MacSync LX1 – Industrial RS485 Modbus to LoRaWAN converter

Industrial RS485 Modbus to LoRaWAN converter

Cold Chain Monitors

  • Up to 115,200 bps
  • Reporting
  • Example payload
  • Notes
Manufacturer part number
RS485-TO-LORAWAN-CONVERTER-MACSYNC-STD
Manufacturer
Macnman
Baud rate
Up to 115,200 bps
Outputs
None: it reads and reports

Industrial Macnman converter acting as Modbus RTU master on RS485, polling meters, drives or PLCs and carrying their registers over LoRaWAN®.

Product overview

Overview. The Macnman MacSync LX1 is an industrial Modbus RTU to LoRaWAN® converter. It acts as Modbus RTU master on an RS485 line, polling existing slaves such as energy meters, flow meters, drives and PLCs, and carrying their registers over LoRaWAN®. The slave devices are not modified. Main characteristics — It reads and writes registers with function codes 03, 04, 06 and 16. Writes, polled registers, baud rate and parity can be changed by downlink. Serial baud rate ranges from 1,200 to 115,200 bps. Interfaces and connectivity — One RS485 port, half-duplex, with Modbus RTU support. The LoRaWAN® v1.0.4 link runs in Class A or C at 23 dBm, in bands from IN865 to AU915. A range of about 2 km across a built-up site and up to 8 km line of sight is stated. An analog mode turns the terminals into two 4–20 mA, 0–10 V or digital channels. Power and environment — Powered by a field replaceable 19 Ah battery or 9–36 V DC. IP65 enclosure, IP67 optional, operating from −40 to +80 °C. The product is WPC compliant. Typical uses — Remote reading of meters and drives spread over a site, with or without mains power. Integration — One slave ID per device on the bus, with 16-bit or 32-bit registers (INT16, UINT16, INT32, FLOAT32) according to the equipment's Modbus map.

See all specifications

Highlights

  • Baud rate: Up to 115,200 bps
  • Baud rate — 1,200 to 115,200 bps: All slaves on the bus must use the same rate
  • Configuration: AT commands · downlink · RS485-LB adds Bluetooth
  • Data types — INT16 · UINT16 · INT32 · FLOAT32: 32-bit values with the most or the least significant word first
  • Device — What it reads — Typical setup: Reporting
  • Devices and reads: RS485-LN: up to 32 RS485 devices · 15 commands per sampling