Outdoor LoRaWAN tilting sensor Dragino TS01-LB/LS measuring pitch and roll of trees, buildings or large equipment, with built-in battery.
Operating Temperature-40 ~ 85°C
Angle Range-180°~180°
Supply voltageBuilt-in Battery, 2.5v ~ 3.6v
Max boost current2A, 1 second
Max continuously current130mA
Accuracy0.3°
Product overview
Dragino TS01-LB/LS. LoRaWAN tilting sensor designed to measure the angle of trees, buildings or large-scale equipment, sending data over a LoRaWAN network to an IoT platform.
Angle measurement. The sensor measures pitch and roll over an angle range of -180° to 180°, with an accuracy of 0.3° and an angular resolution of 0.1° (0.05° when the object under test is fixed). It supports angle alarm and datalog features.
Connectivity. LoRaWAN 1.0.3 Class A, with bands CN470, EU433, KR920, US915, EU868, AS923, AU915 and IN865. Frequency range covers Band 1 (HF) from 862 to 1020 MHz and Band 2 (LF) from 410 to 528 MHz. Remote configuration via Bluetooth v5.1 and LoRaWAN, and wireless OTA firmware update.
Power and environment. Powered by a built-in 8500 mAh Li/SOCl2 battery, 2.5 V to 3.6 V, with self-discharge below 1% per year at 25 °C. Consumption of 5 µA in sleep mode at 3.3 V, 125 mA in transmit mode at 20 dBm and 82 mA at 14 dBm. Operating temperature from -40 to 85 °C.
Typical uses. Monitoring the tilt of trees, buildings or large equipment outdoors, with periodic transmission of measurements and battery level monitoring.
Integration. Each sensor is pre-loaded with a set of unique keys for LoRaWAN registration on a local server and connects automatically after power-on. Parameters can be configured via downlink.
Outdoor LoRaWAN tilting sensor Dragino TS01-LB/LS measuring pitch and roll of trees, buildings or large equipment, with built-in battery.
Operating Temperature-40 ~ 85°C
Angle Range-180°~180°
Supply voltageBuilt-in Battery, 2.5v ~ 3.6v
Max boost current2A, 1 second
Max continuously current130mA
2. Datasheet extract (recorded values)
Parameter
Value
Supply voltage
Built-in Battery, 2.5v ~ 3.6v
Accuracy
0.3°
Angle Range
-180°~180°
Bands
CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865
Capacity
8500mAh
Frequency Range, Band 1 (HF)
862 ~ 1020 Mhz, Band 2 (LF): 410 ~ 528 Mhz
LoRa Transmit Mode
125mA @ 20dBm, 82mA @ 14dBm
Max boost current
2A, 1 second
Max continuously current
130mA
Operating Temperature
-40 ~ 85°C
Self Discharge
<1% / Year @ 25°C
Sleep mode
5uA @ 3.3v
Integration
Points to check before using TS01-LB/LS in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Powerplan for a supply compatible with Built-in Battery, 2.5v ~ 3.6v.
2Thermalrated operating range -40 ~ 85°C — check it against the installation environment.
Power and communication
Supply voltage
Built-in Battery, 2.5v ~ 3.6v
Max boost current
2A, 1 second
Max continuously current
130mA
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Power : plan for a supply compatible with Built-in Battery, 2.5v ~ 3.6v.
Thermal : rated operating range -40 ~ 85°C — check it against the installation environment.
Applications and use cases
Architectures in which TS01-LB/LS can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for TS01-LB/LS and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
SenseCAP SOLO CO2 5000 (A2) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12, with Waterproof Aviation Connector
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.