Submersible data logger for monitoring groundwater or surface water level, pressure and temperature, powered by a lithium battery or external supply.
Operating Temperature-10~80℃
Pressure range0~10m H₂O…300m H₂O
Measuring Range0~10 m H₂O…300 m H₂O
Temp. compensation range0~50℃
Real-time clock<±5 min/year
model; parameterHPT675S
Product overview
Overview. The HPT675S remote water level data logger from Holykell is a self-powered logger for monitoring the depth, pressure and temperature of groundwater or surface water. Its titanium alloy or 316L shell and IP68 rating allow prolonged immersion.
Main characteristics. Measuring range from 0 to 10 m H₂O up to 300 m H₂O, level accuracy of 0.05 % F.S (0 to 50 °C), level resolution of 1 mm, temperature accuracy of ±0.2 °C with 0.1 °C resolution, and stability of 0.05 % F.S per year. Overload tolerance of 200 % F.S. Built-in 128 M memory can record 1,000,000 data points (time, temperature, pressure and water level).
Power and environment. External supply DC 5 to 30 V (typically 24 V) or internal battery 2.7 to 3.6 V DC, with a battery life of 10 years at one reading every 60 minutes. Protection against reverse connection and against 2 kV surge and overvoltage. Operating temperature -10 to 80 °C, temperature compensation range 0 to 50 °C. Complies with GB/T 9359 (vibration and free fall) and GB/T 17626.8 Level 3 (electromagnetic environment). Mean time between failures not less than 30,000 h.
Interfaces and connectivity. RS485 output with MODBUS-RTU protocol, usable in a DCS or PLC system. Data is downloaded to a computer via an RS485 to USB adapter. Wiring: red 5 V+, yellow GND, blue RS485+, green RS485-.
Typical uses. Monitoring of groundwater and surface water levels, marine environmental engineering projects, flood control and flood level monitoring, real-time tank level monitoring and integration into industrial control systems.
Integration. Cable material is PVC or polyurethane. Wetted parts are compatible with 316L stainless steel and fluororubber.
Compatible with 316L stainless steel and fluororubber
Measuring Range
0~10 m H₂O…300 m H₂O
Memory Capacity
128M built-in storage, can record 1,000,000 data (time + temperature + pressure + water level)
model; parameter
HPT675S
Operating Temperature
-10~80℃
Output
RS485 to USB. Download data to computer via adapter
Overload
200% F.S
Power Protection
Protection against reverse connection,and against 2KV surge and over voltage
Protection Class
IP68
Protection Grade
IP68
Real-time clock
<±5 min/year
RED
5V+
Sensitive Element:
High stability, low drift in long term use
Shell material
Titanium alloy/316L
Stability
0.05%F.S/year
Temp. compensation range
0~50℃
Temp. resolution
0.1℃
Yellow
GND
Integration
Points to check before using HPT675S in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -10~80℃ — check it against the installation environment.
Protection against reverse connection,and against 2KV surge and over voltage
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -10~80℃ — check it against the installation environment.
Applications and use cases
Architectures in which HPT675S can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
A fridge that drifts at night can ruin a whole stock. Temperature loggers in cold rooms and trucks report through a gateway or a tracker and raise an alert when a threshold is crossed
To check
Temperature range and accuracy required by the product
Record keeping required by the applicable regulations
Alert thresholds and who is notified
Associated system blocks
Temperature loggersTransport trackingGateway
Need a complete solution?
Send a request for HPT675S and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.