Compact LoRaWAN weather station kit combining a transmitter, a 3-in-1 temperature, humidity and pressure sensor, an illuminance sensor and a rain gauge, designed to measure atmospheric conditions.
Operating Range-40 °C ~ 85 °C
Rain intensity range0.01~4mm/min
Range-40 to + 80°C
Accuracy±0.2 @ 0-90 °C
Cable Length50cm
Cable speci cation2 meters 2 wire system (pulse signal)
Product overview
Overview. The Dragino WSC2-Compact-LS is a third-generation LoRaWAN weather station kit designed to measure atmospheric conditions and provide information for weather forecasts and the study of weather and climate. It includes a LoRaWAN transmitter, a 3-in-1 temperature, humidity and air pressure sensor, an illuminance sensor and a rain gauge.
Main characteristics. The DR-THP-6P 3-in-1 sensor measures temperature over -40 to +80 °C with an accuracy of ±0.2 °C between 0 and 90 °C and a resolution of 0.1 °C, humidity over 0 to 99.9 % RH with an accuracy of ±2 % RH between 0 and 100 % RH, and air pressure over 300 to 1100 hPa. The DR-IL-6P illuminance sensor, based on the BH1750, offers a resolution of 1 lx over a range of 0 to 65535 lx. The DR-RG-6P rain gauge, with a rain-bearing diameter of 200 mm, measures over a default range of 0 to 100 mm/day with a resolution of 0.1 mm and a rain intensity range of 0.01 to 4 mm/min.
Interfaces and connectivity. The transmitter operates in LoRaWAN 1.0.3 Class A and supports the CN470, EU433, KR920, US915, EU868, AS923, AU915 and IN865 bands. It uses an I2C interface to communicate with the weather station and has a pulse count input for a tipping bucket rain gauge. Parameters can be configured remotely over LoRaWAN or Bluetooth v5.1, through AT commands or downlink, and firmware can be updated wirelessly over the air (OTA).
Power and environment. The transmitter has a 3000 mAh rechargeable Li-ion battery and an IP66 waterproof enclosure. Its power consumption is ultra-low, and it requires no extra power supply or MQTT. The illuminance sensor supports an operating range of -40 °C to 85 °C.
Typical uses. This kit suits remote weather measurement, climate observation station networks and installations requiring long-range, low-power transmission.
Installation. The illuminance sensor cable is 50 cm long and the rain gauge cable is 2 metres long, a 2-wire system with pulse signal.
Compact LoRaWAN weather station kit combining a transmitter, a 3-in-1 temperature, humidity and pressure sensor, an illuminance sensor and a rain gauge, designed to measure atmospheric conditions.
Operating Range-40 °C ~ 85 °C
Rain intensity range0.01~4mm/min
Range-40 to + 80°C
Accuracy±0.2 @ 0-90 °C
Cable Length50cm
2. Datasheet extract (recorded values)
Parameter
Value
Accuracy
±0.2 @ 0-90 °C
Bands
CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865
Cable Length
50cm
Cable speci cation
2 meters 2 wire system (pulse signal)
Long Term Shift
<0.03 °C/yr
Operating Range
-40 °C ~ 85 °C
Output signal
pulse signal
Rain-bearing diameter
200mm; sharp angle of blade: 40° ~ 45°
Rain intensity range
0.01~4mm/min
Range
-40 to + 80°C
Resolution
0.1°C
Applications and use cases
Architectures in which WSC2-COMPACT-LS can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for WSC2-COMPACT-LS and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
SenseCAP SOLO CO2 5000 (A2) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12, with Waterproof Aviation Connector
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details