UEM5Z1-160
3-pole molded case circuit breaker 160 A 50 kA

- Range
- UEM5Z1
- Rated Current (In)
- 160 A at 40 °C
- Network Frequency
- 50 Hz
- Ambient Air Temperature for Storage
- -40…70 °C
3-pole molded case circuit breaker 160 A 50 kA
Hongfa 3-pole 160 A molded case circuit breaker for distribution protection on 400 V AC 50 Hz networks, with LSIP thermal-magnetic trip unit.
Hongfa UEM5Z1-160. The UEM5Z1-160 is a 3-pole (3P) molded case circuit breaker (MCCB) from the UEM5Z1 series, intended for distribution on 400 V AC 50 Hz alternating current networks.
Protection. LSIP thermal-magnetic trip unit providing overload long-time delay protection, short-circuit short-time delay protection, short-circuit instantaneous protection and pre-alarm protection. Rated current of 160 A at 40 °C, long-time pick-up Ir adjustable at 100 A, 125 A, 140 A or 160 A, short-time pick-up Isd adjustable from 2 to 12 xIr or OFF, instantaneous pick-up Ii adjustable from 3 to 12 xIn or OFF.
Breaking capacity. Rated service short-circuit breaking capacity Ics of 50 kA at 400 V AC 50 Hz conforming to IEC 60947-2, rated ultimate short-circuit breaking capacity Icu of 50 kA (M version) or 70 kA (H version) at 400 V AC 50 Hz conforming to IEC 60947-2, utilisation category A, suitable for isolation conforming to EN/IEC 60947-2.
Voltage and environment. Rated insulation voltage Ui of 800 V AC 50 Hz, rated impulse withstand voltage Uimp of 8 kV, pollution degree 3 conforming to IEC 60664-1, operating altitude 0 to 2000 m without derating and 2000 m to 4000 m with derating, ambient operating air temperature -25 to 70 °C, relative humidity 0 to 95 % at 25 °C.
Mounting and dimensions. Fixed or plug-in mounting, connection pitch 30 mm, height 155 mm, depth 78 mm, width 90 mm for 3P. Mechanical durability of 7000 cycles and electrical durability of 1000 cycles at 400 V In.
Accessories. Compatible with shunt release, undervoltage release, auxiliary contacts, alarm contact and motorized or rotary operating mechanisms, as listed in the manufacturer documentation.
Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for UEM5Z1-160, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Ambient Air Temperature for Operation | -25…70 °C |
| Ambient Air Temperature for Storage | -40…70 °C |
| Arcing Distance (mm) | ≤50mm |
| Breaking Capacity | M、H |
| China RoHS Regulation | China RoHS declaration; Product out of China RoHS scope. Substance declaration for your information. |
| Circuit Breaker Mounting Mode | Fixed; Plug-in type |
| Connection Pitch | 30 mm |
| Control type | Operated by handle; Operated by motorized operating mechanism; Operated by rotary operating mechanism |
| Depth | 78 mm |
| Device Application | Distribution |
| Device Short Name | UEM5Z1-160 |
| Electrical Accessory Types | Alarm contact; Shunt release; Auxiliary contact; Undervoltage release |
| Electrical Durability | 1000 cycles at 400 V In |
| Height | 155 mm |
| Instantaneous Protection; Pick-up Adjustment Range [Ii] | (3、4、5、6、7、8、9、10、12) xIn、OFF |
| Instantaneous Protection Pickup Adjustment Type Ii | Adjustable |
| Long-Time Pick-up Adjustment; Type Ir (thermal protection) | Adjustable |
| Long-Time Protection Delay; Adjustment Range [tr] | 12s、60s、80s、100s、OFF |
| Long-Time Protection Delay; Adjustment Type tr | Adjustable |
| Long-Time Protection Pick-up; Adjustment Range [Ir] | 100A、125A、140A、160A |
| Mechanical Durability | 7000 cycles |
| Mounting Position | Horizontal and vertical flat on the back |
| Net weight | 1.6kg(3P)/2.5 kg(4P) |
| Network Frequency | 50 Hz |
| Network type | AC |
| Operating Altitude | 0...2000 m without derating; 2000 m...4000 m with derating |
| Package — 3P | 4P |
| Package Height 1 | 15.6cm |
| Package Height 2 | 33.3cm |
| Package Length 1 — 20.1cm | 20.2cm |
| Package Length 2 — 41.5cm | 41.7cm |
| Package Weight 1 — 1.95kg | 2.89kg |
| Package Weight 2 — 15.6kg | 23kg |
| Package Width 1 — 17.2cm | 20.1cm |
| Package Width 2 — 35.5cm | 41.3cm |
| Poles Description | 3P |
| Pollution Degree | 3 conforming to IEC 60664-1 |
| Pre-alarm Protection Pick-up Adjustment Range [Ip] | (0.7、0.8、0.9、1.0)xIr |
| Product Certifications | CCC; CB |
| Product Name | UEM5Z1 |
| Product or Component Type | Circuit breaker |
| Range | UEM5Z1 |
| Rated Current (In) | 160 A at 40 °C |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated insulation voltage (Ui) | 800 V AC 50Hz |
| Rated Operational Voltage (Ue) | 400 V AC 50 Hz |
| Rated Service Short-Circuit Breaking Capacity[Ics] | M:50 kA Ics at 400 V AC 50 Hz conforming to IEC 60947-2; H:50 kA Ics at 400 V AC 50 Hz conforming to IEC 60947-2 |
| Rated Ultimate Short-Circuit; Breaking Capacity [Icu] | M:50 kA Icu at 400 V AC 50 Hz conforming to IEC 60947-2; H:70 kA Icu at 400 V AC 50 Hz conforming to IEC 60947-2 |
| Relative humidity | 0…95 %(25℃) |
| Short-Time Protection Delay; Adjustment Range [tsd] | 0.06s、0.1s、0.2s、0.3s |
| Short-Time Protection Delay; Adjustment Type tsd | Adjustable |
| Short-Time Protection Pick-up Adjustment Range[Isd] | (2、3、4、5、6、7、8、10、12) xIr、OFF |
| Short-Time Protection Pick-up Adjustment Type Isd | Adjustable |
| Standards | EN/IEC 60947 |
| Suitability for Isolation | Yes conforming to EN/IEC 60947-2 |
| Trip Unit Protection Functions | LSIP(overload long time delay + short circuit short time delay + short circuit instantaneous + pre-alarm protection) |
| Trip Unit Technology | Thermal-magnetic |
| Unit Type of Package 1 | PCE |
| Unit Type of Package 2 | Box |
| Utilisation Category | Category A |
| Width | 90mm(3P)、120mm(4P) |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for UEM5Z1-160. For a missing document or a specific revision, our experts send it to you.
Hongfa 3-pole 160 A molded case circuit breaker for distribution protection on 400 V AC 50 Hz networks, with LSIP thermal-magnetic trip unit.
| Parameter | Value |
|---|---|
| Ambient Air Temperature for Operation | -25…70 °C |
| Ambient Air Temperature for Storage | -40…70 °C |
| Arcing Distance (mm) | ≤50mm |
| Breaking Capacity | M、H |
| China RoHS Regulation | China RoHS declaration; Product out of China RoHS scope. Substance declaration for your information. |
| Circuit Breaker Mounting Mode | Fixed; Plug-in type |
| Connection Pitch | 30 mm |
| Control type | Operated by handle; Operated by motorized operating mechanism; Operated by rotary operating mechanism |
| Depth | 78 mm |
| Device Application | Distribution |
| Device Short Name | UEM5Z1-160 |
| Electrical Accessory Types | Alarm contact; Shunt release; Auxiliary contact; Undervoltage release |
| Electrical Durability | 1000 cycles at 400 V In |
| Height | 155 mm |
| Instantaneous Protection; Pick-up Adjustment Range [Ii] | (3、4、5、6、7、8、9、10、12) xIn、OFF |
| Instantaneous Protection Pickup Adjustment Type Ii | Adjustable |
| Long-Time Pick-up Adjustment; Type Ir (thermal protection) | Adjustable |
| Long-Time Protection Delay; Adjustment Range [tr] | 12s、60s、80s、100s、OFF |
| Long-Time Protection Delay; Adjustment Type tr | Adjustable |
| Long-Time Protection Pick-up; Adjustment Range [Ir] | 100A、125A、140A、160A |
| Mechanical Durability | 7000 cycles |
| Mounting Position | Horizontal and vertical flat on the back |
| Net weight | 1.6kg(3P)/2.5 kg(4P) |
| Network Frequency | 50 Hz |
| Network type | AC |
| Operating Altitude | 0...2000 m without derating; 2000 m...4000 m with derating |
| Package — 3P | 4P |
| Package Height 1 | 15.6cm |
| Package Height 2 | 33.3cm |
| Package Length 1 — 20.1cm | 20.2cm |
| Package Length 2 — 41.5cm | 41.7cm |
| Package Weight 1 — 1.95kg | 2.89kg |
| Package Weight 2 — 15.6kg | 23kg |
| Package Width 1 — 17.2cm | 20.1cm |
| Package Width 2 — 35.5cm | 41.3cm |
| Poles Description | 3P |
| Pollution Degree | 3 conforming to IEC 60664-1 |
| Pre-alarm Protection Pick-up Adjustment Range [Ip] | (0.7、0.8、0.9、1.0)xIr |
| Product Certifications | CCC; CB |
| Product Name | UEM5Z1 |
| Product or Component Type | Circuit breaker |
| Range | UEM5Z1 |
| Rated Current (In) | 160 A at 40 °C |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated insulation voltage (Ui) | 800 V AC 50Hz |
| Rated Operational Voltage (Ue) | 400 V AC 50 Hz |
| Rated Service Short-Circuit Breaking Capacity[Ics] | M:50 kA Ics at 400 V AC 50 Hz conforming to IEC 60947-2; H:50 kA Ics at 400 V AC 50 Hz conforming to IEC 60947-2 |
| Rated Ultimate Short-Circuit; Breaking Capacity [Icu] | M:50 kA Icu at 400 V AC 50 Hz conforming to IEC 60947-2; H:70 kA Icu at 400 V AC 50 Hz conforming to IEC 60947-2 |
| Relative humidity | 0…95 %(25℃) |
| Short-Time Protection Delay; Adjustment Range [tsd] | 0.06s、0.1s、0.2s、0.3s |
| Short-Time Protection Delay; Adjustment Type tsd | Adjustable |
| Short-Time Protection Pick-up Adjustment Range[Isd] | (2、3、4、5、6、7、8、10、12) xIr、OFF |
| Short-Time Protection Pick-up Adjustment Type Isd | Adjustable |
| Standards | EN/IEC 60947 |
| Suitability for Isolation | Yes conforming to EN/IEC 60947-2 |
| Trip Unit Protection Functions | LSIP(overload long time delay + short circuit short time delay + short circuit instantaneous + pre-alarm protection) |
| Trip Unit Technology | Thermal-magnetic |
| Unit Type of Package 1 | PCE |
| Unit Type of Package 2 | Box |
| Utilisation Category | Category A |
| Width | 90mm(3P)、120mm(4P) |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
3-pole molded case circuit breaker 160 A 50 kA




Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | UEM5Z1-160 |
| Manufacturer | Hongfa |
Molded Case Circuit Breakers
2-pole DC MCCB circuit breaker 320 A DC1500V · Ref. : UEM1E-320
Price on request
Molded Case Circuit Breakers
160 A molded case circuit breaker 3P/4P, 400 V AC · Ref. : UEM5-160
Price on request
Molded Case Circuit Breakers
800 A 3P/4P molded case circuit breaker for distribution
Price on request
Molded Case Circuit Breakers
Molded case circuit breaker 630 A 3P and 4P · Ref. : UEM5-630
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details