ZJWP400A
High-current DC contactor 400 A with magnetic blowout

- Operating Temperature
- -40°C to +60°C
- Wide Operating Temperature
- -40°C to +60°C
- Coil Power Consumption
- Intermittent: 30-40W Continuous: 15-30W
- Rated heating current
- 400A (100% Ith)
High-current DC contactor 400 A with magnetic blowout
HIITIO ZJWP400A low voltage DC contactor rated 400 A for switching heavy DC loads, up to 96 V DC with magnetic blowout.
Overview. The HIITIO ZJWP400A DC contactor, from the ZJWP series, is a low voltage contactor designed for switching high-current DC circuits. Its rated heating current is 400 A (100% Ith), and its maximum contact voltage is 48 V DC without blowout and 96 V DC with magnetic blowout.
Main characteristics. The contact voltage drop is below 40 mV at 100 A. Mechanical life exceeds 300,000 cycles and electrical life exceeds 100,000 cycles. Contact jitter time is below 4 ms for fast and stable switching. The unit weighs 1300 g and features strong terminals.
Coil power. Coil consumption is 30 to 40 W in intermittent operation and 15 to 30 W in continuous operation. Pick-up voltage is 60% Un intermittent and 66% Un continuous. Release voltage is 5 to 40% Un.
Environment. Operating temperature range is -40 °C to +60 °C, and storage temperature range is -40 °C to +85 °C.
Typical uses. This contactor suits large electric vehicles and commercial trucks, high-capacity solar and wind energy storage systems, advanced high-power battery management systems, industrial heavy machinery and DC power distribution, marine propulsion systems, and high-power charging stations and main disconnectors.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for ZJWP400A, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Coil Power Consumption | Intermittent: 30-40W Continuous: 15-30W |
| Electrical Life | >100,000 cycles |
| Fast & Stable Switching | Contact jitter time <4ms |
| Heavy-Duty Build | Weight 1300g with strong terminals |
| Low Contact Voltage Drop | <40mV @ 100A |
| Max Contact Voltage | 48V DC (No Blowout) / 96V DC (With Blowout) |
| Maximum Contact Voltage | 48V DC (No Blowout) / 96V DC (With Blowout) |
| Mechanical Life | >300,000 cycles |
| Model | ZJWP400A |
| Operating Temperature | -40°C to +60°C |
| Outstanding Lifespan | Mechanical >300,000 cycles, Electrical >100,000 cycles |
| Pick-up Voltage | Intermittent: 60% Un Continuous: 66% Un |
| Rated heating current | 400A (100% Ith) |
| Release Voltage | 5-40% Un |
| Storage Temperature | -40°C to +85°C |
| Weight | 1300g |
| Wide Operating Temperature | -40°C to +60°C |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for ZJWP400A. For a missing document or a specific revision, our experts send it to you.
HIITIO ZJWP400A low voltage DC contactor rated 400 A for switching heavy DC loads, up to 96 V DC with magnetic blowout.
| Parameter | Value |
|---|---|
| Coil Power Consumption | Intermittent: 30-40W Continuous: 15-30W |
| Electrical Life | >100,000 cycles |
| Fast & Stable Switching | Contact jitter time <4ms |
| Heavy-Duty Build | Weight 1300g with strong terminals |
| Low Contact Voltage Drop | <40mV @ 100A |
| Max Contact Voltage | 48V DC (No Blowout) / 96V DC (With Blowout) |
| Maximum Contact Voltage | 48V DC (No Blowout) / 96V DC (With Blowout) |
| Mechanical Life | >300,000 cycles |
| Model | ZJWP400A |
| Operating Temperature | -40°C to +60°C |
| Outstanding Lifespan | Mechanical >300,000 cycles, Electrical >100,000 cycles |
| Pick-up Voltage | Intermittent: 60% Un Continuous: 66% Un |
| Rated heating current | 400A (100% Ith) |
| Release Voltage | 5-40% Un |
| Storage Temperature | -40°C to +85°C |
| Weight | 1300g |
| Wide Operating Temperature | -40°C to +60°C |
Points to check before using ZJWP400A in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Coil Power Consumption | Intermittent: 30-40W Continuous: 15-30W |
| Low Contact Voltage Drop | <40mV @ 100A |
| Max Contact Voltage | 48V DC (No Blowout) / 96V DC (With Blowout) |
| Maximum Contact Voltage | 48V DC (No Blowout) / 96V DC (With Blowout) |
| Pick-up Voltage | Intermittent: 60% Un Continuous: 66% Un |
| Rated heating current | 400A (100% Ith) |
| Release Voltage | 5-40% Un |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of ZJWP400A can answer. A question is not asked when nothing is recorded to answer it.
-40°C to +60°C (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
High-current DC contactor 400 A with magnetic blowout

Low Voltage DC Contactor 150A 96V DC High Current Contactor with Magnetic Blowout

DC Contactor 200A 96V DC High Current Low Voltage Contactor

DC Contactor 125A 96V DC High Current Low Voltage Contactor with Magnetic Blowout

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | ZJWP400A |
| Manufacturer | HIITIO |
Power Contactors
1 Pole + Shunt 20A-40A Definite Purpose Contactor · Ref. : SA-1.5P
Price on request
Power Contactors
Three-pole power contactor 38 A AC-3 AC coil 50/60 Hz