HK71
Monocrystalline Differential Pressure Transmitter 4-20 mA HART

- Pressure range
- ~100~16000KPa
- Alarm current default setting
- 21 mA
- Storage Temperature
- -40℃~120℃
- Accuracy
- 0.2%,0.075%,0.1%
Monocrystalline Differential Pressure Transmitter 4-20 mA HART
Industrial Pressure Transmitters (4-20mA / IO-Link)
The Holykell HK71 is a monocrystalline differential pressure transmitter with 4-20 mA output and HART protocol, designed for industrial pressure measurement.
Holykell HK71. monocrystalline differential pressure transmitter. The Holykell HK71 is a differential pressure transmitter with 4-20 mA output and HART protocol, with a pressure range of about 100 to 16000 kPa.
Performance. Accuracy is specified at 0.2%, 0.075% or 0.1% depending on the model. Stability is 0.1% over 3 years, and the influence of static pressure is less than or equal to ±0.04% URL per 10 °C. The amplifier damping constant is 0.1 s in high alarm mode.
Diagnostics and safety. If the sensor or circuit fails, the automatic diagnosis function outputs 3.9 mA or 21.0 mA. The default alarm current is 21 mA and can be preset by the user. The output can be linear or square root.
Power and environment. Power supply 12-36 V DC, 24 V DC recommended. Housing temperature range -20 °C to 70 °C for the LCD display and -40 °C to 80 °C for the OLED display. Medium temperature -40 °C to +120 °C and storage temperature -40 °C to 120 °C. LCD or OLED display.
Installation. Zero point and range can be adjusted to any value within the measurement limits. A change of installation position perpendicular to the diaphragm surface does not cause zero drift.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for HK71, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Pressure range | ~100~16000KPa |
| Response time | High alarm mode The damping constant of the amplifier component is 0.1s; the time constant of the |
| Accuracy | 0.2%,0.075%,0.1% |
| Alarm Current | If the sensor or circuit fails, the automatic diagnosis function will automatically output 3.9 or 21.0mA (user can pre-set) |
| Alarm current default setting | 21 mA |
| Ambient temperature | ±0.001%/10 V, which can be negligible |
| Ambient temperature influence | ±0.1%/3 years |
| Display | LCD,OLED |
| Fault warning | Imin=3.9mA, Imax=21.0mA |
| High report mode (maximum) | Low alarm mode (minimum): 3.9mA |
| Influence of installation location | range in the table, as long as: calibration range ≥ minimum range The change of the installation position perpendicular to the diaphragm surface will not cause the zero drift effect. If the installation position and the diaphragm surface change more than 90°, the zero position in the range of <0.4kPa will be affected. It can be adjusted by adjusting the zero and there is no impact on the |
| Influence of static pressure | ≤±0.04%URL/10℃ |
| IP Rating for Housing | -20℃~70℃ (LCD), -40℃~80℃ (OLED) |
| Medium temperature | -40°C~+120°C |
| Module temperature shown on display | LCD, OLED |
| Output | 4-20mA,Hart Protocol |
| Output signal limit | Linear or square root output is optional. |
| Power influence | 12-36 V DC(24 V DC recommended) |
| Power supply | 12-36 V DC |
| Range limit | Within the upper and lower limits of the measuring range, it can be adjusted |
| Stability | 0.1%/3 years |
| Storage Temperature | -40℃~120℃ |
| Zero point setting | arbitrarily. It is recommended to select a range code with the lowest possible turndown ratio to optimize performance Zero point and range can be adjusted to any value within the measurement |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for HK71. For a missing document or a specific revision, our experts send it to you.
The Holykell HK71 is a monocrystalline differential pressure transmitter with 4-20 mA output and HART protocol, designed for industrial pressure measurement.
| Parameter | Value |
|---|---|
| Pressure range | ~100~16000KPa |
| Response time | High alarm mode The damping constant of the amplifier component is 0.1s; the time constant of the |
| Accuracy | 0.2%,0.075%,0.1% |
| Alarm Current | If the sensor or circuit fails, the automatic diagnosis function will automatically output 3.9 or 21.0mA (user can pre-set) |
| Alarm current default setting | 21 mA |
| Ambient temperature | ±0.001%/10 V, which can be negligible |
| Ambient temperature influence | ±0.1%/3 years |
| Display | LCD,OLED |
| Fault warning | Imin=3.9mA, Imax=21.0mA |
| High report mode (maximum) | Low alarm mode (minimum): 3.9mA |
| Influence of installation location | range in the table, as long as: calibration range ≥ minimum range The change of the installation position perpendicular to the diaphragm surface will not cause the zero drift effect. If the installation position and the diaphragm surface change more than 90°, the zero position in the range of <0.4kPa will be affected. It can be adjusted by adjusting the zero and there is no impact on the |
| Influence of static pressure | ≤±0.04%URL/10℃ |
| IP Rating for Housing | -20℃~70℃ (LCD), -40℃~80℃ (OLED) |
| Medium temperature | -40°C~+120°C |
| Module temperature shown on display | LCD, OLED |
| Output | 4-20mA,Hart Protocol |
| Output signal limit | Linear or square root output is optional. |
| Power influence | 12-36 V DC(24 V DC recommended) |
| Power supply | 12-36 V DC |
| Range limit | Within the upper and lower limits of the measuring range, it can be adjusted |
| Stability | 0.1%/3 years |
| Storage Temperature | -40℃~120℃ |
| Zero point setting | arbitrarily. It is recommended to select a range code with the lowest possible turndown ratio to optimize performance Zero point and range can be adjusted to any value within the measurement |
Answers to the questions that the recorded characteristics of HK71 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Alarm Current": If the sensor or circuit fails, the automatic diagnosis function will automatically output 3.9 or 21.0mA (user can pre-set).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Monocrystalline Differential Pressure Transmitter 4-20 mA HART

Smart Capacitance Differential Pressure Transmitter

SUP-P300 Pressure transmitter with compact size for universal use

SUP-P350K Hygienic pressure transmitter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | HK71 |
| Manufacturer | Holykell |
Industrial Pressure Transmitters (4-20mA / IO-Link)
ATEX pressure transmitter with flush diaphragm · Ref. : MPM489
Price on request
Industrial Pressure Transmitters (4-20mA / IO-Link)
Monocrystal Silicon Differential Pressure Transmitter 4-20mA · Ref. : HPT708
Price on request
Industrial Pressure Transmitters (4-20mA / IO-Link)
Gauge Pressure Transmitter for Industrial Process
Price on request
Industrial Pressure Transmitters (4-20mA / IO-Link)
Industrial pressure transmitter 4-20 mA HART RS485 Modbus · Ref. : 35723348-00
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details