LoRaWAN handheld food temperature probe with PT100 sensor, designed for remote monitoring of food temperature and food safety traceability.
Operating Temperature-40 ~ 85°C
Operating Range-50 °C to 260 °C
Supply voltageBuilt-in Battery, 2.5v ~ 3.0v
Max boost current2A, 1 second
Max continuously current130mA
Frequency Range, Band 1 (HF)862 ~ 1020 Mhz
Product overview
Overview. The Dragino LPT01 is a LoRaWAN handheld food thermometer, a food temperature probe for remote monitoring of food temperature. It automatically records temperature data and uploads it to an IoT platform, helping meet food safety regulations while reducing manual documentation errors.
Main characteristics. The probe uses an external class A PT100 temperature sensor with accuracy ±(0.15 + 0.002 * |t|) °C, a resolution of 0.01 °C and an operating range of -50 °C to 260 °C. The probe is 13.5 cm long with a 4 mm diameter, for a total device length of 28 cm. An LCD display is included.
Interfaces and connectivity. The device supports the LoRaWAN v1.0.3 Class A protocol, with a frequency range of 862 to 1020 MHz and RX sensitivity down to -139 dBm. Maximum constant RF output is +22 dBm. Uplinks can be sent periodically or on alarm event.
Power and environment. It runs on a non-rechargeable CR123A 1500mAh battery, supply voltage 2.5 to 3.0 V, with self-discharge below 1% per year at 25 °C. Consumption is 5 µA in sleep mode at 3.3 V and 125 mA in LoRa transmit mode at 20 dBm. Operating temperature ranges from -40 to 85 °C.
Typical uses. Cold chain monitoring, food management, logistics and supply chain management, industrial monitoring and control.
LoRaWAN handheld food temperature probe with PT100 sensor, designed for remote monitoring of food temperature and food safety traceability.
Operating Temperature-40 ~ 85°C
Operating Range-50 °C to 260 °C
Supply voltageBuilt-in Battery, 2.5v ~ 3.0v
Max boost current2A, 1 second
Max continuously current130mA
2. Datasheet extract (recorded values)
Parameter
Value
Supply voltage
Built-in Battery, 2.5v ~ 3.0v
Capacity
1500mAh
Frequency Range, Band 1 (HF)
862 ~ 1020 Mhz
LoRa Transmit Mode
125mA @ 20dBm, 82mA @ 14dBm
LPT01 total length
28cm
Max boost current
2A, 1 second
Max continuously current
130mA
Operating Range
-50 °C to 260 °C
Operating Temperature
-40 ~ 85°C
Probe diameter
4mm
Probe length
13.5cm
Resolution
0.01 °C
Self Discharge
<1% / Year @ 25°C
Sleep mode
5uA @ 3.3v
Integration
Points to check before using LPT01 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Powerplan for a supply compatible with Built-in Battery, 2.5v ~ 3.0v.
2Thermalrated operating range -40 ~ 85°C — check it against the installation environment.
Power and communication
Supply voltage
Built-in Battery, 2.5v ~ 3.0v
Max boost current
2A, 1 second
Max continuously current
130mA
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Power : plan for a supply compatible with Built-in Battery, 2.5v ~ 3.0v.
Thermal : rated operating range -40 ~ 85°C — check it against the installation environment.
Applications and use cases
Architectures in which LPT01 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for LPT01 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productDragino
LPT01
LoRaWAN handheld food thermometer with PT100 probe
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
SenseCAP SOLO CO2 5000 (A2) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12, with Waterproof Aviation Connector
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details