HK75 – Smart capacitance differential pressure transmitter 4-20 mA HART

Smart capacitance differential pressure transmitter 4-20 mA HART

Industrial Pressure Transmitters (4-20mA / IO-Link)

  • 21 mA
  • -40℃ ~105℃
  • -40℃ ~85℃
  • ≤±0.04%URL/10℃
Manufacturer part number
HK75
Manufacturer
Holykell
Storage Temperature
-40℃ ~105℃
Ambient temperature
-40℃ ~85℃

Holykell HK75 differential pressure transmitter with monocrystalline silicon sensor for measuring gas, steam and liquids, with 4-20 mA output and superimposed HART digital signal.

Product overview

Overview. The Holykell HK75 differential pressure transmitter is a smart capacitance transmitter fitted with a monocrystalline silicon pressure sensor. It measures differential pressure in gases, steam and liquids, and can also be used for level, volume or mass measurements in liquids.

Accuracy and stability. Accuracy is ±0.2%, ±0.075% or ±0.1% (including linearity, hysteresis and repeatability from zero). Stability is ±0.1% over 3 years. Ambient temperature influence is ≤±0.04% URL/10°C and static pressure influence is ±0.05%/10 MPa.

Output and communication. Two-wire 4-20 mA output in line with the NAMUR NE43 specification, with a superimposed digital signal using the HART protocol. The output can be linear or square root. In case of sensor or circuit failure, the automatic diagnosis outputs 3.9 mA or 21.0 mA, the value being presettable by the user (21 mA by default).

Power and environment. Power supply 12-36 V DC (24 V DC recommended). Ambient temperature -40°C to 85°C, measuring medium temperature -40°C to 120°C, storage temperature -40°C to 105°C. Housing rated IP67. LCD or OLED display.

Typical uses. Differential pressure measurement on gas and steam, level, volume or mass measurement on liquids, in process control and monitoring installations, integrated into a 4-20 mA loop or a HART network.

Integration. Measuring range and zero point can be set to any value within the measurement range; selecting the range code with the lowest possible turndown ratio is recommended to optimise performance. A change in installation position perpendicular to the diaphragm surface does not cause zero drift.

Note. Pressure ranges, process connections and other options are defined by the configuration requested on quotation.

See all specifications

Highlights

  • Alarm current default setting: 21 mA
  • Ambient temperature: -40℃ ~85℃
  • Ambient temperature influence: ≤±0.04%URL/10℃
  • Display: LCD, OLED
  • Fault warning: Imin=3.9mA, Imax=21.0mA
  • High report mode (maximum): Low alarm mode (minimum): 3.9mA