ZJWP125A – Low voltage DC contactor 125A with magnetic blowout

Low voltage DC contactor 125A with magnetic blowout

Power Contactors

  • -40°C to +60°C
  • 125A (100% Ith)
  • -40°C to +85°C
  • >100,000 cycles
Manufacturer part number
ZJWP125A
Manufacturer
HIITIO
Operating Temperature
-40°C to +60°C
Wide Operating Temperature
-40°C to +60°C

The HIITIO ZJWP125A is a 125A low voltage DC power contactor for switching DC circuits up to 96V with magnetic blowout.

Product overview

Overview. The HIITIO ZJWP125A is a 125A continuous-duty DC power contactor with magnetic blowout, rated for a maximum contact voltage of 96V DC with blowout and 48V DC without blowout. It is designed for high-current DC switching.

Main characteristics. The rated heating current is 125A (100% Ith). The contact voltage drop is below 40mV at 100A, and the contact jitter time is under 4ms for a fast response. The contactor weighs 398g.

Durability. Mechanical life exceeds 300,000 cycles and electrical life exceeds 100,000 cycles.

Coil power and environment. Coil consumption is 20 to 30W intermittent and 15 to 20W continuous. Pick-up voltage is 60% Un intermittent and 66% Un continuous, and release voltage is 5% to 40% Un. Operating temperature ranges from -40°C to +60°C and storage temperature from -40°C to +85°C.

Typical uses. Electric and commercial vehicles, solar energy storage systems and battery packs, battery management and pre-charge circuits, industrial automation and DC motor control, marine, RV and off-grid power systems, material handling and heavy equipment.

See all specifications

Highlights

  • Coil Power Consumption: Intermittent: 20-30W Continuous: 15-20W
  • Electrical Life: >100,000 cycles
  • Excellent Durability: Mechanical life >300,000 cycles, Electrical life >100,000 cycles
  • Fast Response: Contact jitter time <4ms
  • Low Contact Voltage Drop: <40mV @ 100A
  • Max Contact Voltage: 48V DC (No Blowout) / 96V DC (With Blowout)

Good to know before integrating

  • Thermal: rated operating range -40°C to +60°C — check it against the installation environment.
  • Thermal: rated operating range -40°C to +60°C — check it against the installation environment.