HIITIO HCD 100A low-voltage DC contactor for switching continuous 100 A and 80 V DC circuits, intended for electric vehicles, energy storage and industrial DC control.
Operating Temperature-40°C to +60°C
Wide operating temperature range-40°C to +60°C
Coil Power ConsumptionIntermittent: 6-8W Continuous: 4-6W
Low power consumption coil6-8W (intermittent), 4-6W (continuous)
Rated Current (Ith)100A
Rated heating current100A (100% Ith)
Product overview
Overview. The HIITIO HCD 100A DC contactor is a compact low-voltage DC contactor designed for reliable switching of high currents. It supports a rated current of 100 A and a maximum contact voltage of 80 V DC on inductive load.
Main characteristics. Its contact voltage drop is below 40 mV at 100 A, which limits conduction losses. It offers a mechanical life above 300,000 cycles and an electrical life above 100,000 cycles. Its weight is 270 g.
Coil and power consumption. The coil consumes 6 to 8 W in intermittent operation and 4 to 6 W in continuous operation. The pick-up voltage is 60% Un intermittent and 66% Un continuous, the drop-out voltage 5 to 40% Un.
Environment. Operating range from -40 °C to +60 °C and storage temperature from -40 °C to +85 °C.
Typical uses. Main battery, pre-charge and charging systems for electric and hybrid vehicles, solar energy storage and battery management systems, DC motor control, telecom power systems and UPS.
HIITIO HCD 100A low-voltage DC contactor for switching continuous 100 A and 80 V DC circuits, intended for electric vehicles, energy storage and industrial DC control.
Operating Temperature-40°C to +60°C
Wide operating temperature range-40°C to +60°C
Coil Power ConsumptionIntermittent: 6-8W Continuous: 4-6W
Low power consumption coil6-8W (intermittent), 4-6W (continuous)
Points to check before using HCD 100A in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -40°C to +60°C — check it against the installation environment.
2Thermalrated operating range -40°C to +60°C — check it against the installation environment.
Power and communication
Coil Power Consumption
Intermittent: 6-8W Continuous: 4-6W
Drop-out Voltage
5-40% Un
Extremely low contact voltage drop
<40mV @ 100A
Low power consumption coil
6-8W (intermittent), 4-6W (continuous)
Max Contact Voltage
80V DC (Inductive Load)
Pick-up Voltage
Intermittent: 60% Un Continuous: 66% Un
Rated Current (Ith)
100A
Rated heating current
100A (100% Ith)
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -40°C to +60°C — check it against the installation environment.
Thermal : rated operating range -40°C to +60°C — check it against the installation environment.
Technical FAQ
Answers to the questions that the recorded characteristics of HCD 100A can answer. A question is not asked when nothing is recorded to answer it.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.