Hexing HXE12-ES single-phase static energy meter for residential installations, direct-connected, active energy accuracy class 1 and 60 A maximum current.
Temperature — Operating Temperature-40℃~70℃
Operating Voltage Range90%-110%Un
Storage & Transport Temp. Range-40℃~70℃
Current — Base Current5A
Current Circuit<4 VA
Maximum Current60A
Product overview
Overview. The Hexing HXE12-ES single-phase static energy meter is a next-generation meter designed for residential use, combining rich functionality with a cost-effective design. It focuses on essential metering requirements.
Main characteristics. Accuracy class 1 for active energy, rated voltage of 220 V, frequency of 60 Hz ± 2%, base current of 5 A and maximum current of 60 A. Operating voltage range of 90% to 110% Un and starting current of 0.4% Ib or less for active energy.
Interfaces and connectivity. Optical and electrical pulse outputs, LCD display, reverse energy LED indicator and reverse current monitoring.
Power and environment. Voltage circuit consumption below 1.2 W, current circuit below 4 VA and voltage circuit apparent power below 10 VA. IP54 enclosure rating, humidity up to 95% relative humidity non-condensing, operating temperature -40 ℃ to 70 ℃ and storage and transport temperature -40 ℃ to 70 ℃.
Compliance and standards. Direct connection, terminals of Φ8 mm, standards IEC62052-11 and IEC62053-21. Dielectric strength of 4 kV for 1 min, impulse voltage withstand of 6 kV at 1.2/50 µs, electrostatic discharge immunity of 15 kV air discharge and 8 kV contact discharge, and electrical fast transient/burst immunity of 4 kV.
Dimensions and weight. Dimensions with extended cover of 51.1 mm x 113 mm x 109 mm (H x L x W) and net weight of approximately 0.33 kg.
Self-test and monitoring. Device self-test and bidirectional energy metering supporting single-phase two-wire (1P2W) or single-phase three-wire (1P3W) wiring configurations.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for SINGLE-PHASE-STANDARD-METER-HXE12-ES, with where it comes from. Use the filters to find one quickly.
All specifications (30)
Characteristic
Value
Accuracy Class — Active Energy
Class 1
Applications
Direct-Connected
Base
Cold Gray PC
Cover
Transparent PC
Current — Base Current
5A
Current Circuit
<4 VA
Dielectric Strength — AC Voltage Test
4kV for 1 min
Dimensions — With Extended Cover
51.1mmx113mmx109mm (H x L x W)
Electrical Fast Transient/Burst Test
4kV
Electrostatic Discharge (Air Discharge)
15kV
EMC — Electrostatic Discharge (Contact Discharge)
8kV
Enclosure — IP Rating
IP54
Frequency
60Hz ± 2%
Humidity
Up to 95% Relative Humidity (Non-condensing)
Impulse Voltage Test
1.2/50µs 6kV
Maximum Current
60A
Operating Voltage Range
90%-110%Un
Packaging:
Approx. 0.06kg
Power Consumption — Voltage Circuit (Active)
<1.2 W
Radiated RF Electromagnetic Field Immunity Test (80MHz~2000MHz)
10V/m (with load),
Standards
IEC62052-11, IEC62053-21
Starting Current
≤0.4%Ib (Active Energy)
Storage & Transport Temp. Range
-40℃~70℃
Surge Immunity Test
5kV
Temperature — Operating Temperature
-40℃~70℃
Terminal Cover
Transparent PC
Terminals
Φ8mm
Voltage Circuit (Apparent)
<10 VA
Voltage — Rated Voltage
220V
Weight — Net Weight
Approx. 0.33kg
No specification matches.
Last verification : 2026-11-02
Integration
Points to check before using SINGLE-PHASE-STANDARD-METER-HXE12-ES in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -40℃~70℃ — check it against the installation environment.
Power and communication
Current — Base Current
5A
Current Circuit
<4 VA
Dielectric Strength — AC Voltage Test
4kV for 1 min
Impulse Voltage Test
1.2/50µs 6kV
Maximum Current
60A
Operating Voltage Range
90%-110%Un
Power Consumption — Voltage Circuit (Active)
<1.2 W
Starting Current
≤0.4%Ib (Active Energy)
Voltage Circuit (Apparent)
<10 VA
Voltage — Rated Voltage
220V
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -40℃~70℃ — check it against the installation environment.
Applications and use cases
Architectures in which SINGLE-PHASE-STANDARD-METER-HXE12-ES can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Solar panels produce most when nobody is home, and the surplus goes to the grid. A battery with its inverter stores this energy and returns it in the evening, with a meter measuring what the home draws
To check
Panel power and the inverter compatibility of the battery
Usable capacity compared with the evening and night consumption
Local grid connection rules for balcony and home systems
Associated system blocks
InvertersBatteryMetering
Need a complete solution?
Send a request for SINGLE-PHASE-STANDARD-METER-HXE12-ES and the other parts of your project.
Answers to the questions that the recorded characteristics of SINGLE-PHASE-STANDARD-METER-HXE12-ES can answer. A question is not asked when nothing is recorded to answer it.
1What is the operating temperature range?
-40℃~70℃ (source: Temperature — Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details