The Dragino WSS-23 is an RS485 air quality sensor that measures CO2, PM2.5 and PM10 at the same time, intended notably for weather stations.
CO2 Range0~5000ppm, accuracy: ±3%F•S(25℃)
PM2.5/PM10 Range0~1000μg/m3, accuracy ±3%F•S(25℃)
InterfaceRS485
CO2 resolution1ppm
Input powerDC 7 ~ 24v
PM2.5/PM10 resolution1μg/m3
Product overview
Overview. The Dragino WSS-23 is an RS485 air quality sensor that measures CO2, PM2.5 and PM10 at the same time. It uses a weather proof shield that protects the sensors against UV and radiation.
Main characteristics. CO2 is measured by NDIR technology with internal temperature compensation, over a range of 0 to 5000 ppm, with an accuracy of ±3%F•S at 25 °C and a resolution of 1 ppm. PM2.5 and PM10 are measured by laser beam scattering, over a range of 0 to 1000 μg/m3, with an accuracy of ±3%F•S at 25 °C and a resolution of 1 μg/m3. The preheat time is 3 minutes.
Interface and power. The sensor communicates over an RS485 interface and is powered from a DC 7 to 24 V supply. Its power consumption is 50 mA at 12 V.
Operating conditions. The working temperature is 0 to 50 °C for CO2 and -30 to 50 °C for PM2.5 and PM10. The working humidity is 0 to 95 %RH for CO2 and 15 to 80 %RH without dewing for PM2.5 and PM10. Device dimensions are 24 x 24 x 15 cm, for a weight of 1248 g.
Typical uses. The WSS-23 is suited to weather station applications, where its RS485 output allows connection to a data acquisition system.
The Dragino WSS-23 is an RS485 air quality sensor that measures CO2, PM2.5 and PM10 at the same time, intended notably for weather stations.
CO2 Range0~5000ppm, accuracy: ±3%F•S(25℃)
PM2.5/PM10 Range0~1000μg/m3, accuracy ±3%F•S(25℃)
InterfaceRS485
CO2 resolution1ppm
Input powerDC 7 ~ 24v
2. Datasheet extract (recorded values)
Parameter
Value
CO2 Range
0~5000ppm, accuracy: ±3%F•S(25℃)
CO2 resolution
1ppm
Input power
DC 7 ~ 24v
Interface
RS485
PM2.5/PM10 Range
0~1000μg/m3, accuracy ±3%F•S(25℃)
PM2.5/PM10 resolution
1μg/m3
Preheat time
3min
Working humidity
PM2.5/PM10: 15~80%RH (no dewing); CO2: 0~95%RH
Working temperature
CO2: 0℃~50℃; PM2.5/PM10: -30 ~ 50℃
Applications and use cases
Architectures in which WSS-23 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for WSS-23 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productDragino
WSS-23
RS485 CO2, PM2.5 and PM10 sensor for weather station
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
SenseCAP SOLO CO2 5000 (A2) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12, with Waterproof Aviation Connector
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details