UEM5L-100 – 100 A molded case earth leakage circuit breaker 3P/4P

100 A molded case earth leakage circuit breaker 3P/4P

Molded Case Circuit Breakers

  • UEM5L
  • 50 Hz
  • -40…70 °C
  • Fixed; Plug-in type
Manufacturer part number
UEM5L-100
Manufacturer
Hongfa
Range
UEM5L
Network Frequency
50 Hz

The Hongfa UEM5L-100 is a molded case earth leakage circuit breaker for 400 V AC distribution, rated 100 A, with adjustable earth leakage protection and a breaking capacity of 35 to 70 kA.

Product overview

Hongfa UEM5L-100 earth leakage circuit breaker — The Hongfa UEM5L-100 is a molded case earth leakage circuit breaker from the UEM5L series, listed among molded case circuit breakers, intended for AC electrical distribution. It is designed for an operational voltage of 400 V AC 50 Hz and a rated current of 100 A at 40 °C.

Main characteristics. The product combines thermal-magnetic trip technology with adjustable earth leakage protection. The earth leakage sensitivity adjustment is 30, 100, 300 or 500 mA for the non-time delay type, and 100, 300 or 500 mA for the time delay type. The instantaneous protection pick-up adjustment is 10 In for power distribution and 12 In for motor protection. It is offered in 3P or 4P versions, with utilisation category A and suitability for isolation conforming to IEC 60947-2.

Breaking capacity. The rated service short-circuit breaking capacity Ics is 35 kA for the M version and 50 kA for the H version, at 400 V AC 50 Hz conforming to IEC 60947-2. The rated ultimate short-circuit breaking capacity Icu is 50 kA for the M version and 70 kA for the H version.

Control and accessories. The breaker can be operated by handle, by motorized operating mechanism or by rotary operating mechanism. It accepts electrical accessories: alarm contact, shunt release, auxiliary contact and undervoltage release. It is compatible with the motorized operating mechanisms CD2 and CD2B and with the manual operating mechanisms SC1-F and SC1-Y. Mechanical durability is 8500 cycles and electrical durability is 1500 cycles at 400 V In.

Environment and installation. The ambient air temperature for operation is -25 to 70 °C and for storage -40 to 70 °C. Relative humidity is 0 to 95 % at 25 °C. Pollution degree is 3 conforming to IEC 60664-1, rated impulse withstand voltage is 8 kV and rated insulation voltage is 800 V AC 50 Hz. Mounting can be fixed or plug-in, with a connection pitch of 30 mm. Dimensions are 155 mm high and 76 mm deep, with a width of 90 mm for 3P and 120 mm for 4P. The product is certified CCC and CB.

See all specifications

Highlights

  • Ambient Air Temperature for Operation: -25…70 °C
  • Ambient Air Temperature for Storage: -40…70 °C
  • Arcing Distance (mm): ≤50mm
  • Breaking Capacity: M、H
  • Connection Pitch: 30 mm
  • Depth: 76mm

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote