PSD400
Inverter Data Logger with Wi-Fi and RS485

- Operating Temperature
- -30°C ~ +65°C
- Communication interface
- RS-485
- Input Voltage
- DC 5V
- Operating Power Consumption
- 5W
Inverter Data Logger with Wi-Fi and RS485
The PSD400.R210 is a Hexing data logger that collects operating data from Livoltek inverters over RS-485 and forwards it by Wi-Fi, Ethernet or Bluetooth for power station monitoring.
Hexing PSD400.R210. The Hexing PSD400.R210 is a plug-in data logger for collecting inverter data in power stations. It is identified by the technical reference PSD400.R210 and marketed as Data Logger PSD400, or PSD400-WiNet.
Main characteristics. The data acquisition terminal records in real time the operating status and generation data of the inverters, with a collection interval of 5 minutes. It supports Livoltek Inverter devices.
Interfaces and connectivity. The downlink to the inverters uses RS-485. Uplink communication is provided by Wi-Fi (2.4 GHz, 802.11 b/g/n, STA/AP/STA+AP modes), one 10/100 Mbps Ethernet port with auto-negotiation (maximum distance 100 m) and Bluetooth BLE 4.2 at 1 Mbps. Two LED indicators show the device status.
Power and environment. It is powered from DC 5 V and consumes 5 W. The operating temperature range is -30 °C to +65 °C, storage -40 °C to +70 °C, operating humidity 5% to 95% non-condensing, operating altitude up to 3000 m. The enclosure measures 46.5 × 32.5 × 135 mm and is rated IP65.
Typical uses and integration. This logger suits monitoring and operations and maintenance (O&M) of photovoltaic power stations, linking inverters to monitoring systems over the local or remote network. The manufacturer indicates DHCP automatic network configuration, local or remote upgrades, automatic reconnection and 7-day offline data caching. The product is available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for PSD400, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Mounting | Plug-in |
| Bluetooth Communication | BLE 4.2, 1Mbps |
| Communication interface | RS-485 |
| Data collection interval | 5 minutes |
| Dimensions (L × W × H) | 46.5 × 32.5 × 135 mm |
| Ethernet Communication | 1 port, 10/100Mbps auto-negotiation, max distance 100m |
| Indicator Lights | LED × 2 |
| Input Voltage | DC 5V |
| Operating Altitude | ≤ 3000m |
| Operating Humidity | 5% - 95% (non-condensing) |
| Operating Power Consumption | 5W |
| Operating Temperature | -30°C ~ +65°C |
| Protection rating | IP65 |
| Storage Temperature | -40°C ~ +70°C |
| Supported Device Type | Livoltek Inverter |
| Technical Specifications | PSD400.R210 |
| WLAN Communication | 2.4GHz / 802.11 b/g/n, supports STA/AP/STA+AP modes |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for PSD400. For a missing document or a specific revision, our experts send it to you.
The PSD400.R210 is a Hexing data logger that collects operating data from Livoltek inverters over RS-485 and forwards it by Wi-Fi, Ethernet or Bluetooth for power station monitoring.
| Parameter | Value |
|---|---|
| Mounting | Plug-in |
| Bluetooth Communication | BLE 4.2, 1Mbps |
| Communication interface | RS-485 |
| Data collection interval | 5 minutes |
| Dimensions (L × W × H) | 46.5 × 32.5 × 135 mm |
| Ethernet Communication | 1 port, 10/100Mbps auto-negotiation, max distance 100m |
| Indicator Lights | LED × 2 |
| Input Voltage | DC 5V |
| Operating Altitude | ≤ 3000m |
| Operating Humidity | 5% - 95% (non-condensing) |
| Operating Power Consumption | 5W |
| Operating Temperature | -30°C ~ +65°C |
| Protection rating | IP65 |
| Storage Temperature | -40°C ~ +70°C |
| Supported Device Type | Livoltek Inverter |
| Technical Specifications | PSD400.R210 |
| WLAN Communication | 2.4GHz / 802.11 b/g/n, supports STA/AP/STA+AP modes |
Points to check before using PSD400 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Input Voltage | DC 5V |
| Operating Power Consumption | 5W |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of PSD400 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication interface": RS-485.
Yes — recorded under "Bluetooth Communication": BLE 4.2, 1Mbps.
Yes — recorded under "Ethernet Communication": 1 port, 10/100Mbps auto-negotiation, max distance 100m.
-30°C ~ +65°C (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Inverter Data Logger with Wi-Fi and RS485

Data Logger

SDLogger - Open Hardware Data Logger

Data Logger Ultrasonic River Flow Meter Open Channel Flowmeters

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | PSD400 |
| Manufacturer | Hexing |
Data Loggers
IoT edge gateway data logger with RS485 and 4G · Ref. : 4G/WIFI/GPS/RS232/RS485
Price on request
Data Loggers
RS485 data logger for solar systems · Ref. : ELOG01-G3
Price on request
Data Loggers
Long-duration data logger with continuous sampling for oscilloscope
Price on request
Data Loggers
3-channel IEPE accelerometer and 1-channel thermistor data logger
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details