The Reallin E3016-SA three-phase four-wire meter measures active, reactive and apparent energy in CT and CT-VT configuration, with DLMS/COSEM communication.
Operating Temperature-25~75℃
Voltage Range80%Un~115%Un
Current Circuit Power Consumption<1VA
Maximum current Imax6A or 10A
Minimum Current (Imin)0.01A
Reference current Ib1A, 1.5A
Product overview
Reallin E3016-SA energy meter. The Reallin E3016-SA is a three-phase four-wire energy meter operating in current transformer (CT) and current and voltage transformer (CT-VT) configuration. It measures active, reactive and apparent energy.
Main characteristics. Rated voltage Un from 57.7 V to 240 V with a voltage range of 80% Un to 115% Un, rated frequency 50/60 Hz, reference current Ib of 1 A or 1.5 A, maximum current Imax of 6 A or 10 A, minimum current Imin of 0.01 A and starting current Ist of 0.1% Ib. Accuracy is class C/0.5S for active energy and class 2.0 for reactive energy. The meter constant is 10000 imp/kWh and 10000 imp/kvarh, indicated by an LED.
Display and backup power. 8-digit LCD with configurable decimal place and backlight. Backup power is provided by a replaceable battery and an internal super capacitor. The meter includes an RTC with clock accuracy according to IEC 62054-21.
Connectivity. Two RS485 ports in RJ45 format with 12 V power output, max 5 W, one optical port and a module compartment accepting a cellular, RF, PLC or LoRa module. The communication protocol is DLMS/COSEM with data transport encryption (Suite 0). One signal input, two signal outputs and one control output complete the I/O interface.
Consumption, environment and dimensions. Voltage circuit consumption below 2 W / 10 VA and current circuit consumption below 1 VA. Operating range -25 to 75 °C, storage range -40 to 85 °C, protection degree IP 54. Dimensions 290.1 × 178.0 × 75.0 mm for a weight of about 1.4 kg.
Standards and integration. Compliant with EN 50470-1, EN 50470-3, IEC 62052-11, IEC 62053-22/23, IEC 62056-21, IEC 62056-61 and IEC 62059-31. Suited to metering installations and remote supervision through the DLMS/COSEM protocol and the RS485 ports. Available on quotation from Atlas Electronics.
The Reallin E3016-SA three-phase four-wire meter measures active, reactive and apparent energy in CT and CT-VT configuration, with DLMS/COSEM communication.
Operating Temperature-25~75℃
Voltage Range80%Un~115%Un
Current Circuit Power Consumption<1VA
Maximum current Imax6A or 10A
Minimum Current (Imin)0.01A
2. Datasheet extract (recorded values)
Parameter
Value
Accuracy
Class C/0.5S for active; Class 2.0 for reactive
Backup power supply
Replaceable battery and Internal super capacitor
Communication Protocol
DLMS/COSEM, Support data transportation encryption (Suite 0)
Current Circuit Power Consumption
<1VA
Dimension(LxWxD)
290.1 × 178.0 ×75.0mm
Ingress Protection
IP 54
LCD display
8 digits with configurable decimal place, backlight supported
Maximum current Imax
6A or 10A
Minimum Current (Imin)
0.01A
Operating Temperature
-25~75℃
Pulsating(meter constant)
10000imp/kWh;10000imp/kvarh
Rated Frequency Fn
50/60Hz
Rated Voltage Un
57.7V~240V
Reference current Ib
1A, 1.5A
Starting Current (Ist)
0.1%Ib
Storage Temperature
-40~85℃
Type
Three Phase Four Wire CT/CT-VT Operated Meter
Voltage Circuit Power Consumption
<2W/10VA
Voltage Range
80%Un~115%Un
Weight
About 1.4kg
Integration
Points to check before using 195160791 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -25~75℃ — check it against the installation environment.
Power and communication
Backup power supply
Replaceable battery and Internal super capacitor
Current Circuit Power Consumption
<1VA
Maximum current Imax
6A or 10A
Minimum Current (Imin)
0.01A
Rated Voltage Un
57.7V~240V
Reference current Ib
1A, 1.5A
Starting Current (Ist)
0.1%Ib
Voltage Circuit Power Consumption
<2W/10VA
Voltage Range
80%Un~115%Un
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -25~75℃ — check it against the installation environment.
Applications and use cases
Architectures in which 195160791 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Solar production, storage and charging points on one site are often managed separately. Inverters, batteries, MPPT controllers, meters and chargers form a local energy system that shares production between users
To check
Regulatory framework for collective self-consumption in the country
Energy management system steering storage and charging
Metering accuracy for sharing between participants
Associated system blocks
ProductionStorageMeteringCharging
Need a complete solution?
Send a request for 195160791 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productReallin
195160791
Three-phase four-wire energy meter for CT and CT-VT operation
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details