LoRaWAN water leak detection sensor placed on the floor, which signals any water bridging its three metal posts, for monitoring buildings and industrial sites.
Operating Temperature-40℃~+85℃
BatteryCR123A 1500mAh Battery
Battery Life2 ~ 10 years
Ingress ProtectionIP65
Uplink Packets16,000 ~ 70,000
Product overview
Overview. The Dragino LWL04 is a LoRaWAN water leak sensor. When water sits between the three metal posts at its base, it reports the leak event to the IoT server over the LoRaWAN network. It only needs to be placed on the ground, and its posts can be height-adjusted.
Main characteristics. The sensor operates in LoRaWAN Class A v1.0.3, supports wireless OTA firmware updates and configuration changes by downlink. It sends periodic daily data as well as data for each water leak event, and counts the number of leaks and the duration of the last one. Each device ships with a unique set of keys for LoRaWAN registration.
Interfaces and connectivity. Compatible with the CN470, EU433, KR920, US915, EU868, AS923, AU915, IN865 and RU864 frequency bands, the LWL04 connects automatically after power-on once its keys are registered on the LoRaWAN server.
Power and environment. Powered by a non-rechargeable CR123A 1500mAh battery, it provides 16,000 to 70,000 uplink packets, giving a battery life of 2 to 10 years. The housing, fitted with a sealing ring, achieves IP65 and operates from -40℃ to +85℃, although extreme temperatures can reduce battery discharge life. A magnet placed at the bottom of the housing activates it, and the battery is replaced by opening the enclosure.
Typical uses. Leak monitoring in smart factories, smart buildings and home automation.
LoRaWAN water leak detection sensor placed on the floor, which signals any water bridging its three metal posts, for monitoring buildings and industrial sites.
Points to check before using LWL04 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -40℃~+85℃ — check it against the installation environment.
Power and communication
Battery
CR123A 1500mAh Battery
Battery Life
2 ~ 10 years
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -40℃~+85℃ — check it against the installation environment.
Applications and use cases
Architectures in which LWL04 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for LWL04 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
SenseCAP SOLO CO2 5000 (A2) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12, with Waterproof Aviation Connector
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details