The HIITIO ZJWP80A DC contactor switches direct currents up to 80 A, with magnetic blowout for contact voltages up to 96 V DC. It is used for DC load control and battery circuits.
Operating Temperature-40°C to +60°C
Wide Operating Temperature-40°C to +60°C
Coil Power ConsumptionIntermittent: 15-21W Continuous: 9-15W
Low Coil Power ConsumptionIntermittent 15-21W, Continuous 9-15W
Rated Current80A (100% Ith)
Rated heating current80A (100% Ith)
Product overview
HIITIO ZJWP80A. The HIITIO ZJWP80A is a low voltage DC contactor with magnetic blowout, designed to switch high-current direct currents up to 80 A.
Main characteristics. Rated current of 80 A (100% Ith) and rated heating current of 80 A. Maximum contact voltage of 48 V DC without blowout and 96 V DC with blowout. Contact voltage drop below 40 mV at 80 A. Contact jitter time below 4 ms for fast switching. Mechanical life above 300,000 cycles and electrical life above 100,000 cycles. Weight of 212 g.
Coil power and temperature range. Coil power consumption of 15 to 21 W intermittent and 9 to 15 W continuous. Pick-up voltage of 60% Un intermittent and 66% Un continuous. Release voltage of 5 to 40% Un. Operating temperature from -40 °C to +60 °C and storage temperature from -40 °C to +85 °C.
Typical uses. Electric vehicles, forklifts and golf carts, solar energy storage systems and BMS, battery chargers and pre-charge circuits, DC motor control and industrial automation, marine, RV and off-grid power solutions, agricultural equipment.
The HIITIO ZJWP80A DC contactor switches direct currents up to 80 A, with magnetic blowout for contact voltages up to 96 V DC. It is used for DC load control and battery circuits.
Operating Temperature-40°C to +60°C
Wide Operating Temperature-40°C to +60°C
Coil Power ConsumptionIntermittent: 15-21W Continuous: 9-15W
Low Coil Power ConsumptionIntermittent 15-21W, Continuous 9-15W
Points to check before using ZJWP80A in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -40°C to +60°C — check it against the installation environment.
2Thermalrated operating range -40°C to +60°C — check it against the installation environment.
Power and communication
Coil Power Consumption
Intermittent: 15-21W Continuous: 9-15W
Low Coil Power Consumption
Intermittent 15-21W, Continuous 9-15W
Low Contact Voltage Drop
<40mV @ 80A
Max Contact Voltage
48V DC (No Blowout) / 96V DC (With Blowout)
Maximum Contact Voltage
48V DC (No Blowout) / 96V DC (With Blowout)
Pick-up Voltage
Intermittent: 60% Un Continuous: 66% Un
Rated Current
80A (100% Ith)
Rated heating current
80A (100% Ith)
Release Voltage
5-40% Un
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -40°C to +60°C — check it against the installation environment.
Thermal : rated operating range -40°C to +60°C — check it against the installation environment.
Technical FAQ
Answers to the questions that the recorded characteristics of ZJWP80A can answer. A question is not asked when nothing is recorded to answer it.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productHIITIO
ZJWP80A
Low voltage DC contactor 80 A with magnetic blowout
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.