UEM5-630 – Molded case circuit breaker 630 A 3P and 4P

Molded case circuit breaker 630 A 3P and 4P

Molded Case Circuit Breakers

  • UEM5
  • 50 Hz
  • -40…70 °C
  • 4P
Manufacturer part number
UEM5-630
Manufacturer
Hongfa
Range
UEM5
Network Frequency
50 Hz

The Hongfa UEM5-630 is a 630 A molded case circuit breaker for distribution on 400 V AC networks, in 3-pole or 4-pole versions, with breaking capacities of 35, 50 or 70 kA.

Product overview

Overview. The Hongfa UEM5-630 is a molded case circuit breaker (MCCB) from the UEM5 series, designed for alternating current distribution, in 3P or 4P versions.

Main characteristics. Rated current In of 630 A at 40 °C, with 400 A and 500 A at 40 °C also available in the range. Rated operational voltage Ue of 400 V AC at 50 Hz, rated insulation voltage Ui of 800 V AC and rated impulse withstand voltage Uimp of 8 kV. Three breaking capacity levels (L, M, H): Icu of 35 kA, 50 kA or 70 kA at 400 V AC conforming to IEC 60947-2, with the corresponding Ics for each level. Thermal-magnetic or magnetic trip unit, instantaneous pick-up adjustment between 10 In (power distribution) and 12 In (motor protection). Arcing distance up to 50 mm.

Connection and mounting. Fixed, plug-in or withdrawable mounting modes, with a connection pitch of 44 mm. Control by handle, by motorized operating mechanism or by rotary operating mechanism. Dimensions: 140 mm wide in 3P and 184 mm in 4P, 257 mm high, 97 mm deep. Net weight of 7.5 kg in 3P and 9.6 kg in 4P. Mounting horizontal or vertical flat on the back.

Accessories and electrical functions. Compatible with the shunt release (SHT1), undervoltage release, auxiliary contacts, alarm contact and combined auxiliary and alarm contacts. Isolation suitability conforming to IEC 60947-2, utilisation category A, pollution degree 3 conforming to IEC 60664-1.

Environment and durability. Ambient operating temperature of -25 to 70 °C, storage temperature of -40 to 70 °C, relative humidity of 0 to 95 % (25 °C). Operating altitude of 0 to 2000 m without derating, 2000 to 4000 m with derating. Mechanical durability of 4000 cycles and electrical durability of 1000 cycles at 400 V In. Certifications CCC and CB, standard EN/IEC 60947-2.

Typical use. Protection and isolation of distribution feeders on 400 V AC 50 Hz networks, with the control and signalling accessories listed above for integration into distribution boards. Available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Ambient Air Temperature for Operation: -25…70 °C
  • Ambient Air Temperature for Storage: -40…70 °C
  • Arcing Distance (mm): ≤50mm
  • Breaking Capacity: L、M、H
  • Connection Pitch: 44 mm
  • Depth: 97 mm