Smart X96-5G – Three-phase power analyser with 4 digital inputs, 2 outputs and RS485

Three-phase power analyser with 4 digital inputs, 2 outputs and RS485

Three-Phase Energy Meters

  • -25 to 55°C
  • 9999A
  • 0.25A
  • 5A
Manufacturer part number
2DO
Manufacturer
Eastron
Operating Temperature
-25 to 55°C
Input-Current — Max Current
9999A

Three-phase multi-function panel meter for electricity distribution, measuring voltage, current, power, energy and harmonics up to the 63rd, in a 96x96 mm panel-mounted case.

Product overview

Eastron Smart X96-5G is a 4DI 2DO three-phase panel-mounted multi-function panel meter for electricity distribution, designed as a three-phase energy meter with 4 digital inputs and 2 digital outputs.

Measurement. RMS measurement including harmonics on three-phase AC systems (3P4W, 3P+N and 3P3W), with voltage, current, frequency, active, reactive and apparent power, power factor, active and reactive energy and THD up to the 63rd harmonic. Accuracy Class 0.5S for active energy to IEC 62053-22 and Class 1.0 to IEC 62053-21.

Electrical characteristics. Rated current 5 A, minimum current 0.25 A and maximum current 9999 A. Measured voltage from 50 V to 600 V in 3P4W and from 50 V to 480 V in 3P3W. Auxiliary power supply 230 V L-N AC or 120 V to 380 V DC.

Communication. RS485 port with Modbus RTU protocol, 2-wire half duplex, baud rates from 2400 to 38400 bps, parity none, even or odd, 1 or 2 stop bits, addresses from 1 to 247. These settings allow remote monitoring and configuration.

Inputs and outputs. 4 digital inputs and 2 digital outputs for counting external signal pulses and controlling external devices.

Installation and environment. 96x96 mm case, 92 mm depth, weight 420 g, vertical panel cut-out, shrouded screw-clamp terminals. IP51 degree of protection on the front display, self-extinguishing UL 94 V-0 case material. Operating temperature -25 to 55 °C, storage temperature -40 to 70 °C, humidity below 95 % RH non-condensing, altitude up to 2000 m.

Typical uses. Monitoring and energy metering in three-phase electricity distribution installations, with data reporting to a PLC or supervisory system via Modbus RTU.

See all specifications

Highlights

  • Altitude: 2000m
  • Communication Address: 1 to 247
  • Communication — Baud rate: 2400,4800, 9600, 19200, 38400 bps
  • Communication — Pariy: None (default), Even, Odd
  • Communication — RS485 port: Modbus RTU (RS485)
  • Communication — Stop Bit: 1 or 2

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -25 to 55°C — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote