SFA40 – Electrochemical HCHO formaldehyde sensor 0-2000 ppb

Electrochemical HCHO formaldehyde sensor 0-2000 ppb

DFRobot Gravity Sensor & Actuator System

  • 0~50℃
  • 0~2000ppb
  • 3.3–5V
  • <2min
Manufacturer part number
SEN0661
Manufacturer
DFRobot
Operating Temperature
0~50℃
Supply voltage
3.3–5V

Electrochemical formaldehyde (HCHO) measurement module for indoor air quality monitoring, 0-2000 ppb range, with integrated SHT4x temperature and humidity sensing and a Gravity I2C interface.

Product overview

Sensor DFRobot SEN0661. The Gravity: SFA40 Formaldehyde (HCHO) Sensor is an electrochemical formaldehyde detection module based on the Sensirion SFA40 chip, designed to measure HCHO concentrations from 0 to 2000 ppb with an accuracy of ±20 ppb.

Main characteristics. The module has a detection threshold of 20 ppb, an ethanol cross-sensitivity below 0.3% (15 ppb output in 5 ppm ethanol) and a long-term drift below 5 ppb or 5% of the measured value per year, whichever is larger. The response time is under 2 minutes, the startup time after power-on is 10 minutes and the stated lifetime exceeds 6 years.

Interfaces and connectivity. The sensor uses a Gravity I2C interface compatible with Arduino platforms and other development boards. It integrates an SHT4x temperature and humidity sensor allowing automatic environmental compensation of the measurements.

Power and environment. The supply voltage is 3.3 to 5 V. The operating current is 80 μA on average at 2 Hz and 2 mA peak. The module operates between 0 and 50 °C and between 10 and 90% relative humidity, with dimensions of 32 × 22 mm.

Typical uses. This module suits indoor air quality monitoring, HVAC monitoring systems, smart home projects and experimental air quality instrumentation.

Integration. Thanks to its I2C interface and Arduino compatibility, the sensor connects directly to development boards and data acquisition systems.

See all specifications

Highlights

  • Supply voltage: 3.3–5V
  • Response time: <2min
  • Cross-sensitivity to ethanol: 0.3%(15ppb output in 5ppm ethanol)
  • Formaldehyde measurement range: 0~2000ppb
  • Gravity: SFA40 Formaldehyde (HCHO) Sensor (0-2000ppb, ±20ppb Accuracy)
  • Lifttime: > 6years

Good to know before integrating

  • Power: plan for a supply compatible with 3.3–5V.
  • Thermal: rated operating range 0~50℃ — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote