UEM5Z1-160 – 3-pole molded case circuit breaker 160 A 50 kA

3-pole molded case circuit breaker 160 A 50 kA

Molded Case Circuit Breakers

  • UEM5Z1
  • 160 A at 40 °C
  • 50 Hz
  • -40…70 °C
Manufacturer part number
UEM5Z1-160
Manufacturer
Hongfa
Range
UEM5Z1
Rated Current (In)
160 A at 40 °C

Hongfa 3-pole 160 A molded case circuit breaker for distribution protection on 400 V AC 50 Hz networks, with LSIP thermal-magnetic trip unit.

Product overview

Hongfa UEM5Z1-160. The UEM5Z1-160 is a 3-pole (3P) molded case circuit breaker (MCCB) from the UEM5Z1 series, intended for distribution on 400 V AC 50 Hz alternating current networks.

Protection. LSIP thermal-magnetic trip unit providing overload long-time delay protection, short-circuit short-time delay protection, short-circuit instantaneous protection and pre-alarm protection. Rated current of 160 A at 40 °C, long-time pick-up Ir adjustable at 100 A, 125 A, 140 A or 160 A, short-time pick-up Isd adjustable from 2 to 12 xIr or OFF, instantaneous pick-up Ii adjustable from 3 to 12 xIn or OFF.

Breaking capacity. Rated service short-circuit breaking capacity Ics of 50 kA at 400 V AC 50 Hz conforming to IEC 60947-2, rated ultimate short-circuit breaking capacity Icu of 50 kA (M version) or 70 kA (H version) at 400 V AC 50 Hz conforming to IEC 60947-2, utilisation category A, suitable for isolation conforming to EN/IEC 60947-2.

Voltage and environment. Rated insulation voltage Ui of 800 V AC 50 Hz, rated impulse withstand voltage Uimp of 8 kV, pollution degree 3 conforming to IEC 60664-1, operating altitude 0 to 2000 m without derating and 2000 m to 4000 m with derating, ambient operating air temperature -25 to 70 °C, relative humidity 0 to 95 % at 25 °C.

Mounting and dimensions. Fixed or plug-in mounting, connection pitch 30 mm, height 155 mm, depth 78 mm, width 90 mm for 3P. Mechanical durability of 7000 cycles and electrical durability of 1000 cycles at 400 V In.

Accessories. Compatible with shunt release, undervoltage release, auxiliary contacts, alarm contact and motorized or rotary operating mechanisms, as listed in the manufacturer documentation.

Available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Ambient Air Temperature for Operation: -25…70 °C
  • Ambient Air Temperature for Storage: -40…70 °C
  • Arcing Distance (mm): ≤50mm
  • Breaking Capacity: M、H
  • Connection Pitch: 30 mm
  • Depth: 78 mm

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote