S6526XE-HI
Advanced 10GE Layer 3 aggregation switch, 32 SFP+ and 6 QSFP28 ports

- VLAN interface
- 4K
- Flash
- 4GB
- Operating/Storage Humidity
- 5% RH to 95% RH, non-condensing
- SDRAM
- 4GB
Advanced 10GE Layer 3 aggregation switch, 32 SFP+ and 6 QSFP28 ports
H3C S6526XE-HI Layer 3 aggregation switch with 10GE SFP+ ports and 40G/100G QSFP28 uplinks, designed for aggregation layer and core network deployments.
Overview. The H3C S6526XE-HI is a 10GE Layer 3 aggregation switch, available as the 32-port SFP+ 1G/10G with 6 QSFP28 40G/100G version (reference LS-6526XE-32X6CC-HI) or the 48-port SFP+ 1G/10G with 6 QSFP28 40G/100G version (reference LS-6526XE-48X6CC-HI), each with one expansion slot and power supplies not included.
Main characteristics. Switching capacity of 2.56 Tbps, port switching capacity of 2240 Gbps, packet forwarding rate of 1002 Mpps, 32 MB packet buffer, 4 GB Flash and 4 GB SDRAM, quad-core CPU at 2 GHz. Latency below 3 µs in 10GE and below 1 µs in 100GE. MAC address table of 281K entries and IPv4 routing table of 351K entries.
Interfaces and connectivity. Static and dynamic link aggregation, LACP, 10GE/25G/40GE/100GE port aggregation, S-MLAG and M-LAG. IRF 2 stacking with convergence within 50 ms and maximum stacking bandwidth of 600 Gbps, stacking through standard Ethernet ports. Static routing, RIP, OSPF, IS-IS and BGP, with IPv4/IPv6 dual stack, ECMP and PBR. MPLS support including LDP, VRF, MPLS L2VPN and L3VPN, and MPLS TE, plus Segment Routing SR-MPLS. Multicast with PIM-DM, PIM-SM, PIM-SSM, IGMP and MLD. OpenFlow 1.3 support.
Lossless network. PFC, ECN, IPCC and iNOF features for lossless networks.
Power and environment. Two power supply slots in 1+1 hot-swappable redundancy, 450 W AC or DC modules, AC input range of 100 to 240 VAC. Static consumption of 89 W with single AC supply. Four N+1 hot-swappable fan trays. Operating temperature from -5 °C to 45 °C.
Typical uses. Aggregation layer of an enterprise or campus network, connection of servers at 10GE and uplinks at 40G or 100G, and integration into a core network architecture through dynamic routing and MPLS.
Integration and management. Automatic configuration by server or USB, out-of-band management through an RJ45 port, RJ45 and Type-C console ports, programmability via NETCONF, Restful APIs, Python, Ansible and TCL. Optional S5000 SecBlade IV firewall module.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for S6526XE-HI, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Automatic Configuration | Server-based automatic configuration; USB-based automatic configuration |
| Cable — LSTM1STK | SFP+ Cable 5m |
| Cable — LSWM1QSTK0 | 40G QSFP+ Cable 1m |
| Cable — LSWM1QSTK1 | 40G QSFP+ Cable 3m |
| Cable — LSWM1QSTK2 | 40G QSFP+ Cable 5m |
| Cable — LSWM1STK | SFP+ Cable 0.65m |
| Cable — LSWM2STK | SFP+ Cable 1.2m |
| Cable — LSWM3STK | SFP+ Cable 3m |
| Cable — QSFP-100G-D-AOC-10M | 100G QSFP28 to 100G QSFP28 10m Active Optical Cable |
| Cable — QSFP-100G-D-AOC-20M | 100G QSFP28 to 100G QSFP28 20m Active Optical Cable |
| Cable — QSFP-100G-D-CAB-1M | 100G QSFP28 to 100G QSFP28 1m Passive Cable |
| Cable — QSFP-100G-D-CAB-3M | 100G QSFP28 to 100G QSFP28 3m Passive Cable |
| Cable — QSFP-100G-D-CAB-5M | 100G QSFP28 to 100G QSFP28 5m Passive Cable |
| Cable — QSFP-40G-D-AOC-20M | 40G QSFP+ to 40G QSFP+ 20m Active Optical Cable |
| Cable — QSFP-40G-D-AOC-7M | 40G QSFP+ to 40G QSFP+ 7m Active Optical Cable |
| Cable — SFP-STACK-Kit | SFP Stacking Cable (150cm,including two 1000BASE-T SFP module and one stacking cable) |
| Console Ports | 1 RJ45 and 1 Type-C |
| CPU | Quad core, 2GHz |
| Dimensions H*W*D | 44 × 440 × 400 mm (1.73 × 17.32 × 15.75 in) |
| EMC | FCC Part 15 Subpart B CLASS A; ICES-003 CLASS A; VCCI CLASS A; CISPR 32 CLASS A; EN 55032 CLASS A; CISPR 35; AS/NZS CISPR 32; EN 55035; EN 61000-3-2; EN 61000-3-3; ETSI EN 300 386 |
| Ethernet link aggregation | static aggregation; dynamic aggregation; 10GE/25G/40GE/100GE port aggregation; LACP (Link Aggregation Control Protocol); S-MLAG; M-LAG (Multichassis Link Aggregation) |
| Fan — LSPM1FANSA-SN | H3C Fan Module (Fan Panel Side Intake Airflow) |
| Fan — LSPM1FANSB-SN | H3C Fan Module (Fan Panel Side Exhaust Airflow) |
| Fan trays | 4, N+1 hot swappable |
| Flash | 4GB |
| Input voltage range | AC:; Rated: 100 VAC to 240 VAC @ 50 Hz/60 Hz; Max: 90 VAC to 264 VAC @ 47 Hz to 63 Hz |
| Intelligent Lossless Network | PFC (Priority-based Flow Control); ECN (Explicit Congestion Notification); IPCC (Intelligent Proactive Congestion Control); iNOF (Intelligent Lossless NVMe Over Fabric) |
| IPv4 ARP entries(max) | 64K |
| IPv4 routing entries(max) | 351K |
| IPv6 ND entries(max) | 48K |
| IPv6 unicast routing entries(max) | 130K |
| ITU | ITU-T Y.1731; ITU-T Rec G.8032/Y.1344 Mar. 2010 |
| Latency | 10GE:<3 (64byte/us); 100GE:<1 (64byte/us) |
| Latency (64byte LIFO) | 10GE:<3μs; 100GE:<1μs |
| MAC address entries(max) | 281K |
| Management Ethernet ports | 1 RJ45 port (Out of Band) |
| Max Stacking Bandwidth | 600Gbps |
| Modules — LSPM6FWDB | H3C S5000 Series SecBlade IV Next Generation Firewall B Module |
| Modules — LSWM2QP2P | 2-Port 40G QSFP Plus Interface Module |
| Modules — LSWM2SP8P | 8-Port 10G SFP Plus Interface Module |
| Modules — LSWM2ZQP2P | 2-Port 100G QSFP28 Interface Module |
| Modules — LSWM2ZSP8P | 8-Port 25G SFP28 Interface Module |
| Modules — LSWM4SP8PM | 8-Port 10G SFP Plus with MACSec Interface Module |
| MPLS | Static LSP (label switched path); Static CRLSP; LDP (Label Distribution Protocol); IPv6 LDP; Tunnel policy; VRF; MPLS L2VPN; MPLS L3VPN; MPLS Ping/Tracert; MCE (Multi-VPN Instance Customer Edge); IPv6 MCE; MPLS OAM; MPLS TE |
| MTBF(year) | 116.18 |
| Multicast | PIM-DM, PIM-SM, PIM-SSM, and Any-RP; PIM snooping; MSDP (Multicast Source Discovery Protocol); IGMPv1/IGMPv2/IGMPv3; IGMP proxying; IGMP Snooping; IGMP snooping proxying; IGMP Filter and IGMP Fast leave; IPv6 PIM-DM, PIM-SM, PIM-SSM, and Any-RP; IPv6 PIM snooping; MLDv1/MLDV2; MLD proxying; MLD Snooping; MLD snooping proxying; Multicast routing and forwarding; Multicast VLAN; MVPN (Multicast VPN); Multicast policy and Multicast QoS |
| OpenFlow | OpenFlow 1.3; Multiple controllers (EQUAL, master/slave); Multiple tables flow; Group table |
| Operating/Storage Humidity | 5% RH to 95% RH, non-condensing |
| Operating Temperature | -5ºC to 45ºC (23ºF to 113ºF); From -60m to 5000m altitude: From 0m, the maximum operating temperature reduce by 0.33ºC for every time 100 the altitude increases by 100m. |
| Organization | Standards and protocols |
| Packet Buffer | 32M |
| Packet Forwarding Rate | 1002Mpps |
| Port Switching Capacity | 2240Gbps |
| Power consumption (static); Data collection standard: no load | Single AC: 89W; Dual AC: 90W; Single DC: 86W; Dual DC: 98W |
| Power supply — PSR450-12A1-GL | 450W AC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Power supply — PSR450-12A-GL | 450W AC Power Supply Module (Power Panel Side Intake Airflow) |
| Power supply — PSR450-12D | 450W DC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Power supply slots | 2, 1+1 hot swappable |
| Product code — LS-6526XE-32X6CC-HI | H3C S6526XE-32X6CC-HI L3 Ethernet Switch with 32*1G/10G SFP+ Ports, 6*40G/100G QSFP28 Ports, and 1*Slot, Without Power Supplies |
| Product code — LS-6526XE-48X6CC-HI | H3C S6526XE-48X6CC-HI L3 Ethernet Switch with 48*1G/10G SFP+ Ports, 6*40G/100G QSFP28 Ports, and 1*Slot, Without Power Supplies |
| Programmability and Automation | Ansible; Auto DevOps by using Python, NETCONF, TCL, and Restful APIs for automated network programming |
| RoHS | EU RoHS2.0 Directive; China RoHS 2.0 |
| Routing | Static routing, RIP, OSPF, IS-IS, and BGP; IPv4/IPv6 dual stack; IPv4/IPv6 ECMP (Equal-cost multi-path routing); IPv4/IPv6 PBR (Policy-based routing); IPv4/IPv6 Routing policy; IPv6 static routing, RIPng, OSPFv3, IS-ISv6, and BGP4+; Pingv6, Telnetv6, FTPv6, TFTPv6, DNSv6, ICMPv6; Dual-stack PBR |
| Safety | UL 62368-1; CSA C22.2 No. 62368-1-14; IEC 62368-1; EN 62368-1; EN 60825-1; AS/NZS 62368-1; GB 4943.1 |
| SDRAM | 4GB |
| Segment Routing | SR-MPLS |
| Stacking | Intelligent Resilient Framework 2 (IRF 2) (fast convergence within 50ms); Distributed device management; Distributed link aggregation; Distributed resilient routing; Stacking through standard Ethernet ports; Local device stacking and remote device stacking; LACP-, BFD-, and ARP-based multi-active detection (MAD) |
| Storage Temperature | -40ºC to 70ºC (-40ºF to 158ºF) |
| System switching capacity * | 2.56Tbps |
| Transceiver — QSFP-100G-ER4L-WDM1300 | 100G QSFP28 Optical Transceiver Module (1310nm,40km,ER4L,WDM,LC) |
| Transceiver — QSFP-100G-eSR4-MM850 | 100G QSFP28 Optical Transceiver Module (850nm,300m OM4,eSR4,MPO) |
| Transceiver — QSFP-100G-LR4-WDM1300 | 100G QSFP28 Optical Transceiver Module(1310nm,10km,LR4,WDM,LC) |
| Transceiver — QSFP-100G-LR4L-WDM1300 | 100G QSFP28 Optical Transceiver Module (1310nm,2km,LR4L,CWDM4,LC) |
| Transceiver — QSFP-100G-SR4-MM850 | 100G QSFP28 Optical Transceiver Module (850nm,100m OM4,SR4,MPO) |
| Transceiver — QSFP-40G-BIDI-SR-MM850 | QSFP+ 40GBASE BIDI Optical Transceiver Module (850nm,100m,SR) |
| Transceiver — QSFP-40G-CSR4-MM850 | QSFP+ 40GBASE Optical Transceiver Module (850nm,300m,CSR4,Support 40G to 4*10G) |
| Transceiver — QSFP-40G-ER4-WDM1300 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,40km,ER4,LC) |
| Transceiver — QSFP-40G-LR4-WDM1300 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,10km,LR4,LC) |
| Transceiver — QSFP-40G-LR4L-WDM1300 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,2km,LR4L,LC) |
| Transceiver — QSFP-40G-SR4-MM850 | QSFP+ 40GBASE Optical Transceiver Module (850nm,100m,SR4,Support 40G to 4*10G) |
| Transceiver — SFP-10GE-T | SFP+ 10GE Copper Interface Transceiver Module(Cat6a/Cat7,30m,RJ45) |
| Transceiver — SFP-GE-LH100-SM1550 | 1000BASE-LH100 SFP Transceiver, Single Mode (1550nm, 100km, LC) |
| Transceiver — SFP-GE-LH40-SM1310 | 1000BASE-LH40 SFP Transceiver, Single Mode (1310nm, 40km, LC) |
| Transceiver — SFP-GE-LH40-SM1550 | 1000BASE-LH40 SFP Transceiver, Single Mode (1550nm, 40km, LC) |
| Transceiver — SFP-GE-LH80-SM1550 | 1000BASE-LH80 SFP Transceiver, Single Mode (1550nm, 80km, LC) |
| Transceiver — SFP-GE-LH80-SM1550-D | 1000BASE-LH80 SFP Transceiver, Single Mode (1550nm, 80km, LC) |
| Transceiver — SFP-GE-LX-SM1310-A | 1000BASE-LX SFP Transceiver, Single Mode (1310nm, 10km, LC) |
| Transceiver — SFP-GE-LX-SM1310-BIDI | 1000BASE-LX BIDI SFP Transceiver, Single Mode (TX1310/RX1490, 10km, LC) |
| Transceiver — SFP-GE-LX-SM1310-D | 1000BASE-LX SFP Transceiver, Single Mode (1310nm, 10km, LC) |
| Transceiver — SFP-GE-LX-SM1490-BIDI | 1000BASE-LX BIDI SFP Transceiver, Single Mode (TX1490/RX1310, 10km, LC) |
| Transceiver — SFP-GE-SX-MM850-A | 1000BASE-SX SFP Transceiver, Multi-Mode (850nm, 550m, LC) |
| Transceiver — SFP-GE-SX-MM850-D | 1000BASE-SX SFP Transceiver, Multi-Mode (850nm, 550m, LC) |
| Transceiver — SFP-GE-T | SFP GE Copper Interface Transceiver Module (100m,RJ45) |
| Transceiver — SFP-GE-T-D | SFP GE Copper Interface Transceiver Module (100m,RJ45) |
| Transceiver — SFP-XG-CPRI-LR-SM1310 | SFP+ 10G CPRI Optical Transceiver Module(-40ºC to 85ºC,1310nm,10km,LC) |
| Transceiver — SFP-XG-LH40-SM1550 | SFP+ Module(1550nm,40km,LC) |
| Transceiver — SFP-XG-LH80-SM1490-BIDI | 10G SFP+ BIDI Optical Transceiver Module (TX1490nm/RX1550nm,80km,LC) |
| Transceiver — SFP-XG-LH80-SM1550-BIDI | 10G SFP+ BIDI Optical Transceiver Module (TX1550nm/RX1490nm,80km,LC) |
| Transceiver — SFP-XG-LH80-SM1550-D | SFP+ Module(1550nm,80km,LC) |
| Transceiver — SFP-XG-LX-SM1310 | SFP+ Module(1310nm,10km,LC) |
| Transceiver — SFP-XG-LX-SM1310-D | SFP+ Module(1310nm,10km,LC) |
| Transceiver — SFP-XG-LX-SM1310-E | SFP+ Module(1310nm,10km,LC) |
| Transceiver — SFP-XG-SX-MM850-A | SFP+ Module(850nm,300m,LC) |
| Transceiver — SFP-XG-SX-MM850-D | SFP+ Module(850nm,300m,LC) |
| Transceiver — SFP-XG-SX-MM850-E | SFP+ Module(850nm,300m,LC) |
| Visualization | gRPC (Google remote procedure call); INT (Inband Telemetry); Flow group |
| VLAN interface | 4K |
| VLAN Table | 4K |
| VXLAN | VXLAN L2 switching; VXLAN L3 routing; Centralized VXLAN gateway; Distributed VXLAN gateway; VXLAN M-LAG; VXLAN-DCI; OVSDB (Open vSwitch Database); VXLAN VTEP; MP-BGP EVPN control plane; EVPN VXLAN; EVPN M-LAG; EVPN VPLS; EVPN VPWS; MVXLAN |
| Weight | ≤ 7.9 kg |
No specification matches.
Last verification : 2026-11-06
Official documents and the technical data recorded for S6526XE-HI. For a missing document or a specific revision, our experts send it to you.
H3C S6526XE-HI Layer 3 aggregation switch with 10GE SFP+ ports and 40G/100G QSFP28 uplinks, designed for aggregation layer and core network deployments.
| Parameter | Value |
|---|---|
| Automatic Configuration | Server-based automatic configuration; USB-based automatic configuration |
| Cable — LSTM1STK | SFP+ Cable 5m |
| Cable — LSWM1QSTK0 | 40G QSFP+ Cable 1m |
| Cable — LSWM1QSTK1 | 40G QSFP+ Cable 3m |
| Cable — LSWM1QSTK2 | 40G QSFP+ Cable 5m |
| Cable — LSWM1STK | SFP+ Cable 0.65m |
| Cable — LSWM2STK | SFP+ Cable 1.2m |
| Cable — LSWM3STK | SFP+ Cable 3m |
| Cable — QSFP-100G-D-AOC-10M | 100G QSFP28 to 100G QSFP28 10m Active Optical Cable |
| Cable — QSFP-100G-D-AOC-20M | 100G QSFP28 to 100G QSFP28 20m Active Optical Cable |
| Cable — QSFP-100G-D-CAB-1M | 100G QSFP28 to 100G QSFP28 1m Passive Cable |
| Cable — QSFP-100G-D-CAB-3M | 100G QSFP28 to 100G QSFP28 3m Passive Cable |
| Cable — QSFP-100G-D-CAB-5M | 100G QSFP28 to 100G QSFP28 5m Passive Cable |
| Cable — QSFP-40G-D-AOC-20M | 40G QSFP+ to 40G QSFP+ 20m Active Optical Cable |
| Cable — QSFP-40G-D-AOC-7M | 40G QSFP+ to 40G QSFP+ 7m Active Optical Cable |
| Cable — SFP-STACK-Kit | SFP Stacking Cable (150cm,including two 1000BASE-T SFP module and one stacking cable) |
| Console Ports | 1 RJ45 and 1 Type-C |
| CPU | Quad core, 2GHz |
| Dimensions H*W*D | 44 × 440 × 400 mm (1.73 × 17.32 × 15.75 in) |
| EMC | FCC Part 15 Subpart B CLASS A; ICES-003 CLASS A; VCCI CLASS A; CISPR 32 CLASS A; EN 55032 CLASS A; CISPR 35; AS/NZS CISPR 32; EN 55035; EN 61000-3-2; EN 61000-3-3; ETSI EN 300 386 |
| Ethernet link aggregation | static aggregation; dynamic aggregation; 10GE/25G/40GE/100GE port aggregation; LACP (Link Aggregation Control Protocol); S-MLAG; M-LAG (Multichassis Link Aggregation) |
| Fan — LSPM1FANSA-SN | H3C Fan Module (Fan Panel Side Intake Airflow) |
| Fan — LSPM1FANSB-SN | H3C Fan Module (Fan Panel Side Exhaust Airflow) |
| Fan trays | 4, N+1 hot swappable |
| Flash | 4GB |
| Input voltage range | AC:; Rated: 100 VAC to 240 VAC @ 50 Hz/60 Hz; Max: 90 VAC to 264 VAC @ 47 Hz to 63 Hz |
| Intelligent Lossless Network | PFC (Priority-based Flow Control); ECN (Explicit Congestion Notification); IPCC (Intelligent Proactive Congestion Control); iNOF (Intelligent Lossless NVMe Over Fabric) |
| IPv4 ARP entries(max) | 64K |
| IPv4 routing entries(max) | 351K |
| IPv6 ND entries(max) | 48K |
| IPv6 unicast routing entries(max) | 130K |
| ITU | ITU-T Y.1731; ITU-T Rec G.8032/Y.1344 Mar. 2010 |
| Latency | 10GE:<3 (64byte/us); 100GE:<1 (64byte/us) |
| Latency (64byte LIFO) | 10GE:<3μs; 100GE:<1μs |
| MAC address entries(max) | 281K |
| Management Ethernet ports | 1 RJ45 port (Out of Band) |
| Max Stacking Bandwidth | 600Gbps |
| Modules — LSPM6FWDB | H3C S5000 Series SecBlade IV Next Generation Firewall B Module |
| Modules — LSWM2QP2P | 2-Port 40G QSFP Plus Interface Module |
| Modules — LSWM2SP8P | 8-Port 10G SFP Plus Interface Module |
| Modules — LSWM2ZQP2P | 2-Port 100G QSFP28 Interface Module |
| Modules — LSWM2ZSP8P | 8-Port 25G SFP28 Interface Module |
| Modules — LSWM4SP8PM | 8-Port 10G SFP Plus with MACSec Interface Module |
| MPLS | Static LSP (label switched path); Static CRLSP; LDP (Label Distribution Protocol); IPv6 LDP; Tunnel policy; VRF; MPLS L2VPN; MPLS L3VPN; MPLS Ping/Tracert; MCE (Multi-VPN Instance Customer Edge); IPv6 MCE; MPLS OAM; MPLS TE |
| MTBF(year) | 116.18 |
| Multicast | PIM-DM, PIM-SM, PIM-SSM, and Any-RP; PIM snooping; MSDP (Multicast Source Discovery Protocol); IGMPv1/IGMPv2/IGMPv3; IGMP proxying; IGMP Snooping; IGMP snooping proxying; IGMP Filter and IGMP Fast leave; IPv6 PIM-DM, PIM-SM, PIM-SSM, and Any-RP; IPv6 PIM snooping; MLDv1/MLDV2; MLD proxying; MLD Snooping; MLD snooping proxying; Multicast routing and forwarding; Multicast VLAN; MVPN (Multicast VPN); Multicast policy and Multicast QoS |
| OpenFlow | OpenFlow 1.3; Multiple controllers (EQUAL, master/slave); Multiple tables flow; Group table |
| Operating/Storage Humidity | 5% RH to 95% RH, non-condensing |
| Operating Temperature | -5ºC to 45ºC (23ºF to 113ºF); From -60m to 5000m altitude: From 0m, the maximum operating temperature reduce by 0.33ºC for every time 100 the altitude increases by 100m. |
| Organization | Standards and protocols |
| Packet Buffer | 32M |
| Packet Forwarding Rate | 1002Mpps |
| Port Switching Capacity | 2240Gbps |
| Power consumption (static); Data collection standard: no load | Single AC: 89W; Dual AC: 90W; Single DC: 86W; Dual DC: 98W |
| Power supply — PSR450-12A1-GL | 450W AC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Power supply — PSR450-12A-GL | 450W AC Power Supply Module (Power Panel Side Intake Airflow) |
| Power supply — PSR450-12D | 450W DC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Power supply slots | 2, 1+1 hot swappable |
| Product code — LS-6526XE-32X6CC-HI | H3C S6526XE-32X6CC-HI L3 Ethernet Switch with 32*1G/10G SFP+ Ports, 6*40G/100G QSFP28 Ports, and 1*Slot, Without Power Supplies |
| Product code — LS-6526XE-48X6CC-HI | H3C S6526XE-48X6CC-HI L3 Ethernet Switch with 48*1G/10G SFP+ Ports, 6*40G/100G QSFP28 Ports, and 1*Slot, Without Power Supplies |
| Programmability and Automation | Ansible; Auto DevOps by using Python, NETCONF, TCL, and Restful APIs for automated network programming |
| RoHS | EU RoHS2.0 Directive; China RoHS 2.0 |
| Routing | Static routing, RIP, OSPF, IS-IS, and BGP; IPv4/IPv6 dual stack; IPv4/IPv6 ECMP (Equal-cost multi-path routing); IPv4/IPv6 PBR (Policy-based routing); IPv4/IPv6 Routing policy; IPv6 static routing, RIPng, OSPFv3, IS-ISv6, and BGP4+; Pingv6, Telnetv6, FTPv6, TFTPv6, DNSv6, ICMPv6; Dual-stack PBR |
| Safety | UL 62368-1; CSA C22.2 No. 62368-1-14; IEC 62368-1; EN 62368-1; EN 60825-1; AS/NZS 62368-1; GB 4943.1 |
| SDRAM | 4GB |
| Segment Routing | SR-MPLS |
| Stacking | Intelligent Resilient Framework 2 (IRF 2) (fast convergence within 50ms); Distributed device management; Distributed link aggregation; Distributed resilient routing; Stacking through standard Ethernet ports; Local device stacking and remote device stacking; LACP-, BFD-, and ARP-based multi-active detection (MAD) |
| Storage Temperature | -40ºC to 70ºC (-40ºF to 158ºF) |
| System switching capacity * | 2.56Tbps |
| Transceiver — QSFP-100G-ER4L-WDM1300 | 100G QSFP28 Optical Transceiver Module (1310nm,40km,ER4L,WDM,LC) |
| Transceiver — QSFP-100G-eSR4-MM850 | 100G QSFP28 Optical Transceiver Module (850nm,300m OM4,eSR4,MPO) |
| Transceiver — QSFP-100G-LR4-WDM1300 | 100G QSFP28 Optical Transceiver Module(1310nm,10km,LR4,WDM,LC) |
| Transceiver — QSFP-100G-LR4L-WDM1300 | 100G QSFP28 Optical Transceiver Module (1310nm,2km,LR4L,CWDM4,LC) |
| Transceiver — QSFP-100G-SR4-MM850 | 100G QSFP28 Optical Transceiver Module (850nm,100m OM4,SR4,MPO) |
| Transceiver — QSFP-40G-BIDI-SR-MM850 | QSFP+ 40GBASE BIDI Optical Transceiver Module (850nm,100m,SR) |
| Transceiver — QSFP-40G-CSR4-MM850 | QSFP+ 40GBASE Optical Transceiver Module (850nm,300m,CSR4,Support 40G to 4*10G) |
| Transceiver — QSFP-40G-ER4-WDM1300 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,40km,ER4,LC) |
| Transceiver — QSFP-40G-LR4-WDM1300 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,10km,LR4,LC) |
| Transceiver — QSFP-40G-LR4L-WDM1300 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,2km,LR4L,LC) |
| Transceiver — QSFP-40G-SR4-MM850 | QSFP+ 40GBASE Optical Transceiver Module (850nm,100m,SR4,Support 40G to 4*10G) |
| Transceiver — SFP-10GE-T | SFP+ 10GE Copper Interface Transceiver Module(Cat6a/Cat7,30m,RJ45) |
| Transceiver — SFP-GE-LH100-SM1550 | 1000BASE-LH100 SFP Transceiver, Single Mode (1550nm, 100km, LC) |
| Transceiver — SFP-GE-LH40-SM1310 | 1000BASE-LH40 SFP Transceiver, Single Mode (1310nm, 40km, LC) |
| Transceiver — SFP-GE-LH40-SM1550 | 1000BASE-LH40 SFP Transceiver, Single Mode (1550nm, 40km, LC) |
| Transceiver — SFP-GE-LH80-SM1550 | 1000BASE-LH80 SFP Transceiver, Single Mode (1550nm, 80km, LC) |
| Transceiver — SFP-GE-LH80-SM1550-D | 1000BASE-LH80 SFP Transceiver, Single Mode (1550nm, 80km, LC) |
| Transceiver — SFP-GE-LX-SM1310-A | 1000BASE-LX SFP Transceiver, Single Mode (1310nm, 10km, LC) |
| Transceiver — SFP-GE-LX-SM1310-BIDI | 1000BASE-LX BIDI SFP Transceiver, Single Mode (TX1310/RX1490, 10km, LC) |
| Transceiver — SFP-GE-LX-SM1310-D | 1000BASE-LX SFP Transceiver, Single Mode (1310nm, 10km, LC) |
| Transceiver — SFP-GE-LX-SM1490-BIDI | 1000BASE-LX BIDI SFP Transceiver, Single Mode (TX1490/RX1310, 10km, LC) |
| Transceiver — SFP-GE-SX-MM850-A | 1000BASE-SX SFP Transceiver, Multi-Mode (850nm, 550m, LC) |
| Transceiver — SFP-GE-SX-MM850-D | 1000BASE-SX SFP Transceiver, Multi-Mode (850nm, 550m, LC) |
| Transceiver — SFP-GE-T | SFP GE Copper Interface Transceiver Module (100m,RJ45) |
| Transceiver — SFP-GE-T-D | SFP GE Copper Interface Transceiver Module (100m,RJ45) |
| Transceiver — SFP-XG-CPRI-LR-SM1310 | SFP+ 10G CPRI Optical Transceiver Module(-40ºC to 85ºC,1310nm,10km,LC) |
| Transceiver — SFP-XG-LH40-SM1550 | SFP+ Module(1550nm,40km,LC) |
| Transceiver — SFP-XG-LH80-SM1490-BIDI | 10G SFP+ BIDI Optical Transceiver Module (TX1490nm/RX1550nm,80km,LC) |
| Transceiver — SFP-XG-LH80-SM1550-BIDI | 10G SFP+ BIDI Optical Transceiver Module (TX1550nm/RX1490nm,80km,LC) |
| Transceiver — SFP-XG-LH80-SM1550-D | SFP+ Module(1550nm,80km,LC) |
| Transceiver — SFP-XG-LX-SM1310 | SFP+ Module(1310nm,10km,LC) |
| Transceiver — SFP-XG-LX-SM1310-D | SFP+ Module(1310nm,10km,LC) |
| Transceiver — SFP-XG-LX-SM1310-E | SFP+ Module(1310nm,10km,LC) |
| Transceiver — SFP-XG-SX-MM850-A | SFP+ Module(850nm,300m,LC) |
| Transceiver — SFP-XG-SX-MM850-D | SFP+ Module(850nm,300m,LC) |
| Transceiver — SFP-XG-SX-MM850-E | SFP+ Module(850nm,300m,LC) |
| Visualization | gRPC (Google remote procedure call); INT (Inband Telemetry); Flow group |
| VLAN interface | 4K |
| VLAN Table | 4K |
| VXLAN | VXLAN L2 switching; VXLAN L3 routing; Centralized VXLAN gateway; Distributed VXLAN gateway; VXLAN M-LAG; VXLAN-DCI; OVSDB (Open vSwitch Database); VXLAN VTEP; MP-BGP EVPN control plane; EVPN VXLAN; EVPN M-LAG; EVPN VPLS; EVPN VPWS; MVXLAN |
| Weight | ≤ 7.9 kg |
Points to check before using S6526XE-HI in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Input voltage range | AC:; Rated: 100 VAC to 240 VAC @ 50 Hz/60 Hz; Max: 90 VAC to 264 VAC @ 47 Hz to 63 Hz |
| Power consumption (static); Data collection standard: no load | Single AC: 89W; Dual AC: 90W; Single DC: 86W; Dual DC: 98W |
| Power supply — PSR450-12A1-GL | 450W AC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Power supply — PSR450-12A-GL | 450W AC Power Supply Module (Power Panel Side Intake Airflow) |
| Power supply — PSR450-12D | 450W DC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Power supply slots | 2, 1+1 hot swappable |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of S6526XE-HI can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Ethernet link aggregation": static aggregation; dynamic aggregation; 10GE/25G/40GE/100GE port aggregation; LACP (Link Aggregation Control Protocol); S-MLAG; M-LAG (Multichassis Link Aggregation).
Yes — recorded under "Automatic Configuration": Server-based automatic configuration; USB-based automatic configuration.
-5ºC to 45ºC (23ºF to 113ºF); From -60m to 5000m altitude: From 0m, the maximum operating temperature reduce by 0.33ºC for every time 100 the altitude increases by 100m. (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Advanced 10GE Layer 3 aggregation switch, 32 SFP+ and 6 QSFP28 ports

H3C Series Advanced Aggregation 10GE Switches

H3C Series Enhanced 10GE Switches

H3C Series Data Center Switches

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | S6526XE-HI |
| Manufacturer | H3C |
Core and Aggregation Switches
Gigabit Managed Layer 3 Switch with 4 SFP Ports · Ref. : DGS-3312SR
Price on request
Core and Aggregation Switches
24-port Layer 3 PoE+ switch with 2.5 GbE and 10G SFP+ · Ref. : USW-ENTERPRISE-24-POE
Price on request
Core and Aggregation Switches
IP65 high bay dual sense presence sensor HF and PIR · Ref. : HIM30-B-L2
Price on request
Core and Aggregation Switches
28-port GbE L3 aggregation switch with 4 SFP+ uplinks
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details