UEM5Z1-250 – 250 A molded case circuit breaker, 3P and 4P

250 A molded case circuit breaker, 3P and 4P

Molded Case Circuit Breakers

  • UEM5Z1
  • 250 A at 40 °C
  • 50 Hz
  • -40…70 °C
Manufacturer part number
UEM5Z1-250
Manufacturer
Hongfa
Range
UEM5Z1
Rated Current (In)
250 A at 40 °C

Hongfa UEM5Z1-250 molded case circuit breaker rated 250 A for 400 V AC 50 Hz distribution, in 3-pole or 4-pole versions, with adjustable thermal-magnetic protection.

Product overview

Hongfa UEM5Z1-250 molded case circuit breaker — The Hongfa UEM5Z1-250 is a molded case circuit breaker (MCCB) from the UEM5Z1 series, designed to protect alternating current distribution circuits.

Main characteristics. Rated current of 250 A at 40 °C, rated operational voltage of 400 V AC 50 Hz and rated insulation voltage of 800 V AC 50 Hz. The thermal-magnetic trip unit provides LSIP protections: long-time overload, short-time short circuit, instantaneous short circuit and pre-alarm. Settings are adjustable: long-time pick-up Ir from 100 A to 250 A, long-time delay tr from 12 s to OFF, short-time pick-up Isd from 2 to 12 xIr, short-time delay tsd from 0.06 s to 0.3 s, instantaneous pick-up Ii from 3 to 12 xIn, and pre-alarm Ip from 0.7 to 1.0 xIr.

Breaking capacity. Rated ultimate short-circuit breaking capacity Icu of 50 kA (M version) or 70 kA (H version) at 400 V AC 50 Hz conforming to IEC 60947-2. Rated service short-circuit breaking capacity Ics of 50 kA for both versions. Utilisation category A, suitable for isolation conforming to EN/IEC 60947-2.

Accessories and mounting. Fixed or plug-in mounting, in horizontal or vertical flat-on-the-back position. Compatible with shunt release (SHT1), undervoltage release, auxiliary contacts, alarm contact, auxiliary and alarm contact, and motorized and manual operating mechanisms. Available in 3P or 4P, with a width of 105 mm (3P) or 140 mm (4P), a height of 165 mm and a depth of 91 mm.

Environment and durability. Operation from -25 to 70 °C, storage from -40 to 70 °C, operating altitude up to 2000 m without derating. Pollution degree 3 conforming to IEC 60664-1, rated impulse withstand voltage 8 kV. Mechanical endurance of 7000 cycles and electrical endurance of 1000 cycles at 400 V In.

Typical uses. Protection and isolation of low-voltage distribution feeders at 400 V AC 50 Hz, in distribution boards where a 250 A circuit breaker is required.

Available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Ambient Air Temperature for Operation: -25…70 °C
  • Ambient Air Temperature for Storage: -40…70 °C
  • Arcing Distance (mm): ≤50mm
  • Breaking Capacity: M、H
  • Connection Pitch: 35 mm
  • Depth: 91 mm

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.