Dragino SPH01-LB/LS LoRaWAN sensor measuring soil pH and temperature for smart agriculture, with an IP68 probe that can stay buried long term.
Operating Temperature-40 ~ 85°C
Range3 ~ 10 pH
Temperature Compensation Range0 ~ 50℃
Supply voltageBuilt-in Battery, 2.5v ~ 3.6v
Max boost current2A, 1 second
Max continuously current130mA
Product overview
Overview. The Dragino SPH01-LB/LS is a LoRaWAN soil pH sensor designed for agricultural IoT. It measures soil pH and soil temperature and sends the data to a platform to analyse the acid or alkali level of the soil. The probe is IP68 and can be buried in soil for long-term use.
Main characteristics. The pH range is 3 to 10 with a resolution of 0.01 pH and an accuracy of ±2 % between 0 and 50 ℃, with temperature compensation from 0 to 50 ℃. Soil temperature is measured from -40 ℃ to 85 ℃ with a resolution of 0.1 ℃. The probe is 3.5 metres long.
Interfaces and connectivity. The sensor operates as LoRaWAN 1.0.3 Class A on the CN470, EU433, KR920, US915, EU868, AS923, AU915 and IN865 bands, with a frequency range of 862 to 1020 MHz and receive sensitivity down to -139 dBm. It supports Bluetooth v5.1 for configuration, wireless OTA firmware updates and AT commands.
Power and environment. It is powered by an 8500 mAh Li/SOCl2 battery (SPH01-LB) or by a solar panel and 3000 mAh Li-ion battery (SPH01-LS). Consumption is 5 µA in sleep mode at 3.3 V and 125 mA in transmit mode at 20 dBm. It operates from -40 to 85 ℃, with an IP66 enclosure.
Typical uses. Monitoring of soil pH and temperature in smart agriculture.
Dragino SPH01-LB/LS LoRaWAN sensor measuring soil pH and temperature for smart agriculture, with an IP68 probe that can stay buried long term.
Operating Temperature-40 ~ 85°C
Range3 ~ 10 pH
Temperature Compensation Range0 ~ 50℃
Supply voltageBuilt-in Battery, 2.5v ~ 3.6v
Max boost current2A, 1 second
2. Datasheet extract (recorded values)
Parameter
Value
Supply voltage
Built-in Battery, 2.5v ~ 3.6v
Accuracy
±2% under (0~50 ℃, Accuracy will poor under 0 due to frozen)
Bands
CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865
Capacity
8500mAh
Frequency Range, Band 1 (HF)
862 ~ 1020 Mhz
Length
3.5 meters
LoRa Transmit Mode
125mA @ 20dBm, 82mA @ 14dBm
Max boost current
2A, 1 second
Max continuously current
130mA
Operating Temperature
-40 ~ 85°C
Range
3 ~ 10 pH
Resolution
0.01 pH
Self Discharge
<1% / Year @ 25°C
Sleep mode
5uA @ 3.3v
Temperature Compensation Range
0 ~ 50℃
Integration
Points to check before using SPH01-LB/LS in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Powerplan for a supply compatible with Built-in Battery, 2.5v ~ 3.6v.
2Thermalrated operating range -40 ~ 85°C — check it against the installation environment.
Power and communication
Supply voltage
Built-in Battery, 2.5v ~ 3.6v
Max boost current
2A, 1 second
Max continuously current
130mA
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Power : plan for a supply compatible with Built-in Battery, 2.5v ~ 3.6v.
Thermal : rated operating range -40 ~ 85°C — check it against the installation environment.
Applications and use cases
Architectures in which SPH01-LB/LS can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for SPH01-LB/LS and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
SenseCAP SOLO CO2 5000 (A2) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12, with Waterproof Aviation Connector
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details