3-pole molded case circuit breaker 100 A

Molded Case Circuit Breakers

  • UEM5Z1
  • 100 A at 40 °C
  • 50 Hz
  • -40…70 °C
Manufacturer part number
UEM5Z1-100
Manufacturer
Hongfa
Range
UEM5Z1
Rated Current (In)
100 A at 40 °C

Hongfa UEM5Z1-100 molded case circuit breaker with LSIP thermal-magnetic trip unit, 100 A rating, for distribution protection on 400 V AC 50 Hz networks.

Product overview

Hongfa UEM5Z1-100. Molded case circuit breaker (MCCB) from the UEM5Z1 series, with thermal-magnetic trip unit, designed for distribution protection on 400 V AC 50 Hz networks, with a rated current of 100 A at 40 °C in a 3-pole version.

Protection. LSIP trip unit combining adjustable long-time overload protection (Ir adjustable from 40 A to 100 A, tr from 12 s to 100 s or OFF), adjustable short-time short-circuit protection (Isd from 2 to 12 xIr or OFF, tsd from 0.06 s to 0.3 s), adjustable instantaneous short-circuit protection (Ii from 3 to 12 xIn or OFF) and pre-alarm protection (Ip from 0.7 to 1.0 xIr).

Breaking capacity. Rated service short-circuit breaking capacity Ics of 50 kA at 400 V AC 50 Hz conforming to IEC 60947-2, M version; rated ultimate short-circuit breaking capacity Icu of 50 kA (M version) or 70 kA (H version) at 400 V AC 50 Hz conforming to IEC 60947-2, with rated insulation voltage Ui of 800 V AC 50 Hz and rated impulse withstand voltage Uimp of 8 kV.

Accessories and connection. Compatible with shunt release, undervoltage release, auxiliary contacts, alarm contact and motorized or rotary operating mechanisms; fixed or plug-in mounting, 30 mm connection pitch.

Environment and durability. Operation from -25 to 70 °C, storage from -40 to 70 °C, relative humidity 0 to 95 % (25 °C), operating altitude up to 2000 m without derating, pollution degree 3 conforming to IEC 60664-1; mechanical durability of 8500 cycles and electrical durability of 1500 cycles at 400 V In.

Applications. Distribution circuit breaker in utilisation category A, conforming to EN/IEC 60947, suitable for isolation conforming to EN/IEC 60947-2; CCC and CB certifications. Available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Ambient Air Temperature for Operation: -25…70 °C
  • Ambient Air Temperature for Storage: -40…70 °C
  • Arcing Distance (mm): ≤50mm
  • Breaking Capacity: M、H
  • Connection Pitch: 30 mm
  • Depth: 78 mm

See also

Technical questions

Ask a question