50℃ |
| Operating Voltage | 3.3-5V |
| Output signal | Analog voltage |
| Sensitivity | R0(in air)/Rs(in 200ppm H2) ≥ 5 |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for SEN0572. For a missing document or a specific revision, our experts send it to you.
Compact MEMS sensor for qualitative detection of hydrogen (H2) with analog voltage output, intended for hydrogen leakage alarms and industrial safety applications.
| Parameter | Value |
|---|---|
| Detection range | 0.1-1000ppm |
| Dimension | 13×13 x 2.5mm/0.0.51×0.51x0.1" |
| Fermion | MEMS Hydrogen H2 Gas Detection Sensor (Breakout, 0.1-1000ppm) |
| Gas detected | Hydrogen (H2) |
| Lifespan | ≥5 years (in air) |
| Operating Current | <20mA |
| Operating Humidity | 15-90%RH (non-condensing) |
| Operating Temperature | -10-50℃ |
| Operating Voltage | 3.3-5V |
| Output signal | Analog voltage |
| Sensitivity | R0(in air)/Rs(in 200ppm H2) ≥ 5 |
Points to check before using SEN0572 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Operating Current | <20mA |
| Operating Voltage | 3.3-5V |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of SEN0572 can answer. A question is not asked when nothing is recorded to answer it.
-10-50℃ (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
MEMS Hydrogen H2 Gas Sensor, Analog Voltage Output

Fermion: MEMS Odor Smell Gas Detection Sensor (Breakout, 0.5-50ppm)

Fermion: MEMS Carbon Monoxide CO Gas Detection Sensor (Breakout, 5-5000ppm)

5pcs 1.5V-6V Type Miniature DC Motors

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | SEN0572 |
| Manufacturer | DFRobot |
Educational STEM Coding & Sensor Starter Packs
5 V Power Booster and Charger Module for Single-Cell Lithium Battery · Ref. : DFR0446
Price on request
Educational STEM Coding & Sensor Starter Packs
30 kg·cm magnetic encoder bus servo 360° · Ref. : 21100250
Price on request
Educational STEM Coding & Sensor Starter Packs
ROS2 Omnidirectional Mecanum Wheel Mobile Robot · Ref. : 3000200901
Price on request
Educational STEM Coding & Sensor Starter Packs
ESP32 robot chassis expansion shield
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details