UEM5L-250 – Earth leakage MCCB 250 A 400 V AC

Earth leakage MCCB 250 A 400 V AC

Molded Case Circuit Breakers

  • UEM5L
  • 50 Hz
  • -40…70 °C
  • Fixed; Plug-in type
Manufacturer part number
UEM5L-250
Manufacturer
Hongfa
Range
UEM5L
Network Frequency
50 Hz

The Hongfa UEM5L-250 is an earth leakage molded case circuit breaker rated 250 A for protection and distribution of power in 400 V AC networks.

Product overview

Earth leakage protection. The Hongfa UEM5L-250 is an earth leakage molded case circuit breaker (MCCB) from the UEM5L range, designed for power distribution on 50 Hz AC networks. It is offered with a rated current of 250 A at 40 °C, in 3-pole or 4-pole versions.

Main characteristics. Rated operational voltage of 400 V AC and rated insulation voltage of 800 V AC. Rated ultimate short-circuit breaking capacity Icu of 50 kA (M version) or 70 kA (H version) at 400 V AC, conforming to IEC 60947-2. Rated impulse withstand voltage of 8 kV. Thermal-magnetic trip unit with instantaneous pick-up adjustable to 10 In for power distribution or 12 In for motor protection.

Earth leakage protection. Sensitivity adjustable from 30 to 500 mA depending on the version, with selectable time delay or non-time delay operation. Earth-leakage protection class AC or A depending on the model.

Accessories and control. Operated by handle, by motorized operating mechanism or by rotary operating mechanism. Electrical accessories available: auxiliary contact, alarm contact, shunt release and undervoltage release. Fixed or plug-in mounting, with a connection pitch of 35 mm.

Operating conditions. Ambient air temperature for operation from -25 to 70 °C, storage temperature from -40 to 70 °C, relative humidity 0 to 95 % at 25 °C, operating altitude 0 to 2000 m without derating, pollution degree 3. Mechanical durability of 7000 cycles and electrical durability of 1000 cycles at 400 V In.

Typical uses. Protection and isolation of distribution feeders in three-phase or four-pole 400 V AC installations, provided that IEC 60947-2 and the operating conditions are met. Three-pole versions are not recommended for residual current protection and are reserved for cases without neutral conductor or dedicated earthing.

See all specifications

Highlights

  • Ambient Air Temperature for Operation: -25…70 °C
  • Ambient Air Temperature for Storage: -40…70 °C
  • Arcing Distance (mm): ≤50mm
  • Breaking Capacity: M、H
  • Connection Pitch: 35 mm
  • Depth: 85mm

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote