Dragino SE02-LB LoRaWAN sensor with two 2.5 m probes measuring soil moisture, temperature and electrical conductivity for connected agriculture.
Operating Temperature-40 ~ 85°C
Range0-100.00 V/V %
Supply voltageBuilt-in Battery, 2.5v ~ 3.6v
Max boost current2A, 1 second
Max continuously current130mA
Frequency Range, Band 1 (HF)862 ~ 1020 Mhz
Product overview
Overview. The Dragino SE02-LB is a LoRaWAN soil moisture and electrical conductivity sensor designed for connected agriculture. It measures soil moisture, soil temperature and soil conductivity, then transmits the values wirelessly to a LoRaWAN server. It is designed for saline-alkali soil and loamy soil.
Measurement characteristics. Soil moisture ranges from 0 to 100.00 V/V % with a resolution of 0.01 V/V % and an accuracy of ±3% (0-53%) V/V %, ±5% (>53%) V/V %, using the FDR method with temperature and EC compensation. Conductivity covers 0 to 20000 uS/cm (25℃), with a resolution of 1 uS/cm and an accuracy of 2%FS. Soil temperature ranges from -40.00℃ to 85.00℃.
Connectivity. The sensor operates in the CN470, EU433, KR920, US915, EU868, AS923, AU915 and IN865 bands, over a frequency range of 862 to 1020 MHz, with a maximum constant RF output of +22 dBm and receive sensitivity down to -139 dBm. It complies with LoRaWAN 1.0.3 Class A and supports Bluetooth v5.1 for configuration as well as wireless OTA firmware update.
Power and environment. It is powered by an 8500mAh non-rechargeable Li/SOCl2 battery, with a supply voltage of 2.5 V to 3.6 V. Consumption is 5 µA in sleep mode at 3.3 V, 125 mA at 20 dBm and 82 mA at 14 dBm in transmit mode. The enclosure is IP66 waterproof and the operating temperature range is -40 to 85 °C.
Typical uses. The SE02-LB is suited to smart agriculture for monitoring irrigation and soil salinity.
Dragino SE02-LB LoRaWAN sensor with two 2.5 m probes measuring soil moisture, temperature and electrical conductivity for connected agriculture.
Operating Temperature-40 ~ 85°C
Range0-100.00 V/V %
Supply voltageBuilt-in Battery, 2.5v ~ 3.6v
Max boost current2A, 1 second
Max continuously current130mA
2. Datasheet extract (recorded values)
Parameter
Value
Supply voltage
Built-in Battery, 2.5v ~ 3.6v
Accuracy
±3% (0-53%)V/V %, ±5% (>53%) V/V %
Bands
CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865
Capacity
8500mAh
External 2× sensor probes, probe length
2.5m
Frequency Range, Band 1 (HF)
862 ~ 1020 Mhz
LoRa Transmit Mode
125mA @ 20dBm, 82mA @ 14dBm
Max boost current
2A, 1 second
Max continuously current
130mA
Measure Method
FDR, with temperature &EC compensate
Operating Temperature
-40 ~ 85°C
Range
0-100.00 V/V %
Resolution
0.01 V/V %
Self Discharge
<1% / Year @ 25°C
Sleep mode
5uA @ 3.3v
Integration
Points to check before using SE02-LB in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Powerplan for a supply compatible with Built-in Battery, 2.5v ~ 3.6v.
2Thermalrated operating range -40 ~ 85°C — check it against the installation environment.
Power and communication
Supply voltage
Built-in Battery, 2.5v ~ 3.6v
Max boost current
2A, 1 second
Max continuously current
130mA
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Power : plan for a supply compatible with Built-in Battery, 2.5v ~ 3.6v.
Thermal : rated operating range -40 ~ 85°C — check it against the installation environment.
Applications and use cases
Architectures in which SE02-LB can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for SE02-LB and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
SenseCAP SOLO CO2 5000 (A2) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12, with Waterproof Aviation Connector
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details