UEM5Z1-630
Molded case circuit breaker 630 A for power distribution

- Range
- UEM5Z1
- Rated Current (In)
- 630 A at 40 °C
- Network Frequency
- 50 Hz
- Ambient Air Temperature for Storage
- -40…70 °C
Molded case circuit breaker 630 A for power distribution
Molded case circuit breaker rated 630 A at 400 V AC 50 Hz for electrical distribution, compliant with EN/IEC 60947-2 standards.
Overview. The Hongfa UEM5Z1-630 is a molded case circuit breaker designed for electrical power distribution on AC 50 Hz networks.
Electrical Characteristics. The unit features a rated current of 630 A at 40 °C and a rated operational voltage of 400 V AC 50 Hz. It provides a rated insulation voltage of 800 V AC 50Hz and an impulse withstand voltage of 8 kV.
Protection and Compliance. Featuring thermal-magnetic trip unit technology, this circuit breaker complies with EN/IEC 60947-2 standards in 3P and 4P configurations.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for UEM5Z1-630, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Ambient Air Temperature for Operation | -25…70 °C |
| Ambient Air Temperature for Storage | -40…70 °C |
| Arcing Distance (mm) | ≤50mm |
| Breaking Capacity | M、H |
| China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information. |
| Circuit Breaker Mounting Mode | Fixed; Plug-in type; Withdrawable type |
| Connection Pitch | 44 mm |
| Control type | Operated by handle; Operated by motorized operating mechanism; Operated by rotary operating mechanism |
| Depth | 97 mm |
| Device Application | Distribution |
| Device Short Name | UEM5Z1-630 |
| Electrical Accessory Types | Alarm contact; Shunt release; Auxiliary contact; Undervoltage release |
| Electrical Durability | 1000 cycles at 400 V In |
| Height | 257 mm |
| Instantaneous Protection; Pick-up Adjustment Range [Ii] | (3、4、5、6、7、8、9、10、12) xIn、OFF |
| Instantaneous Protection Pickup Adjustment Type Ii | Adjustable |
| Long-Time Pick-up Adjustment; Type Ir (thermal protection) | Adjustable |
| Long-Time Protection Delay; Adjustment Range [tr] | 12s、60s、80s、100s、OFF |
| Long-Time Protection Delay; Adjustment Type tr | Adjustable |
| Long-Time Protection Pick-up; Adjustment Range [Ir] | 250A、275A、315A、350A、400A、450A、500A、550A、630A |
| Mechanical Durability | 4000 cycles |
| Mounting Position | Horizontal and vertical flat on the back |
| Net weight | 7.3kg(3P)/9.5 kg(4P) |
| Network Frequency | 50 Hz |
| Network type | AC |
| Operating Altitude | 0...2000 m without derating; 2000 m...4000 m with derating |
| Package — 3P | 4P |
| Package Height 1 | 18.5cm |
| Package Height 2 | 19.5cm |
| Package Length 1 | 37.8cm |
| Package Length 2 — 45.5cm | 54.5cm |
| Package Weight 1 — 8kg | 10.25kg |
| Package Weight 2 — 12.72kg | 16.52kg |
| Package Width 1 — 22cm | 26.5cm |
| Package Width 2 | 38.5cm |
| Poles Description | 3P、4P |
| Pollution Degree | 3 conforming to IEC 60664-1 |
| Pre-alarm Protection Pick-up Adjustment Range [Ip] | (0.7、0.8、0.9、1.0)xIr |
| Product Certifications | CCC; CB |
| Product Name | UEM5Z1 |
| Product or Component Type | Circuit breaker |
| Range | UEM5Z1 |
| Rated Current (In) | 630 A at 40 °C |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated insulation voltage (Ui) | 800 V AC 50Hz |
| Rated Operational Voltage (Ue) | 400 V AC 50 Hz |
| Rated Service Short-Circuit Breaking Capacity[Ics] | M:50 kA Ics at 400 V AC 50 Hz conforming to IEC 60947-2; H:70 kA Ics at 400 V AC 50 Hz conforming to IEC 60947-2 |
| Rated Ultimate Short-Circuit; Breaking Capacity [Icu] | M:50 kA Icu at 400 V AC 50 Hz conforming to IEC 60947-2; H:70 kA Icu at 400 V AC 50 Hz conforming to IEC 60947-2 |
| Relative humidity | 0…95 %(25℃) |
| Short-Time Protection Delay; Adjustment Range [tsd] | 0.06s、0.1s、0.2s、0.3s |
| Short-Time Protection Delay; Adjustment Type tsd | Adjustable |
| Short-Time Protection Pick-up Adjustment Range[Isd] | (2、3、4、5、6、7、8、9、10、12) xIr、OFF |
| Short-Time Protection Pick-up Adjustment Type Isd | Adjustable |
| Standards | EN/IEC 60947-2 |
| Suitability for Isolation | Yes conforming to EN/IEC 60947-2 |
| Trip Unit Protection Functions | LSIP(overload long time delay + short circuit short time delay + short circuit instantaneous + pre-alarm protection) |
| Trip Unit Technology | Thermal-magnetic |
| Unit Type of Package 1 | PCE |
| Unit Type of Package 2 | Box |
| Utilisation Category | Category B |
| Width | 140mm(3P)、184mm(4P) |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for UEM5Z1-630. For a missing document or a specific revision, our experts send it to you.
Molded case circuit breaker rated 630 A at 400 V AC 50 Hz for electrical distribution, compliant with EN/IEC 60947-2 standards.
| Parameter | Value |
|---|---|
| Ambient Air Temperature for Operation | -25…70 °C |
| Ambient Air Temperature for Storage | -40…70 °C |
| Arcing Distance (mm) | ≤50mm |
| Breaking Capacity | M、H |
| China RoHS Regulation | China RoHS declaration Product out of China RoHS scope. Substance declaration for your information. |
| Circuit Breaker Mounting Mode | Fixed; Plug-in type; Withdrawable type |
| Connection Pitch | 44 mm |
| Control type | Operated by handle; Operated by motorized operating mechanism; Operated by rotary operating mechanism |
| Depth | 97 mm |
| Device Application | Distribution |
| Device Short Name | UEM5Z1-630 |
| Electrical Accessory Types | Alarm contact; Shunt release; Auxiliary contact; Undervoltage release |
| Electrical Durability | 1000 cycles at 400 V In |
| Height | 257 mm |
| Instantaneous Protection; Pick-up Adjustment Range [Ii] | (3、4、5、6、7、8、9、10、12) xIn、OFF |
| Instantaneous Protection Pickup Adjustment Type Ii | Adjustable |
| Long-Time Pick-up Adjustment; Type Ir (thermal protection) | Adjustable |
| Long-Time Protection Delay; Adjustment Range [tr] | 12s、60s、80s、100s、OFF |
| Long-Time Protection Delay; Adjustment Type tr | Adjustable |
| Long-Time Protection Pick-up; Adjustment Range [Ir] | 250A、275A、315A、350A、400A、450A、500A、550A、630A |
| Mechanical Durability | 4000 cycles |
| Mounting Position | Horizontal and vertical flat on the back |
| Net weight | 7.3kg(3P)/9.5 kg(4P) |
| Network Frequency | 50 Hz |
| Network type | AC |
| Operating Altitude | 0...2000 m without derating; 2000 m...4000 m with derating |
| Package — 3P | 4P |
| Package Height 1 | 18.5cm |
| Package Height 2 | 19.5cm |
| Package Length 1 | 37.8cm |
| Package Length 2 — 45.5cm | 54.5cm |
| Package Weight 1 — 8kg | 10.25kg |
| Package Weight 2 — 12.72kg | 16.52kg |
| Package Width 1 — 22cm | 26.5cm |
| Package Width 2 | 38.5cm |
| Poles Description | 3P、4P |
| Pollution Degree | 3 conforming to IEC 60664-1 |
| Pre-alarm Protection Pick-up Adjustment Range [Ip] | (0.7、0.8、0.9、1.0)xIr |
| Product Certifications | CCC; CB |
| Product Name | UEM5Z1 |
| Product or Component Type | Circuit breaker |
| Range | UEM5Z1 |
| Rated Current (In) | 630 A at 40 °C |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated insulation voltage (Ui) | 800 V AC 50Hz |
| Rated Operational Voltage (Ue) | 400 V AC 50 Hz |
| Rated Service Short-Circuit Breaking Capacity[Ics] | M:50 kA Ics at 400 V AC 50 Hz conforming to IEC 60947-2; H:70 kA Ics at 400 V AC 50 Hz conforming to IEC 60947-2 |
| Rated Ultimate Short-Circuit; Breaking Capacity [Icu] | M:50 kA Icu at 400 V AC 50 Hz conforming to IEC 60947-2; H:70 kA Icu at 400 V AC 50 Hz conforming to IEC 60947-2 |
| Relative humidity | 0…95 %(25℃) |
| Short-Time Protection Delay; Adjustment Range [tsd] | 0.06s、0.1s、0.2s、0.3s |
| Short-Time Protection Delay; Adjustment Type tsd | Adjustable |
| Short-Time Protection Pick-up Adjustment Range[Isd] | (2、3、4、5、6、7、8、9、10、12) xIr、OFF |
| Short-Time Protection Pick-up Adjustment Type Isd | Adjustable |
| Standards | EN/IEC 60947-2 |
| Suitability for Isolation | Yes conforming to EN/IEC 60947-2 |
| Trip Unit Protection Functions | LSIP(overload long time delay + short circuit short time delay + short circuit instantaneous + pre-alarm protection) |
| Trip Unit Technology | Thermal-magnetic |
| Unit Type of Package 1 | PCE |
| Unit Type of Package 2 | Box |
| Utilisation Category | Category B |
| Width | 140mm(3P)、184mm(4P) |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Molded case circuit breaker 630 A for power distribution




Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | UEM5Z1-630 |
| Manufacturer | Hongfa |
Molded Case Circuit Breakers
2-pole DC MCCB circuit breaker 320 A DC1500V · Ref. : UEM1E-320
Price on request
Molded Case Circuit Breakers
160 A molded case circuit breaker 3P/4P, 400 V AC · Ref. : UEM5-160
Price on request
Molded Case Circuit Breakers
800 A 3P/4P molded case circuit breaker for distribution
Price on request
Molded Case Circuit Breakers
Molded case circuit breaker 630 A 3P and 4P · Ref. : UEM5-630
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details