HXE34K – Direct or indirect three-phase energy meter with multi-tariff TOU

Direct or indirect three-phase energy meter with multi-tariff TOU

Three-Phase Energy Meters

Manufacturer part number
HXE34K
Manufacturer
Hexing

The HXE34K is a Hexing three-phase static energy meter, direct or indirect connected, measuring active and reactive energy on two- or three-phase power supply systems.

Product overview

Hexing HXE34K. three-phase polyphase static energy meter, direct or indirect connected, designed to measure active and reactive energy.

Measurement. The meter measures active energy in class 1 for direct connection and class 0.5S for indirect connection, and reactive energy in class 2 or class 1. It suits 3P4W, 3P3W or 2P3W wiring at 50 Hz or 60 Hz, with an operating voltage range of 70% to 120% Un.

Electrical characteristics. Base current of 5 A for direct connection and 1 A for indirect connection, maximum current of 100 A or 120 A for direct connection and 10 A for indirect connection. Starting current is at most 0.4% Ib for active energy and 0.5% Ib for reactive energy in direct connection. Power consumption of the voltage circuit is at most 1 W active and 2 VA apparent, and that of the current circuit at most 0.1 VA.

Communication. Optical port compliant with IEC62056-21C or IEC62056-21E (DLMS). Optional RS485 interface with IEC62056-21C or HDLC (DLMS) protocol, and optional RF module with IEC62056-21C protocol.

Anti-tamper protection. Five sealing locations, meter cover and terminal cover open detection, reverse current and reverse phase sequence detection, with optional strong magnetic field and bypass detection. Storage of up to 200 time-stamped event records, with LED or LCD alarm indication.

Demand monitoring. Optional demand function with block or sliding window methods, programmable demand interval (typically 5, 10, 15, 30 or 60 minutes), historical data up to 16 months and scheduled or manual reset.

Environmental resistance. IP54 enclosure rating, operating temperature from -40 ℃ to 70 ℃, humidity up to 95% non-condensing. Electrostatic discharge immunity of 15 kV air and 8 kV contact, electrical fast transient of 4 kV and surge immunity of 4 kV, in line with IEC62052-11 and IEC62053-21.

Dimensions and weight. 216 × 173 × 65 mm with extended cover, 238 × 173 × 65 mm with long cover, 180 × 173 × 65 mm with short cover. Approximately 1.1 kg in 3P4W direct and approximately 0.9 kg in 2P3W direct.

Available on quotation from Atlas Electronics.

Typical applications

Derived from the part category, not a compatibility statement.