UEM5-400 – Molded case circuit breaker 400 A three-pole and four-pole

Molded case circuit breaker 400 A three-pole and four-pole

Molded Case Circuit Breakers

  • UEM5
  • 50 Hz
  • -40…70 °C
  • 4P
Manufacturer part number
UEM5-400
Manufacturer
Hongfa
Range
UEM5
Network Frequency
50 Hz

The UEM5-400 is a Hongfa molded case circuit breaker rated 400 A for distribution on 400 V AC networks, with selectable operating controls and electrical accessories.

Product overview

Overview. The Hongfa UEM5-400 molded case circuit breaker, from the UEM5 series, is a distribution circuit breaker for AC networks, designed for a 400 V AC 50 Hz network, with a rated current of 400 A at 40 °C and a three-pole (3P) or four-pole (4P) version.

Main characteristics. Three breaking capacity levels are offered: L with 50 kA Icu and 35 kA Ics, M with 65 kA Icu and 50 kA Ics, H with 85 kA Icu and 65 kA Ics, all at 400 V AC 50 Hz conforming to IEC 60947-2. The rated insulation voltage is 800 V AC 50 Hz, the rated impulse withstand voltage 8 kV, and the pollution degree 3 conforming to IEC 60664-1. Tripping is thermal-magnetic or magnetic, with an instantaneous pick-up adjustment of 10 In for power distribution or 12 In for motor protection. Mechanical durability is 4000 cycles and electrical durability 1000 cycles at 400 V In. The device is suitable for isolation conforming to IEC 60947-2 and belongs to utilisation category A.

Accessories and control. The circuit breaker accepts auxiliary contacts, an alarm contact, shunt and undervoltage releases, and can be operated by handle, motorized operating mechanism or rotary operating mechanism. It is available in fixed, plug-in or withdrawable mounting.

Operating environment. Ambient air temperature for operation from -25 to 70 °C, for storage from -40 to 70 °C, relative humidity 0 to 95 % at 25 °C, operating altitude 0 to 2000 m without derating and 2000 to 4000 m with derating. Dimensions are 140 mm wide for 3P and 184 mm for 4P, 257 mm high and 97 mm deep, with a connection pitch of 44 mm. Net weight is 6.2 kg for 3P and 8.0 kg for 4P.

Use and integration. This circuit breaker suits protection and isolation of distribution outgoing feeders in 400 V AC installations. Declared certifications are CCC and CB, and China RoHS compliance is stated through a substance declaration.

See all specifications

Highlights

  • Ambient Air Temperature for Operation: -25…70 °C
  • Ambient Air Temperature for Storage: -40…70 °C
  • Arcing Distance (mm): ≤50mm
  • Breaking Capacity: L、M、H
  • Connection Pitch: 44 mm
  • Depth: 97 mm

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.