Smart X96-5A – MID three-phase panel-mounted multifunction energy meter

MID three-phase panel-mounted multifunction energy meter

Three-Phase Energy Meters

  • -25 to 55°C
  • 9999A
  • 0.25A
  • 5A
Manufacturer part number
MID-THREE-PHASE-PANEL-MOUNTED-MULTIFUNCTION-PANEL-METER-FOR-PANEL-BOARD
Manufacturer
Eastron
Operating Temperature
-25 to 55°C
Input-Current — Max Current
9999A

MID-certified three-phase multifunction panel meter for electricity distribution. The Eastron Smart X96-5A measures voltage, current, power, energy and harmonics, with an RS485 Modbus RTU output.

Product overview

Overview. The Eastron Smart X96-5A is a MID three-phase panel-mounted multifunction energy meter for electricity distribution. It measures and displays the characteristics of 1P2W, 3P4W and 3P3W systems, including voltage, current, frequency, active and reactive power, imported and exported active and reactive energy, and harmonics up to the 63rd order.

Main characteristics. Self-powered from any of the three phases. High-definition LCD with programmable backlight, readable from all viewing angles, with a bar graph showing the load percentage on the three phases. RMS measurement including harmonics, THD of 2% up to the 63rd harmonic. Rated current of 5 A, measurable from 0.25 A to 9999 A.

Accuracy. Active energy compliant with IEC 62053-22 Class 0.5S, reactive energy compliant with IEC 62053-24 at 1.0% of range maximum. Current and voltage at 0.5% of range maximum, frequency at 0.2% of mid-frequency.

Communication and outputs. RS485 port with Modbus RTU, 2-wire half-duplex, addresses 1 to 247, baud rates from 2400 to 38400 bps, parity none, even or odd, 1 or 2 stop bits. Two S0 pulse outputs: output 1 configurable at 0.01, 0.1, 1, 10 or 100 kWh/kVArh, output 2 fixed at 3200 IMP/kWh.

Environment and installation. 96 x 96 mm case, 92 mm depth, 420 g, IP51 front display protection. Operating temperature -25 to 55 °C, storage -40 to 70 °C, humidity below 95% RH at 50 °C non-condensing, altitude 2000 m. Self-extinguishing UL 94 V-0 case material. Push-in panel mounting with shrouded screw-clamp terminals.

Typical use. Energy measurement and monitoring in distribution boards, with data transmitted to a supervision system or PLC via Modbus RTU.

See all specifications

Highlights

  • Altitude: 2000m
  • Communication Address: 1 to 247
  • Communication — Baud rate: 2400,4800, 9600, 19200, 38400 bps
  • Communication — Pariy: None (default), Even, Odd
  • Communication — RS485 port: Modbus RTU (RS485)
  • Communication — Stop Bit: 1 or 2

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -25 to 55°C — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.