HCD 600A – High current DC contactor 600 A 80 V

High current DC contactor 600 A 80 V

Power Contactors

  • -40°C to +60°C
  • 600A (100% Ith)
  • -40°C to +85°C
  • > 100,000 cycles
Manufacturer part number
HCD600A
Manufacturer
HIITIO
Operating Temperature
-40°C to +60°C
Wide Operating Temperature
-40°C to +60°C

The HIITIO HCD 600A DC contactor is a power contactor rated at 600 A and 80 V DC maximum contact voltage for inductive loads, designed for high-power DC switching.

Product overview

Overview. The HIITIO HCD 600A DC contactor is a low voltage DC power contactor designed to switch high-current circuits. Its rated current is 600 A (100% Ith) and its maximum contact voltage is 80 V DC for inductive loads.

Main characteristics. The contactor has a contact voltage drop below 40 mV at 100 A, which limits losses in the power circuit. Its service life is over 300,000 mechanical cycles and over 100,000 electrical cycles. Contact jitter time is below 4 ms, for fast switching.

Coil and power supply. Coil power consumption is 6 to 8 W in intermittent operation and 4 to 6 W in continuous operation. Pick-up voltage is 60% Un intermittent and 66% Un continuous. Release voltage is 5 to 40% Un.

Environmental conditions. The operating temperature range is -40 °C to +60 °C and the storage temperature range is -40 °C to +85 °C. The product weighs 1470 g and its robust construction allows strong mounting.

Typical uses. This contactor suits main battery switching in electric vehicles and electric trucks, energy storage systems, high-capacity battery management systems, industrial DC power distribution and telecom and data center backup power.

See all specifications

Highlights

  • Coil Power Consumption: Intermittent: 6-8W Continuous: 4-6W
  • Efficient Coil: 6-8W (intermittent), 4-6W (continuous)
  • Electrical Life: > 100,000 cycles
  • Fast Operation: Contact jitter time <4ms
  • Low Contact Voltage Drop: <40mV @ 100A
  • Max Contact Voltage: 80V DC (Inductive Load)

Good to know before integrating

  • Thermal: rated operating range -40°C to +60°C — check it against the installation environment.
  • Thermal: rated operating range -40°C to +60°C — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Similar products

All Power Contactors
Request a quote