UEC2-12
3-pole AC contactor 12 A, 24 to 380 V coil

- Hold-in Power Consumption in VA
- 14 VA 50/60 Hz (at 25 °C)
- Minimum Switching Current
- 5mA for signalling circuit
- Mounting Support
- Screw; 35mm DIN Rail
- Number of Units in Package 1
- /
3-pole AC contactor 12 A, 24 to 380 V coil
The Hongfa UEC2-12 is a 3-pole (3 NO) AC contactor for switching power loads up to 690 V, mountable on 35 mm DIN rail or by screw.
Hongfa UEC2-12 contactor. The UEC2-12 is a 3-pole (3P, 3 NO) AC contactor from the Hongfa UEC2 series, intended for switching power and signalling circuits.
Main characteristics. Rated operational current of 12 A in AC-3 at 400 V and 32 A in AC-1 at 690 V, conventional free air thermal current of 32 A, rated operational voltage up to 690 V AC 50/60 Hz, rated impulse withstand voltage of 6 kV. Auxiliary contact composition 1 NO + 1 NC for the signalling circuit, with an associated 10 A gG fuse.
Motor power. 3 kW at 220/230 V AC, 5.5 kW at 380/400 V AC and 7.5 kW at 660/690 V AC (AC-3).
Control circuit. AC coil at 50/60 Hz for control voltages of 24, 220 or 380 V, operational limits 0.85 to 1.1 Us and drop-out limits 0.2 to 0.75 Us, from -40 to 85 °C. Inrush power of 130 VA and hold-in power of 14 VA at 25 °C, without built-in suppressor module.
Durability and operation. Mechanical durability of 5.0 million cycles, electrical durability of 0.2 million cycles at Ue ≤ 400 V according to ARI 780/790, maximum operating rate of 1200 cycles/h electrical and 3600 cycles/h mechanical. Closing time of 12 to 22 ms and opening time of 5 to 19 ms for the power circuit.
Connection and mounting. Screw clamp terminals, tightening torque of 1.7 to 2.0 N·m for the power circuit and 0.8 to 1.2 N·m for the control circuit. Mounting by screw or on 35 mm DIN rail. IP20 front face protection, dimensions 45 × 81 × 86.5 mm, net weight 0.42 kg.
Environment and compliance. Ambient operating temperature from -40 to 85 °C, operating altitude up to 3000 m without derating, overvoltage category III, fire resistance of 850 °C according to IEC 60695-2-11. Compliant with IEC/EN 60947-4-1 and IEC/EN 60947-5-1 standards and with CCC, CE and UKCA certifications, RoHS and REACh conforming, mercury free.
Use. Switching of motors and resistive loads in industrial electrical installations. To receive a quotation, contact Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for UEC2-12, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1; 32 A gG at ≤ 690 V coordination type 2 for power circuit |
| Auxiliary Contact Composition | 1NO,1NC |
| Average Impedance | 2.4 mΩ - Ith 50 Hz for power circuit |
| China RoHS Regulation | Conforming |
| Coil Technology | Without built-in suppressor module |
| Control Circuit Type | AC at 50/60 Hz standard |
| Control Circuit Voltage Limits | 0.85...1.1 Us (-40…85 °C): operational AC 50/60 Hz; 0.2...0.75 Us (-40…85 °C): drop-out AC 50/60 Hz |
| Depth | 86.5 mm |
| Device Short Name | UEC2-12C |
| Electrical Durability | 0.2 M cycles at Ue ≤ 400 V conforming to ARI 780/790 |
| EU RoHS Directive | Conforming |
| Fire Resistance | Current-carrying parts:850 °C conforming to IEC 60695-2-11 |
| Height | 81 mm |
| Hold-in Power Consumption in VA | 14 VA 50/60 Hz (at 25 °C) |
| [Ie] Rated Operational Current | 12 A (at ≤85 °C) at ≤ 400 V AC AC-3 for power circuit; 32 A (at ≤85 °C) at ≤ 690 V AC AC-1 for power circuit |
| Inrush Power in VA | 130 VA 50/60 Hz (at 25 °C) |
| Insulation Resistance | > 10 MΩ for signalling circuit |
| IP Degree of Protection | IP20 front face conforming to IEC 60529 |
| [Ith] Conventional Free Air Thermal Current | 32 A (at ≤85 °C) for power circuit; 10 A (at ≤85 °C) for signalling circuit |
| Maximum Operating Rate | Electrical: 1200 cycs/h; Mechanical: 3600 cycs/h |
| Mechanical Durability | 5.0 M cycles |
| Mechanical Robustness | Vibrations: 40m/s2, 5Hz ~ 60Hz; Shocks: 80m/s2 for 11ms of half sine wave with contactor open; Shocks: 150m/s2 for 11ms of half sine wave with contactor closed |
| Mercury Free | Yes |
| Minimum Switching Current | 5mA for signalling circuit |
| Minimum Switching Voltage | 17 V for signalling circuit |
| Motor Power kW | 3 kW at 220/230 V AC 50/60 Hz (AC-3); 5.5 kW at 380/400 V AC 50/60 Hz (AC-3); 7.5 kW at 660/690 V AC 50/60 Hz (AC-3) |
| Mounting Support | Screw; 35mm DIN Rail |
| Net weight | 0.42 kg |
| Number of Units in Package 1 | / |
| Number of Units in Package 2 | 20 pcs |
| Operating Altitude | 0...3000 m without derating |
| Operating Time | Power circuit: 12...22 ms closing, 5...19 ms opening; Signalling circuit (NO): 12...25 ms closing, 9...17 ms opening; Signalling circuit (NC): 9...17 ms opening, 10...25 ms closing |
| Overvoltage category | III |
| Package 1 Height | / |
| Package 1 Length | / |
| Package 1 Weight | / |
| Package 1 Width | / |
| Package 2 Height | 21.5 cm |
| Package 2 Length | 25.3 cm |
| Package 2 Weight | 8.8 kg |
| Package 2 Width | 18.9 cm |
| Permissible Ambient Air; Temperature Around the Device | -40…85 °C for normal operating; Storage: -55…85 °C |
| Pole Contact Composition | 3 NO |
| Poles Description | 3P |
| Product Certifications | CCC,CE,UKCA |
| Product or Component Type | Contactor |
| Product Series | UEC2 |
| REACh Regulation | Conforming |
| RoHS Exemption Information | Yes |
| Standards | GB/T 14048.4,GB/T 14048.5, IEC/EN 60947-4-1,IEC/EN 60947-5-1,; BS EN 60947-4-1,BS EN 60947-5-1 |
| Tightening torque | Power circuit: (15~18) lb.in (1.7~2.0 N·m)- on screw clamp terminals - with screwdriver flat Ø 6 mm; Power circuit: (15~18) lb.in (1.7~2.0 N·m) - on screw clamp terminals - with screwdriver Philips (POZI) No 2; Control circuit: (7~10.7) lb.in (0.8~1.2 N·m) - on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: (7~10.7) lb.in (0.8~1.2 N·m) - on screw clamp terminals - with screwdriver Philips (POZI) No 2 |
| [Ue]Rated Operational Voltage | Power circuit: ≤ 690 V AC 50/60Hz |
| [Ui] Rated Insulation Voltage | Power circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-5-1 |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to IEC 60947 |
| Unit Type of Package 1 | / |
| Unit Type of Package 2 | 1 carton |
| [Us] Control Circuit Voltage; (AC 50/60Hz) | Voltage (V): 24 220 380 |
| Utilisation Category | AC-3; AC-1 |
| Width | 45 mm |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for UEC2-12. For a missing document or a specific revision, our experts send it to you.
The Hongfa UEC2-12 is a 3-pole (3 NO) AC contactor for switching power loads up to 690 V, mountable on 35 mm DIN rail or by screw.
| Parameter | Value |
|---|---|
| Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1; 32 A gG at ≤ 690 V coordination type 2 for power circuit |
| Auxiliary Contact Composition | 1NO,1NC |
| Average Impedance | 2.4 mΩ - Ith 50 Hz for power circuit |
| China RoHS Regulation | Conforming |
| Coil Technology | Without built-in suppressor module |
| Control Circuit Type | AC at 50/60 Hz standard |
| Control Circuit Voltage Limits | 0.85...1.1 Us (-40…85 °C): operational AC 50/60 Hz; 0.2...0.75 Us (-40…85 °C): drop-out AC 50/60 Hz |
| Depth | 86.5 mm |
| Device Short Name | UEC2-12C |
| Electrical Durability | 0.2 M cycles at Ue ≤ 400 V conforming to ARI 780/790 |
| EU RoHS Directive | Conforming |
| Fire Resistance | Current-carrying parts:850 °C conforming to IEC 60695-2-11 |
| Height | 81 mm |
| Hold-in Power Consumption in VA | 14 VA 50/60 Hz (at 25 °C) |
| [Ie] Rated Operational Current | 12 A (at ≤85 °C) at ≤ 400 V AC AC-3 for power circuit; 32 A (at ≤85 °C) at ≤ 690 V AC AC-1 for power circuit |
| Inrush Power in VA | 130 VA 50/60 Hz (at 25 °C) |
| Insulation Resistance | > 10 MΩ for signalling circuit |
| IP Degree of Protection | IP20 front face conforming to IEC 60529 |
| [Ith] Conventional Free Air Thermal Current | 32 A (at ≤85 °C) for power circuit; 10 A (at ≤85 °C) for signalling circuit |
| Maximum Operating Rate | Electrical: 1200 cycs/h; Mechanical: 3600 cycs/h |
| Mechanical Durability | 5.0 M cycles |
| Mechanical Robustness | Vibrations: 40m/s2, 5Hz ~ 60Hz; Shocks: 80m/s2 for 11ms of half sine wave with contactor open; Shocks: 150m/s2 for 11ms of half sine wave with contactor closed |
| Mercury Free | Yes |
| Minimum Switching Current | 5mA for signalling circuit |
| Minimum Switching Voltage | 17 V for signalling circuit |
| Motor Power kW | 3 kW at 220/230 V AC 50/60 Hz (AC-3); 5.5 kW at 380/400 V AC 50/60 Hz (AC-3); 7.5 kW at 660/690 V AC 50/60 Hz (AC-3) |
| Mounting Support | Screw; 35mm DIN Rail |
| Net weight | 0.42 kg |
| Number of Units in Package 1 | / |
| Number of Units in Package 2 | 20 pcs |
| Operating Altitude | 0...3000 m without derating |
| Operating Time | Power circuit: 12...22 ms closing, 5...19 ms opening; Signalling circuit (NO): 12...25 ms closing, 9...17 ms opening; Signalling circuit (NC): 9...17 ms opening, 10...25 ms closing |
| Overvoltage category | III |
| Package 1 Height | / |
| Package 1 Length | / |
| Package 1 Weight | / |
| Package 1 Width | / |
| Package 2 Height | 21.5 cm |
| Package 2 Length | 25.3 cm |
| Package 2 Weight | 8.8 kg |
| Package 2 Width | 18.9 cm |
| Permissible Ambient Air; Temperature Around the Device | -40…85 °C for normal operating; Storage: -55…85 °C |
| Pole Contact Composition | 3 NO |
| Poles Description | 3P |
| Product Certifications | CCC,CE,UKCA |
| Product or Component Type | Contactor |
| Product Series | UEC2 |
| REACh Regulation | Conforming |
| RoHS Exemption Information | Yes |
| Standards | GB/T 14048.4,GB/T 14048.5, IEC/EN 60947-4-1,IEC/EN 60947-5-1,; BS EN 60947-4-1,BS EN 60947-5-1 |
| Tightening torque | Power circuit: (15~18) lb.in (1.7~2.0 N·m)- on screw clamp terminals - with screwdriver flat Ø 6 mm; Power circuit: (15~18) lb.in (1.7~2.0 N·m) - on screw clamp terminals - with screwdriver Philips (POZI) No 2; Control circuit: (7~10.7) lb.in (0.8~1.2 N·m) - on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: (7~10.7) lb.in (0.8~1.2 N·m) - on screw clamp terminals - with screwdriver Philips (POZI) No 2 |
| [Ue]Rated Operational Voltage | Power circuit: ≤ 690 V AC 50/60Hz |
| [Ui] Rated Insulation Voltage | Power circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-5-1 |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to IEC 60947 |
| Unit Type of Package 1 | / |
| Unit Type of Package 2 | 1 carton |
| [Us] Control Circuit Voltage; (AC 50/60Hz) | Voltage (V): 24 220 380 |
| Utilisation Category | AC-3; AC-1 |
| Width | 45 mm |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
3-pole AC contactor 12 A, 24 to 380 V coil




Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | UEC2-12 |
| Manufacturer | Hongfa |
Power Contactors
1 Pole + Shunt 20A-40A Definite Purpose Contactor · Ref. : SA-1.5P
Price on request
Power Contactors
Three-pole power contactor 38 A AC-3 AC coil 50/60 Hz
Price on request
Power Contactors
Technical article: relay versus contactor differences
Price on request
Power Contactors
EPS box with integrated contactors for 1-phase/3-phase inverters · Ref. : X1/X3-EPS
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details