The Dragino WSS-26 is a total solar radiation sensor with RS485 output, measuring 0 to 2000 W/m2 over the 0.3 to 3 μm spectral range. It is used in particular in weather stations.
Measure strength range0~2000W/m2
InterfaceRS485
Power consumption4mA @ 12v
Accuracy±3%
Cosine response≤7%(@ Sun angle 10°)
Detect spectrum0.3~3μm(300~3000nm)
Product overview
Overview. The Dragino WSS-26 is a total solar radiation sensor that measures total solar radiation over the 0.3 to 3 μm spectral range (300 to 3000 nm). With the sensing face pointing down, it measures reflected radiation, and the shading ring can be used to measure scattered radiation.
Main characteristics. The sensor uses a high-precision photosensitive element with good stability, protected by a precision-machined PTFE radiation cover. Measurement range 0 to 2000 W/m2, resolution 0.1 W/m2 and accuracy ±3%. Yearly stability within ±2%, temperature effect ±2% between -10 °C and 40 °C, and cosine response of 7% or less at a sun angle of 10°.
Interfaces and power. RS485 output and DC 5 to 24 V power supply. Power consumption 4 mA at 12 V.
Environment. Working temperature -40 °C to 70 °C, working humidity 10 to 90 %RH.
Typical uses. The sensor is intended for weather stations. Its RS485 output allows connection to a data acquisition system or a compatible controller.
The Dragino WSS-26 is a total solar radiation sensor with RS485 output, measuring 0 to 2000 W/m2 over the 0.3 to 3 μm spectral range. It is used in particular in weather stations.
Measure strength range0~2000W/m2
InterfaceRS485
Power consumption4mA @ 12v
Accuracy±3%
Cosine response≤7%(@ Sun angle 10°)
2. Datasheet extract (recorded values)
Parameter
Value
Accuracy
±3%
Cosine response
≤7%(@ Sun angle 10°)
Detect spectrum
0.3~3μm(300~3000nm)
Input power
DC 5 ~ 24v
Interface
RS485
Measure strength range
0~2000W/m2
Power consumption
4mA @ 12v
Resolution
0.1W/m2
Temperature effect
±2%(-10℃~40℃)
Working humidity
10~90%RH
Working temperature
-40℃~70℃
Yearly Stability
≤±2%
Applications and use cases
Architectures in which WSS-26 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for WSS-26 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
SenseCAP SOLO CO2 5000 (A2) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12, with Waterproof Aviation Connector
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details